background image

  

Minimum

Typical

Maximum

Unit

Battery life

>1*

Year

USB supply voltage

4.5v

5.5v

V d.c.

Temperature measurement range

-20 (-4)

+60 (+140)

°C (°F)

Internal resolution

+/- 0.5

°C

Temperature accuracy (overall error between -10°C and +60°C)

+/- 1.0

°C

Humidity accuracy (overall error between 20%RH and 80%RH)

+/- 3.0

%RH

Every 10s

30 seconds

Every 12hrs

Transmisson rate

Operating temperature range

-20 (-4)

+60 (+140)

°C (°F)

*

 Typical but will be less if frequent transmissions

    

Warning - do not exceed operating temperatures

EXAMPLE OF UNIT WHILE PHYSICALLY CONNECTED TO PC DURING SET-UP

PHYSICAL DIMENSIONS

All dimensions in millimetres (mm)

HARDWARE

• Bat

tery: Rechargeable via USB connection.

• ARM MC

U.

• 1x mic

roUSB Type B (bottom of unit) for connection of unit to PC. 0.5m USB cable supplied.

The sensor clips into the bracket.

All OM--EL-WiFi-TH sensors are thoroughly tested pre-release but the sensor may experience compatibility issues with certain WiFi 
networks. In this instance we recommend the use of network accessories available on the Omega website.

www.omega.com

 

    

Содержание OM-EL-WiFi-TH

Страница 1: ...e mail info omega com For latest product manuals omegamanual info OM EL WiFi TH Temperature Humidity Data Logger Extended Warranty Program SM Shop online at omega com User sGuide...

Страница 2: ...Managed by the United Kingdom Office Toll Free 0800 466 342 TEL 33 0 161 37 29 00 FAX 33 0 130 57 54 27 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany Toll Free...

Страница 3: ...rging The software installed on the PC will allow set up data logging and data review Set up features will include sensor name C F sample rate and high low alarms Once configured historic data can be...

Страница 4: ...requent transmissions Warning do not exceed operating temperatures EXAMPLE OF UNIT WHILE PHYSICALLY CONNECTED TO PC DURING SET UP PHYSICAL DIMENSIONS All dimensions in millimetres mm HARDWARE Battery...

Страница 5: ...olding the button for 3 seconds will clear the stored values The sensor can be restarted by holding the button for 10 seconds until the screen blanks and LOW is shown flashing in the top right hand co...

Страница 6: ...therwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Страница 7: ...ity Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial...

Отзывы: