OM-USB-TEMP-AI User's Guide
Specifications
24
Compatible sensors: T0x-T3x
Table 3. Compatible sensor type specifications
Parameter
Conditions
J: -210 °C to 1200 °C
K: -270 °C to 1372 °C
R: -50 °C to 1768 °C
S: -50 °C to 1768 °C
T: -270 °C to 400 °C
N: -270 °C to 1300 °C
E: -270 °C to 1000 °C
Thermocouple
B: 0 °C to 1820 °C
100 ohm PT (DIN 43760: 0.00385 ohms/ohm/°C)
100 ohm PT (SAMA: 0.003911 ohms/ohm/°C)
RTD
100 ohm PT (ITS-90/IEC751:0.0038505 ohms/ohm/°C)
Thermistor
Standard 2,252 ohm through 30,000 ohm
Semiconductor / IC
TMP36 or equivalent
Accuracy
Thermocouple measurement accuracy: T0x-T3x
Table 4. Thermocouple accuracy specifications, including CJC measurement error. All specifications are (±).
Sensor
Type
Sensor temperature
range
Accuracy error
maximum
(°C)
Accuracy error
typical
(°C)
Tempco
(°C/°C)
-210 °C
2.028
0.707
0 °C
0.835
0.278
J
1200 °C
0.783
0.288
0.031
-210 °C
2.137
0.762
0 °C
0.842
0.280
K
1372 °C
0.931
0.389
0.035
-50 °C
1.225
0.435
250 °C
0.554
0.195
S
1768 °C
0.480
0.157
0.021
-50 °C
1.301
0.458
250 °C
0.549
0.190
R
1768 °C
0.400
0.134
0.019
250 °C
2.193
2.185
700 °C
0.822
0.819
B
1820 °C
0.469
0.468
0.001
-200 °C
1.976
0.684
0 °C
0.954
0.321
E
1000 °C
0.653
0.240
0.030
-200 °C
2.082
0.744
0 °C
0.870
0.290
T
400 °C
0.568
0.208
0.035
-200 °C
2.197
0.760
N
0 °C
0.848
0.283
0.028
1300 °C
0.653
0.245