OMEGA’s policy is to make running changes, not model changes, whenever an improvement is 

possible. This affords our customers the latest in technology and engineering.
OMEGA is a trademark of OMEGA ENGINEERING, INC.
© Copyright 2018 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, 

photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in 

whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.

WARRANTY/ DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workman-

ship for a period of 

25 months

 from date of purchase. OMEGA’s Warranty adds an additional 

one (1) month grace period to the normal 

two (2) year product warranty

 to cover handling 

and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each 

product. 
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer 

Service Department will issue an Authorized Return (AR) number immediately upon phone or 

written request. Upon examination by OMEGA, if the unit is found to be defective, it will be 

repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting 

from any action of the purchaser, including but not limited to mishandling, improper interfac-

ing, operation outside of design limits, improper repair, or unauthorized modification. This 

WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evi-

dence of having been damaged as a result of excessive corrosion; or current, heat, moisture or 

vibration; improper specification; misapplication; misuse or other operating conditions outside 

of OMEGA’s control. Components in which wear is not warranted, include but are not limited to 

contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However, 

OMEGA neither assumes responsibility for any omissions or errors nor assumes 

liability for any damages that result from the use of its products in accordance with 

information provided by OMEGA, either verbal or written. OMEGA warrants only 

that the parts manufactured by the company will be as specified and free of defects. 

OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND 

WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED 

WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS 

FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: 

The remedies of purchaser set forth herein are exclusive, and the total liability of 

OMEGA with respect to this order, whether based on contract, warranty, negligence, 

indemnification, strict liability or otherwise, shall not exceed the purchase price of 

the component upon which liability is based. In no event shall OMEGA be liable for 

consequential, incidental or special damages.

CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as 

a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; 

or (2) in medical applications or used on humans. Should any Product(s) be used in or with any 

nuclear installation or activity, medical application, used on humans, or misused in any way, 

OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, 

and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability 

or damage whatsoever arising out of the use of the Product(s) in such a manner.

RETURN REQUESTS/ INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. 

BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN 

AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN 

ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on 

the outside of the return package and on any correspondence. The purchaser is responsible for 

shipping charges, freight, insurance and proper packaging to prevent breakage in transit.  

 

Servicing North America:

U.S.A.  

Omega Engineering, Inc. 

Headquarters:  

Toll-Free: 1-800-826-6342 (USA & Canada only) 

 

Customer Service: 1-800-622-2378 (USA & Canada only) 

 

Engineering Service: 1-800-872-9436 (USA & Canada only) 

 

Tel: (203) 359-1660 

Fax: (203) 359-7700 

 

e-mail: [email protected] 

 

 
 

For Other Locations Visit omega.com/worldwide

Содержание OS212-MT

Страница 1: ...OS212 Series Compact Non Contact Temperature Sensor e mail info omega com For latest product manuals omegamanual info Shop online at omega com User sGuide NORWALK CT...

Страница 2: ...pecifications without notice omega com info omega com Servicing North America U S A Omega Engineering Inc Headquarters Toll Free 1 800 826 6342 USA Canada only Customer Service 1 800 622 2378 USA Cana...

Страница 3: ...mm OS802 LT OS802 MT OS802 HT Output 4 20 mA Accuracy 1 of reading or 1 C whichever is greater Repeatability 0 5 of reading or 0 5 C whichever is greater Emissivity 0 2 to 1 0 via 4 20 mA input Respon...

Страница 4: ...icate of calibration Longer cable 30 m max OPTICAL CHART The optical chart below indicates the nominal target spot diameter at any given distance from the sensing head and assumes 90 energy 1000 103 1...

Страница 5: ...clean Electrical Interference To minimise electromagnetic interference or noise the sensor should be mounted away from motors generators and such like Wiring Check the distance between the sensor and...

Страница 6: ...e water cooled housing Water flow rate should not be more than 0 5 to 1 5 litres min 40 0 21 19 63 103 M16 x 1mm 1 8 BSP water air connections 1 8 BSP Air connection 25 OS210 APSW OS212 50 OS210 APSN...

Страница 7: ...steps 1 Turn on the power supply 2 Turn on the meter chart recorder or controller 3 Read monitor the temperature IMPORTANT Be aware of the following when using the sensor If the sensor is exposed to...

Страница 8: ...the table does not help call Omega for further advice Troubleshooting Symptom Probable Cause Solution No output No power to sensor Check power supply Erroneous temperature Incorrect wire connection C...

Страница 9: ...T 30 1 OS302 LT OS302 MT OS302 HT 5mm 100mm OS802 LT OS802 MT OS802 HT Sortie 4 20mA Pr cision 1 de la mesure ou 1 C celui qui est le plus important Fid lit 0 5 de la mesure ou 0 5 C celui qui est le...

Страница 10: ...es Les options sont install es en usine et doivent tre com mand es avec le d tecteur OS212 Series Bo tier refroidi l air eau Certificat de calibrage C ble plus long 30 m max TABLEAU OPTIQUE Le tableau...

Страница 11: ...lentille propre Interf rence lectrique Pour r duire l interf rence lectromagn tique ou bruit le d tecteur devrait tre mont l cart de moteurs g n rateurs et autres appareils similaires C blage V rifie...

Страница 12: ...bo tier refroidi l eau Le d bit d eau ne devrait pas d passer 0 5 1 5 litres min Collier de purge d air Le collier de purge d air ci dessous est utilis pour garder la poussi re les vapeurs l humidit...

Страница 13: ...eur Si le d tecteur est expos des changements significatifs de temp rature ambiante chaud froid ou froid chaud avant de prendre ou d enregistrer des mesures attendre 20 minutes que la temp rature se s...

Страница 14: ...enseignement Diagnostic de d faillances Sympt me Cause probable Solution Pas de sortie Pas d alimentation au d tect eur V rifier l alimentation lec trique Temp rature erron e Connexion incorrecte du c...

Страница 15: ...5mm 100mm OS802 LT OS802 MT OS802 HT Leistung 4 bis 20mA Messunsicherheit 1 des Messwerts oder 1 C je nachdem welcher Wert gr er ist Wiederholgenauigkeit 0 5 desMesswertsoder 0 5 C jenachdem welcherW...

Страница 16: ...it der Installation beginnen vorbereitung Achten Sie darauf dass der Sensor nach dem Aufstellen nur auf das Ziel weist 1000 103 12 18 M16 x 1mm 11 9 45 2 78 6 0 5 1 8 3 1 0 19 7 39 4 0 11 9 0 500 1000...

Страница 17: ...ktromagnetische St rungen oder L rm auf ein Minimum zu reduzieren sollte der Sensor ent fernt von Motoren Generatoren und hnlichen Ger ten aufgestellt werden Verkabelung berpr fen Sie die Entfernung z...

Страница 18: ...mit dem wassergek hlten Geh use einge setzt werden Den Wasserdurchfluss sollte nicht mehr als 0 5 bis 1 5 Liter Min betragen Luftsp lmanschette Die unten abgebildete Luftsp lmanschette h lt Staub D mp...

Страница 19: ...Sensor erheblichen Temperaturschwankungen ausgesetzt wird heiss kalt oder kalt heiss sind 20 Minuten notwendig damit sich die Temperatur vor der Temperaturmessung und aufzeich nung stabilisieren kann...

Страница 20: ...erhilft kann Ihnen Omega m glicherweise telefonisch weitere Tipps geben St rungssuche Symptom Wahrscheinliche Ursache L sung Kein Ausgangssigna Keine Stromzufuhr am Sensor Stromanschluss berpr fen Fal...

Страница 21: ...T 15 1 OS152 LT OS152 MT OS152 HT 30 1 OS302 LT OS302 MT OS302 HT 5mm 100mm OS802 LT OS802 MT OS802 HT Salida 4 a 20mA Precisi n 1 de lectura o 1 C la cifra que sea mayor Repetibilidad 0 5 de lectura...

Страница 22: ...de 30 m CUADRO PTICO El cuadro ptico de debajo indica el di metro nominal del punto de diana a una distancia dada de la cabeza sensora y asume 90 de energ a Sensor MEJOR BUENO INCORRECTO Fondo Diana s...

Страница 23: ...a lente limpia Interferencia el ctrica Para reducir al m nimo la interferencia electromagn tica o el ruido el sensor debe ser instalado alejado de motores generadores o similares Conexiones el ctricas...

Страница 24: ...agua no debe ser superior a 0 5 a 1 5 litros min Aro de purga de aire El aro de purga de aire a continuaci n se usa para mantener el polvo los humos la humedad y otros contaminantes alejados de la len...

Страница 25: ...expone a cambios significativos de temperatura ambiental de caliente a fr o o de fr o a caliente dejar pasar 20 minutos para que la temperatura se estabilice antes de tomar o registrar temperaturas N...

Страница 26: ...lamar a Omega para mayor asistencia Identificaci n de problemas S ntoma Causa probable Soluci n No funciona No hay suministro el ctrico al sensor Comprobar el suministro el ctrico Temperatura err nea...

Страница 27: ...LT OS302 MT OS302 HT 5mm 100mm OS802 LT OS802 MT OS802 HT Uscita da 4 a 20mA Precisione 1 della lettura o 1 C al massimo Ripetibilit 0 5 della lettura o 0 5 C al massimo Coefficiente di emissione reg...

Страница 28: ...e all installazione PREPARAZIONE Assicurarsi che il sensore pirometrico sia posizionato in modo di essere focalizzato sull oggetto di cui si deve misurare la temperatura Sensore OTTIMO BUONO NON CORRE...

Страница 29: ...to per pulire l ottica del sensore INTEEFERENZE ELETTRICHE Per evitare interferenze e disturbi causati dai campi elettromagnetici posizionare il sensore lontano da motori cavi di alta tensione ecc CAB...

Страница 30: ...o si pu usare il collare di pulizia vedi sotto La portata d acqua non deve superare 0 5 a 1 5 litri min COLLARE DI PULIZIA AD ARIA Con questo accessorio tramite il suo manicotto BSP 1 8 si pu insuffla...

Страница 31: ...ore alla tem peratura ambiente di 10 24 C attendere circa 20 minuti per il tempo di stabilizzazione neces sario per avere misure affidabili Non azionare il sensore in prossimit di consistenti campi el...

Страница 32: ...fondito controllo Identificazione dei problemi i Problema Causa probabile Soluzione Manca l uscita Sensore non alimentato Controllo alimentazione Misura non corretta Fili mal collegati Controllo colo...

Страница 33: ...specification misapplication misuse or other operating conditions outside of OMEGA s control Components in which wear is not warranted include but are not limited to contact points fuses and triacs OM...

Страница 34: ...s M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U...

Отзывы: