20
Drying (Tank 3)
Any items that hold or “cup” any appreciable amount of water should be drained or
blown off via compressed air.
Lower the basket, containing the contents to be dried, into Tank 3.
Do not leave the lid open for extended times and this cause the heaters to remain on
for unnecessary long periods and this can shorten the life of the heater elements.
After the timer has cycled off, open the lid, and remove the contents from the tank.
SPECIFIC CLEANING PROCEDURES
Aluminum Housings
In the ultrasonic bath, preheat 1 part OmegaSupreme with 10 parts clean water to a
temperature of 125
˚F.
Wipe off the readily accessible, exterior excess from the parts to be cleaned.
Arrange the parts so that no trapped air exits in the interior when lowered.
Set the time for 2-5 minutes and start the cleaning cycle.
If additional cleaning is needed, at the end of the first cycle, rotate the parts 180
˚ in
the basket so that the portion that was facing the bottom of the tank is now facing
the top and vice versa.
Clean the parts for another 2-5 minutes.
When completed, rinse the parts with clean, hot water that is 125
˚F.
Blow off excess moisture using compressed air or a hot air blower.