background image

Receiver Operation

8

13

Section 8 - Receiver Operation Cont.

Receiver Operation - UWTC-REC2-D-*-NEMA

Indicator Lights

(1) Transmit (TX) Green Indicator Light 
The top green indicator light marked “TX” on the front of the receiver will 

only blink when the receiver is connected to your PC and you initialize your 

measurement software. After the receiver establishes communication with the 

program the light will no longer blink. Note: this may happen very fast and 

will not be noticeable.
(2) Receive (RX) Red Indicator Light
The red indicator light marked “RX” on the front of the receiver will blink 

each time the receiver receives incoming data from one of your connector 

transmitters.
(3) Standby (SB) Yellow Indicator Light 
The yellow indicator light marked “SB” on the front 

of the receiver will blink continuously during normal 

operation. This indicates that the receiver is in the 

“Standby” mode and is waiting for incoming data from 

your connector/transmitter. 
(4) Power (PWR) Green Indicator Light 

 

 

 

        

Indicator Lights

1

2

SB

PWR

RX

TX

3

4

 

1

2

5

3

  

 

4

6

UWTC-REC2-D-*-NEMA 

(1) Antenna 

(2)  USB NEMA 4X Connector Sealing 

Cap 

(3)  USB NEMA 4X Connector Cable 

(4)  Indicator Lights 

(5)  8 Pin Analog I/O  

 

Waterproof Cable 

 

*: V1, V2, MA Units. 

 

Cable Configuration: 

 

  Green Wire: Analog Output (–) 

 

  White Wire: Analog Output (+) 

 

  Orange Wire: Alarm Power 

 

  Yellow Wire: Alarm Output 

 

  Blue Wire: Digital Ground 

(6)  12 Vdc Power Apaptor

Содержание UWRTD Series

Страница 1: ...used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear...

Страница 2: ...ConnectorTM Wireless Thermocouple RTD Connector Transmitter Receiver e mail info omega com For latest product manuals www omegamanual info Shop online at omega com For complete product manual www ome...

Страница 3: ...1 Introduction 1 Section 2 Product Labels 2 Section 3 Setup Instructions 3 Section 4 Product Labels 5 Section 5 Transmitter Operation 6 Section 6 Connector Operation 7 Section 7 Battery Installation 9...

Страница 4: ...Setup Instructions 3 UWTC UWRTD Setup Procedure 3 1 Install Software 3 2 Install USB Drivers 3 3 Configure Transmitter 3 4 Configure Receiver 4 Section 4 Software 5 Section 5 Transmitter Connector Op...

Страница 5: ...and can transmit simultaneously with your UWTC unit Never install UWTC connector transmitters within 20 cm or less from each other Never install and or operate your UWTC connector transmitter closer...

Страница 6: ...ved including interference that may cause undesired operation FCC ID OUR XBEEPRO IC 4214A XBEEPRO omega com PATENTS PATENTS PENDING F WIRELESS INDUSTRIAL TRANSMITTER 2 4 GHz OMEGA ENGINEERING INC Stam...

Страница 7: ...his is normal You should repeat the steps outlined here twice After the second driver is installed you should then get the New Hardware Ready For Use notice 3 Configure Transmitter Complete the follow...

Страница 8: ...r receivers complete the following procedure Your UWTC REC receiver must be connected to a USB port on your PC a Launch the UWTC REC setup utility program on your PC You can access it through the Prog...

Страница 9: ...g that is being measured by your thermocouple or RTD sensor Ambient This is the actual ambient temperature connector inside the body of your Connector Transmitter If the unit is exposed to temperature...

Страница 10: ...TOR LOW BATT PRESS SETUP PRESS ON OFF UWRTD 3 2 4 1 7 5 6 8 1 RTD WIRING DETAIL 2 3 4 TX UNIVERSAL WIRELESS THERMOCOUPLE CONNECTOR LOW BATT PRESS SETUP PRESS ON OFF UWTC 3 2 4 1 7 5 6 8 1 ON OFF Butto...

Страница 11: ...NB9 UWTC NB9 NEMA UWTC 2 NEMA Thermocouple Version Industrial Probe RTD Versions UWRTD NB9 UWRTD NB9 NEMA UWRTD 2 NEMA RTD Version TC INPUT NOT USED TC INPUT 3 4 5 6 1 2 3 4 5 6 1 2 RTD WIRING DETAIL...

Страница 12: ...will blink one time every 5 seconds 2 Low Battery Low Batt Red Indicator Light The red indicator light marked Low Batt on the front of the connector transmitter will turn on when the battery reaches...

Страница 13: ...o screws that secure the main circuit board from the probe head assembly B Tilt the front of the circuit board just high enough to allow you to unplug the connector that attaches the battery assembly...

Страница 14: ...ce that may cause undesired operation FCC ID OUR XBEEPRO IC 4214A XBEEPRO F 2 3 1 1 2 3 4 5 6 7 8 9 UWTC RPT1 SIDE VIEW ANTENNA USB I O 12 16 Vdc UWTC SERIES WIRELESS TRANSCEIVER OMEGA ENGINEERING INC...

Страница 15: ...de in USA Omega Engineering Inc Stamford CT 06907 4 5 POWER TRANSMIT NETWORK LINK ACTIVITY 6 3 2 2 1 UWTC REC3 1 Antenna 2 Indicator Lights 3 Power LED 4 DC Power Jack 5 Reset 6 Ethernet Connection RJ...

Страница 16: ...device must accept any interference received including interference that may cause undesired operation FCC ID OUR XBEEPRO IC 4214A XBEEPRO 4 UWTC REC1 NEMA 1 Antenna 2 USB NEMA 4X Connector Sealing Ca...

Страница 17: ...nk each time the receiver receives incoming data from one of your connector transmitters 3 Standby SB Yellow Indicator Light The yellow indicator light marked SB on the front of the receiver will blin...

Страница 18: ...3 ANALOG OUTPUT 2 ANALOG OUTPUT 1 ANALOG OUTPUT 4 ANALOG OUTPUT 3 ANALOG OUTPUT 2 ANALOG OUTPUT 1 RX PWR STATUS 1 2 3 4 5 6 7 8 10 9 8 7 6 5 4 3 2 1 Analog Output Connections 1 2 3 4 5 6 7 8 10 9 8 7...

Страница 19: ...A MAX 1N4004 RX PWR STATUS Alarm Example System Powered 1 2 3 4 5 6 7 8 10 9 8 7 6 5 4 3 2 1 12 24 Vdc POWER SUPPLY 0 24 Vdc POWER SUPPLY ALARM RELAY 200 mA MAX 1N4004 RX PWR STATUS Alarm Example Exte...

Страница 20: ...UIRED FOR MAGNETIC RELAYS NOT REQIRED FOR FOR SOLID STATE RELAYS OR MAGNETIC RELAYS WITH INTERNAL DIODE 0 24 VDC POWER SUPPLY 8 7 6 4 5 3 2 1 9 DRIVING A HIGH IMPEDANCE INPUT PULL HIGH DRIVE LOW J4 HI...

Отзывы: