VIR50-EU-EN-V2.0  9/11 

16 

IR Measurement Notes 

1.  The object under test should be larger than the spot (target) size calculated by the field of view 

diagram (printed on the side of the meter and in this guide). 

2.  Before measuring, be sure to clean surfaces that are covered with frost, oil, grime, etc. 
3.  If an object's surface is highly reflective, apply masking tape or flat black paint to the surface 

before measuring. Allow time for the paint or tape to adjust to the temperature of the surface it is 
covering. 

4.  Measurements through transparent surfaces such as glass may not be accurate. 
5.  Steam, dust, smoke, etc. can obscure measurements. 
6.  The meter automatically compensates for deviations in ambient temperature. However, it can 

take up to 30 minutes for the meter to adjust to extremely wide changes. 

7.  To find a hot spot, aim the meter outside the area of interest then scan across (in an up and 

down motion) until the hot spot is located. 

 

Field of View 

The meter’s lasers converge at a distance of 50 inches (127cm) which is the optimum measurement 
distance for this meter. At this distance the measurement spot has a 1 inch (2.54cm) diameter. The 
Distance to Spot Ratio determines the measured spot size for the distance used. For this meter the 
ratio is 50:1 or: 1”(2.54cm) spot @ 50” (1.27m), 2”(5.08cm) spot @ 100”(2.54m) or 0.5”(1.27cm) 
spot @ 25”(0.64m). 
 
 

50” / 127cm

 

Содержание OS-VIR50

Страница 1: ...OS VIR50 Dual Laser Video IR Video Thermometer e mail info omega com For latest product manuals omegamanual info Shop online at omega com User sGuide MADE IN CHINA ...

Страница 2: ... Managed by the United Kingdom Office Toll Free 0800 466 342 TEL 33 0 161 37 29 00 FAX 33 0 130 57 54 27 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany Toll Free 0800 6397678 TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29 e mail info omega de United Kingdom OMEGA Engineering Ltd ISO 9001 Certified One Omega Drive River Bend Technology Centre Northbank Irlam Manche...

Страница 3: ...nt ergonomic operation This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service Features 2 2 TFT LCD display 640 x 480 pixels Digital Camera Micro SD memory card Image JPEG and video 3gp Humidity and Air Temperature Measurements Dual laser targeting Type K thermocouple probe for contact measuremnts Adjustable emissivity High accuracy Fast respons...

Страница 4: ...B jack Reset button 7 Handle Grip and cover for Micro SD memory card slot and Rechargeable Battery Rear Panel 1 Display 2 and Camera button 3 Power and ESC button 4 ENTER button 5 and Video button Front View 1 Camera lens 2 IR thermometer lens 3 Measurement trigger 4 Battery 5 Battery cover 6 Laser pointers 7 Micro SD card port Note A tripod mount is located on the bottom of the handle 1 2 3 4 5 1...

Страница 5: ...ings wait 30 seconds after powering on to allow the meter to stabilize Measurement Modes The meter has four 4 measurement modes Video Infrared Infrared only Dew Point and Datalogging mode When the meter is switched ON the first screen that appears is the mode selection screen Use the buttons to highlight the desired mode and then press the ENTER button to access the mode Video Infrared mode the me...

Страница 6: ...rature can also be displayed Press and hold trigger to measure the temperature Capturing Still Images Photographs In the Video IR mode press the button to take a photograph Press the button again to save the photo the SAVE soft key will appear above the up arrow button after the photograph is taken Press the button to cancel the photo Capturing Video In the Video IR mode press the button to enter ...

Страница 7: ...tial DIF Temperature and the IR Average AVG Temperature can also be displayed Press and hold trigger to measure the temperature Dew Point Temperature Mode In the Dew Point mode the meter displays the Dew Point temperature measurement along with the IR temperature value Press and hold the measurement trigger to take a measurement In the Dew Point mode the percentage bargraph indicates how close the...

Страница 8: ...he Datalogger screen shown above use the arrow keys to select the HIGH or the LOW alarm value parameter and then press the ENTER button Use the and buttons to adjust the alarm value then press the ENTER button to confirm Set interval time for the datalogger From the Datalogger screen use the arrow keys to select the interval TIME parameter and then press the ENTER button Use the and buttons to adj...

Страница 9: ...om the datalogger mode scroll down to the Measure Set parameter and press ENTER to access to the System Tools setting menu Use the and buttons to select an item and then press the ENTER button to access it Item Description Date Time Set the current date and time Units C F Select the temperature unit of measure Cursor Switch the cursor ON or OFF Backlight Backlight brightness adjustment Auto Power ...

Страница 10: ... and time Setting the temperature units C F Use the and buttons to select the desired unit of measure press the ESC button to exit and save Setting the Cursor style Use the and buttons to select the cursor style off cross or circle press the ESC button to exit and save Setting the Backlight Brightness Use the and buttons to select the backlight brightness level in press the ESC button to exit and ...

Страница 11: ...ve Enable Disable Key press Alert Use the and buttons to enable or disable the key press alert feature press the ESC button to exit and save Memory Status Use the and buttons to select the memory internal flash or SD card Press the ESC button to exit and save If an SD card is inserted in the meter the SD card will be selected by default Press the ENTER button to format the internal flash or SD car...

Страница 12: ...tton again when the middle icon is highlighted to access the Measurement Settings mode as shown below Item Description Emissivity set Set the emissivity Alarm High Set the high alarm ON OFF and set the alarm limit Alarm Low Set the low alarm ON OFF and set the alarm limit Laser Enable or disable the laser pointer Auto Mode Lock the measurement ON MAX MIN Display the highest MAX or lowest MIN IR te...

Страница 13: ...alarm If the high alarm is enabled press the ENTER button to adjust its value use the and buttons to adjust the value Press the ENTER button to conform and then press the ESC button to exit and save Alarm Low Use the and buttons enable or disable the alarm If the low alarm is enabled press the ENTER button to adjust its value use the and buttons to adjust the value Press the ENTER button to confor...

Страница 14: ...the laser ON or OFF Max Min Use the and buttons to set the MAX MIN mode ON or OFF The MAX MIN mode displays the highest MAX and lowest MIN IR temperature Press the ESC button to exit and save Average Dif Use the and buttons to switch ON or OFF the Average or Differential IR temperature Press the ESC button to exit and save Ambient TEMP RH Use the and buttons to switch the air temperature and relat...

Страница 15: ...cess the soft key screen The Memory Settings mode is represented by the icon on the right Use the arrow buttons to scroll over to the right icon if it is not already highlighted Press the ENTER button again when the right icon is highlighted to access the Memory Settings mode Use the and buttons to select Picture Video or Logs and then press the ENTER button to access the selection Use the ENTER b...

Страница 16: ...pty or close to empty recharge the Lithium ion 3 7V 1400mAh rechargeable battery Connect the supplied USB battery cable to the mini USB jack in the compartment above the measurement trigger and then connect the other end of the cable to an AC source Charge time is approx 2 hours The battery is located in the compartment behind the handle panel and beneath the meter s trigger The panel can be relea...

Страница 17: ...not be accurate 5 Steam dust smoke etc can obscure measurements 6 The meter automatically compensates for deviations in ambient temperature However it can take up to 30 minutes for the meter to adjust to extremely wide changes 7 To find a hot spot aim the meter outside the area of interest then scan across in an up and down motion until the hot spot is located Field of View The meter s lasers conv...

Страница 18: ...R50 the emissivity is adjustable from 0 1 to 1 00 see the Measurement Settings section earlier in this User Guide Most organic materials and painted or oxidized surfaces have an emissivity factor of 0 94 When in doubt set the emissivity to 0 94 Emissivity Factors for Common Materials Material under test Emissivity Material under test Emissivity Asphalt 0 90 to 0 98 Cloth black 0 98 Concrete 0 94 S...

Страница 19: ...Field of View D S Approx 50 1 ratio D distance S spot Laser power Less than 1mW Class II Spectral response 8 to 14 μm wavelength Response time 150ms Type K Thermometer Specifications Range Resolution 50 to 1370 o C 58 to 2498 o F 0 1 o C F 1000 1 o C F 1000 0 C to 1370 C 32 F to 2498 F 0 5 2 7 F 1 5 C 50 C to 0 C 58 F to 32 F 2 5C 4 5F Accuracy Note Accuracy is specified for the following ambient ...

Страница 20: ... Max 90 RH non condensing Power Supply 3 7V Lithium ion rechargeable battery Battery life 4 hours continuous approx Battery charge time 2 hours with AC adaptor or USB connection Automatic Power Off Programmable OFF 3 15 and 60 minutes Weight 410g 0 9 lbs Dimensions 205 x 62 x 155mm 8 1 x 2 4 x 6 1 Copyright 2011 Extech Instruments Corporation a FLIR company All rights reserved including the right ...

Страница 21: ...therwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans ...

Страница 22: ...ine Paddlewheel Systems 䡺 Totalizers Batch Controllers pH CONDUCTIVITY 䡺 pH Electrodes Testers Accessories 䡺 Benchtop Laboratory Meters 䡺 Controllers Calibrators Simulators Pumps 䡺 Industrial pH Conductivity Equipment DATA ACQUISITION 䡺 Data Acquisition Engineering Software 䡺 Communications Based Acquisition Systems 䡺 Plug in Cards for Apple IBM Compatibles 䡺 Data Logging Systems 䡺 Recorders Print...

Отзывы: