background image

WARRANTY/DISCLAIMER

OMEGA  ENGINEERING,  INC.  warrants  this  unit  to  be  free  of  defects  in  materials  and
workmanship  for  a  period  of 

13  months

from  date  of  purchase.  OMEGA’s  Warranty  adds  an

additional one (1) month grace period to the normal 

one (1) year product warranty

to cover

handling  and  shipping  time.  This  ensures  that  OMEGA’s  customers  receive  maximum
coverage on each product. 

If  the  unit  malfunctions,  it  must  be  returned  to  the  factory  for  evaluation.  OMEGA’s Customer
Service  Department  will  issue  an  Authorized  Return  (AR)  number  immediately  upon  phone  or
written  request.  Upon  examination  by  OMEGA,  if  the  unit  is  found  to  be  defective,  it  will  be
repaired  or  replaced  at  no  charge.  OMEGA’s WARRANTY  does  not  apply  to  defects  resulting
from any action of the purchaser, including but not limited to mishandling, improper interfacing,
operation  outside  of  design  limits,  improper  repair,  or  unauthorized  modification.  This 
WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence
of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibra-
tion;  improper  specification;  misapplication;  misuse  or  other  operating  conditions  outside  of
OMEGA’s control.  Components  which  wear  are  not  warranted,  including  but  not  limited  to
contact points, fuses, and triacs.

OMEGA  is  pleased  to  offer  suggestions  on  the  use  of  its  various  products.  However, 
OMEGA  neither  assumes  responsibility  for  any  omissions  or  errors  nor  assumes  liability
for any damages that result from the use of its products in accordance with information
provided  by  OMEGA,  either  verbal  or  written.  OMEGA  warrants  only  that  the  parts 
manufactured  by  it  will  be  as  specified  and  free  of  defects.  OMEGA  MAKES  NO  OTHER 
WARRANTIES  OR  REPRESENTATIONS  OF  ANY  KIND  WHATSOEVER,  EXPRESS  OR
IMPLIED,  EXCEPT  THAT  OF  TITLE,  AND  ALL  IMPLIED  WARRANTIES  INCLUDING  ANY
WARRANTY  OF  MERCHANTABILITY  AND  FITNESS  FOR  A  PARTICULAR  PURPOSE  ARE
HEREBY  DISCLAIMED.  LIMITATION  OF  LIABILITY:  The  remedies  of  purchaser  set  forth
herein are exclusive, and the total liability of OMEGA with respect to this order, whether
based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall
not exceed the purchase price of the component upon which liability is based. In no event
shall OMEGA be liable for consequential, incidental or special damages.

CONDITIONS:  Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as
a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity;
or (2) in medical applications or used on humans. Should any Product(s) be used in or with any
nuclear  installation  or  activity,  medical  application,  used  on  humans,  or  misused  in  any  way,
OMEGA assumes no responsibility as set forth in our basic WARRANTY/ DISCLAIMER language,
and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability
or damage whatsoever arising out of the use of the Product(s) in such a manner.

RETURN REQUESTS/INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department.
BEFORE  RETURNING  ANY  PRODUCT(S)  TO  OMEGA,  PURCHASER  MUST  OBTAIN  AN
AUTHORIZED  RETURN  (AR)  NUMBER  FROM  OMEGA’S  CUSTOMER  SERVICE  DEPARTMENT
(IN  ORDER  TO  AVOID  PROCESSING  DELAYS).  The  assigned  AR  number  should  then  be
marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to
prevent breakage in transit. 

FOR 

WARRANTY

RETURNS, please have

the following information available BEFORE 
contacting OMEGA:
1. Purchase Order number under which 

the product was PURCHASED,

2. Model and serial number of the product

under warranty, and

3. Repair instructions and/or specific 

problems relative to the product.

FOR 

NON-WARRANTY

REPAIRS, consult

OMEGA for current repair charges. Have the
following information available BEFORE 
contacting OMEGA:
1.  Purchase Order number to cover the COST

of the repair,

2. Model and serial number of the product, and
3. Repair instructions and/or specific problems 

relative to the product.

OMEGA’s  policy  is  to  make  running  changes,  not  model  changes,  whenever  an  improvement  is  possible. 
This affords our customers the latest in technology and engineering.

OMEGA is a registered trademark of OMEGA ENGINEERING, INC.

© Copyright 2010 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without
the prior written consent of OMEGA ENGINEERING, INC.

Содержание RDXL4SD

Страница 1: ...omega com e mail info omega com For latest product manuals omegamanual info User sGuide RDXL4SD 4 Channel Datalogger Thermometer Shop online at MADE IN TAIWAN Extended Warranty Program SM ...

Страница 2: ... Managed by the United Kingdom Office Toll Free 0800 466 342 TEL 33 0 161 37 29 00 FAX 33 0 130 57 54 27 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany Toll Free 0800 6397678 TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29 e mail info omega de United Kingdom OMEGA Engineering Ltd ISO 9001 Certified One Omega Drive River Bend Technology Centre Northbank Irlam Manche...

Страница 3: ... Card Socket 6 4 Measuring Procedure 7 4 1 Type K Measurement 7 4 2 Type J T E R S Measurement 7 4 3 PT 100 Ω Measurement 8 4 4 T1 T2 Measurement 8 4 5 Data Hold 9 4 6 Data Record Max Min Reading 9 4 7 LCD Backlight ON OFF 10 5 Datalogger 10 5 1 Preparation Before Execute Datalogger Function 10 5 2 Auto Datalogger Set Sampling Time 1 Sec 11 5 3 Manual Datalogger Set Sampling Time 0 Sec 12 5 4 Auto...

Страница 4: ...is available set the sampling time to 0 second during execute the manual datalogger function can be set at different positions location position 1 to position 99 Easy operation computer is not needed to setup with software After execute datalogger just take the SD card from the meter and plug in the SD card into a computer It will down load all the measured values with the time information year mo...

Страница 5: ... 0 1 F 1 F Datalogger Auto 1 second to 3600 seconds Sampling Time Sampling time can set to 1 second Setting range but memory data may loss Manual Push the data logger button once will save data one time Set the sampling time to 0 second Manual mode can also select the 1 to 99 position Location no Memory Card SD memory card 1 GB to 16 GB Advanced Set clock time Year Month Date setting Hour Minute S...

Страница 6: ...how Data Hold Freeze the display reading Memory Recall Maximum Minimum value Sampling Time Approx 1 second of Display Data Output RS 232 USB PC computer interface Connect the optional RS232 cable UPCB 02 will get the RS232 plug Connect the optional USB cable USB 01 will get the USB plug Power off Auto shut off saves battery life or manual off by push button Operating 0 to 50 C Temperature Operatin...

Страница 7: ...x 1 9 inch Accessories Instruction Manual Included Optional Accessories USB cable USB 01 RS232 cable UPCB 02 Data Acquisition software SW U801 WIN AC to DC 9V adapter Hard carrying case CA 06 Soft carrying case CA 05A 2 2 Electrical Specifications 23 5 C PT 100 ohm Resolution Range Accuracy 0 1 199 9 to 850 0 C 0 4 1 C 0 1 327 0 to 999 9 F 0 4 1 8 F 1 1000 to 1562 F 0 4 2 F Pt 100 ohm probe TP 101...

Страница 8: ...to 752 0 F 0 4 1 F Type E 0 1 C 50 1 to 100 0 C 0 4 1 C 50 0 to 900 0 C 0 4 0 5 C 0 1 F 58 1 to 148 0 F 0 4 1 8 F 58 0 to 999 9 F 0 4 1 F 1 F 1000 to 1652 F 0 4 2 F Type R 1 C 0 to 600 C 0 5 1 C 601 to 1700 C 0 5 1 C 1 F 32 to 1112 F 0 5 2 F 1113 to 3092 F 0 5 2 F Type S 1 C 0 to 600 C 0 5 1 C 601 to 1500 C 0 5 1 C 1 F 32 to 1112 F 0 5 2 F 1113 to 2732 F 0 5 2 F Remark a Accuracy value is specifie...

Страница 9: ...ton Button R Button 3 7 SET Button Time check Button 3 8 Logger Button OFFSET Button Sampling time check Button 3 9 T1 T2 T3 T4 input socket Type K Type J 3 10 PT1 input socket Pt 100 ohm 3 11 PT2 input socket Pt 100 ohm 3 12 RS 232 output terminal 3 13 DC 9V adapter socket 3 14 Tripod Fix Nut 3 15 Battery Cover Screws 3 16 Battery compartment Cover 3 17 Stand 3 18 SD card socket 6 ...

Страница 10: ... please refer to Chapter 7 5 page 18 3 Insert the Type K probes into the T1 T2 T3 T4 input socket 3 9 Fig 1 The LCD will show the 4 channels T1 T2 T3 T4 temperature value at the same time If the certain channels do not insert the temperature probes the relative channel display will show over range 4 2 Type J T E R S measurement All the measuring procedures are same as the Type K section 4 1 except...

Страница 11: ...nsert a Pt 100 ohm probe to PT1 input socket 3 10 Fig 1 PT2 input socket 3 11 Fig 1 The Pt 100 ohm measurement only allow max two channels two probes input 4 4 T1 T2 measurement When the meter has two installed probes Type K J T E R S T1 T2 input socket Pt 100 ohm PT1 PT2 input socket Pressing the T1 T2 button 3 6 Fig 1 display will show the difference temperature value between T1 T2 PT1 PT2 as T1...

Страница 12: ...s the REC Button 3 4 Fig 1 once the REC MAX symbol along with the maximum value will appear on the display If you wish to delete the maximum value just press the Hold Button 3 3 Fig 1 once the display will show the REC symbol only execute the memory function continuously b Press the REC Button 3 4 Fig 1 again the REC MIN symbol along with the minimum value will appear on the display If you wish to...

Страница 13: ...e SD card should face against the down case b SD card Format If using the SD card for the first time it is recommended to make the SD card Format first Please refer to chapter 7 7 page 19 c Time setting If using the meter for the first time you should adjust the clock time exactly please refer chapter 7 1 page 16 d Decimal format setting The numerical data structure of the SD card is defaulted as ...

Страница 14: ... the beeper sound refer to Chapter 7 4 page 18 b Pause the datalogger During execute the Datalogger function press the Logger Button 3 8 Fig 1 once will pause the Datalogger function stop to save the measuring data into the memory circuit temporally At the same time the text of REC will stop flashing Remark If you press the Logger Button 3 8 Fig 1 once again it will execute the Datalogger again th...

Страница 15: ...ow the Position Location no P1 P2 P99 and the T4 measurement value alternately During execute the Manual Datalogger use the Button 3 5 Fig 1 or Button 3 6 Fig 1 to set the measuring position 1 to 99 for example room 1 to room 99 to identify the measurement location b Finish the Datalogger Press the REC Button 3 4 Fig 1 continuously at least two seconds the REC indication will be disappear and stop...

Страница 16: ...first time to execute the Datalogger under the route TMA01 will generate a new file name TMA01001 XLS After this the Datalogger will save the data to the file TMA01001 XLS until the data column reaches 30 000 columns then it will generate a new file For example TMA01002 XLS 3 Under the folder TMA01 if the total files are greater than 99 files it will generate a new route such as TMA02 4 The file s...

Страница 17: ...e SD card adapter then connect the SD card adapter into the computer 3 Power ON the computer and run the EXCEL software Down load the saving data file for example the file name TMA01001 XLS TMA01002 XLS from the SD card to the computer The saved data will be displayed onto the EXCEL software screen for example as the below EXCEL data screen The user can use EXCEL data to make further Data or Graph...

Страница 18: ... Setting mode Pressing the Next Button 3 3 Fig 1 will in sequence select the seven main functions the lower display will show dAtE Set clock time Year Month Date Hour Minute Second dEC Set SD card Decimal character PoFF Auto power OFF management bEEP Set beeper sound ON OFF t CF Select the Temp unit to or SP t Set sampling time Hour Minute Second Sd F SD memory card Format 15 ...

Страница 19: ...3 5 Fig 1 or Button 3 6 Fig 1 to adjust the value Setting start from Year value After the desired value is set press the Enter Button 3 4 Fig 1 once will go to the next value adjustment for example first setting value is Year then next to adjust Month Date Hour Minute Second value 2 After setting all the time value Year Month Date Hour Minute Second the screen will jump to SD card Decimal characte...

Страница 20: ...oint with default Euro Use as the Decimal point with default 2 After selecting the upper text to bASI or Euro pressing the Enter Button 3 4 Fig 1 will save the setting function with default 7 3 Auto power OFF management When the lower display shows PoFF 1 Use the Button 3 5 Fig 1 or Button 3 6 Fig 1 to select the upper value to yES or no yES Auto Power Off management will enable no Auto Power Off ...

Страница 21: ...ter selecting the upper text to yES or no press the Enter Button 3 4 Fig 1 will save the setting function with default 7 5 Select the Temp unit to C or F When the lower display shows t CF 1 Use the Button 3 5 Fig 1 or Button 3 6 Fig 1 to select the upper Display text to C or F C Temperature unit is C F Temperature unit is F 2 After Display unit is selected to C or F press the Enter Button 3 4 Fig ...

Страница 22: ...r Button 3 4 Fig 1 will save the setting function with default 7 7 SD memory card Format When the lower display shows Sd F 1 Use the Button 3 5 Fig 1 or Button 3 6 Fig 1 to select the upper value to yES or no yES Intend to format the SD memory card no Not execute the SD memory card format 2 If selecting the upper to yES press the Enter Button 3 4 Fig 1 the display will show text yES Ent To confirm...

Страница 23: ...tor appears before the instrument becomes inaccurate 2 Remove the battery cover screws 3 15 Fig 1 and remove the battery cover 3 16 Fig 1 from the instrument and remove the battery 3 Replace with DC 1 5 V battery 6 AA Alkaline heavy duty and replace the cover 4 Make sure the battery cover is secured after changing the batteries 10 RS232 PC SERIAL INTERFACE The instrument has RS232 PC serial interf...

Страница 24: ... D1 D0 Each digit indicates the following status D15 Start Word D14 4 D13 When send the upper display data 1 When send the lower display data 2 D12 D11 Annunciator for Display 01 02 D10 Polarity 0 Positive 1 Negative D9 Decimal Point DP position from right to the left 0 No DP 1 1 DP 2 2 DP 3 3 DP D8 to D1 Display reading D1 LSD D8 MSD For example If the display reading is 1234 then D8 to D1 is 000...

Страница 25: ...3 7 23 7 If no probe is inserted into T1 the meter will measuring adjust display Err value value Use the button 3 5 Fig 1 button 3 6 Fig 1 to adjust the desired value on right bottom display Pressing Enter button 3 4 Fig 1 once the adjustment value will be saved into memory then return to normal measuring screen to finish the offset adjustment procedures The above offset adjustment for Type K J T ...

Страница 26: ... to PT2 input socket Press the R button 3 6 Fig 1 once the display will show example as following SEt oFS 23 7 23 7 If no probe is inserted into PT1 PT2 input measuring adjust socket the meter value value will show Err Use the button 3 5 Fig 1 button 3 6 Fig 1 to adjust the desired value on right bottom display Pressing Enter button 3 4 Fig 1 once the adjustment value will be saved into the memory...

Страница 27: ...se shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should...

Страница 28: ...ine Paddlewheel Systems 䡺 Totalizers Batch Controllers pH CONDUCTIVITY 䡺 pH Electrodes Testers Accessories 䡺 Benchtop Laboratory Meters 䡺 Controllers Calibrators Simulators Pumps 䡺 Industrial pH Conductivity Equipment DATA ACQUISITION 䡺 Data Acquisition Engineering Software 䡺 Communications Based Acquisition Systems 䡺 Plug in Cards for Apple IBM Compatibles 䡺 Data Logging Systems 䡺 Recorders Print...

Отзывы: