OPERATIONAL INFORMATION
3
OPERATIONAL INFORMATION
Installation Instructions
Power Requirements: Voltage and frequency of power supply must be
the same as shown on unit.
Wiring Connections: All wiring and electrical connections must comply
with national electrical codes and local electrical codes.
Mounting:
a) Mount OEM model mounting bracket to any flat, rigid surface, using
four #10-32 screws.
b) Case enclosed model may be placed on any flat surface, assuring
space is provided at the back of the case for air circulation through
ventilation holes.
Mounting Location: Pump should be used in a dry location with an
adequate supply of cooling air. The ambient temperature should not
exceed 25°C.
This unit should not be used outdoors or in hazardous
locations.
Instructions for Optional Timer
1. Rotate the program disc in the direction of the arrows to align the
correct time of day with the time mark.
2. Set the desired switching program by pushing the switch actuators
toward the center of the time switch. Each actuator provides a 15
minute “ON” time. The now visible orange area(s) indicate the
switch “ON” period
WARNING