Omega OM-93 Скачать руководство пользователя страница 38

WARRANTY/DISCLAIMER

 

OMEGA  ENGINEERING, INC. warrants   this  unit  to  be  free  of  defects  in  materials   and  workmanship for a 
period  of 

13   months  

from   date  of  purchase.  OMEGA’s  WARRANTY  adds  an  additional  one (1) month 

grace  period  to  the  normal  

one  (1)  year  product warranty 

to cover handling  and shipping  time.  This 

ensures that OMEGA’s customers  receive maximum coverage on each product.

 

If the unit  malfunctions,  it  must   be  returned   to  the  factory   for  evaluation.  OMEGA’s  Customer   Service 
Department   will   issue  an  Authorized  Return  (AR)  number   immediately  upon   phone  or  written  request. 
Upon  examination  by  OMEGA,  if  the  unit  is  found  to  be  defective,   it  will   be  repaired   or  replaced  at  no 
charge.  OMEGA’s  WARRANTY  does  not  apply   to  defects  resulting   from   any  action   of  the  purchaser, 
including   but   not   limited   to  mishandling,  improper   interfacing,  operation   outside   of  design   limits, 
improper  repair,  or  unauthorized modification.  This  WARRANTY  is  VOID  if  the  unit   shows   evidence   of 
having  been tampered  with  or  shows  evidence  of  having  been damaged  as a result  of  excessive  corrosion; 
or  current,   heat,  moisture   or  vibration;   improper   specification; misapplication;  misuse  or  other  operating 
conditions   outside  of  OMEGA’s  control.   Components  in  which  wear  is  not  warranted,   include  but  are  not 
limited to contact points,  fuses, and triacs.

 

OMEGA   is   pleased    to   offer    suggestions  on   the   use   of   its   various    products.  However, 
OMEGA neither  assumes   responsibility  for   any  omissions   or  errors   nor   assumes   liability for 
any  damages   that   result   from   the  use  of  its  products  in  accordance with   information  provided 
by  OMEGA, either   verbal   or  written. OMEGA warrants only  that   the  parts   manufactured  by  the 
company  will   be  as  specified  and free  of defects. OMEGA MAKES NO OTHER WARRANTIES  OR 
REPRESENTATIONS  OF  ANY   KIND   WHATSOEVER, EXPRESSED OR  IMPLIED,  EXCEPT   THAT   OF 
TITLE,   AND   ALL  IMPLIED   WARRANTIES INCLUDING  ANY   WARRANTY  OF  MERCHANTABILITY 
AND   FITNESS   FOR A PARTICULAR  PURPOSE   ARE HEREBY  DISCLAIMED. LIMITATION OF 
LIABILITY:  The  remedies  of  purchaser  set  forth  herein   are  exclusive,  and  the   total liability of 
OMEGA  with   respect  to  this  order,   whether  based  on  contract, warranty, negligence, 
indemnification,  strict  liability  or  otherwise,  shall  not  exceed   the  purchase  price   of  the 
component   upon    which  liability   is   based.     In   no   event     shall   OMEGA    be   liable     for 
consequential, incidental or special  damages.

 

CONDITIONS:  Equipment sold by OMEGA is not intended  to be used, nor shall it be used: (1) as a “Basic 
Component” under 10 CFR  21 (NRC), used in or with  any nuclear installation or activity;  or (2) in medical 
applications  or used on humans.  Should  any Product(s)  be used in or with  any nuclear  installation  or 
activity,   medical  application, used  on  humans,  or  misused  in  any  way,  OMEGA assumes  no  responsibility 
as set  forth   in  our  basic  WARRANTY/DISCLAIMER  language,   and,  additionally,  purchaser   will   indemnify 
OMEGA and hold  OMEGA harmless  from  any liability or  damage  whatsoever  arising  out  of  the  use of  the 
Product(s) in such a manner.

 

 

 

RETURN  REQUESTS/INQUIRIES

 

Direct   all   warranty   and   repair   requests/inquiries   to   the   OMEGA  Customer   Service   Department. 
BEFORE RETURNING ANY  PRODUCT(S) TO OMEGA, PURCHASER MUST  OBTAIN AN AUTHORIZED 
RETURN (AR) NUMBER FROM OMEGA’S  CUSTOMER SERVICE  DEPARTMENT (IN  ORDER TO AVOID 
PROCESSING  DELAYS). The  assigned  AR  number   should  then  be marked  on the outside  of the return 
package and on any correspondence.

 

The purchaser  is responsible  for  shipping  charges,  freight,  insurance  and proper  packaging  to prevent 
breakage in transit.

 

FOR 

 WARRANTY 

RETURNS, please  have  the 

following information available  BEFORE contacting 
OMEGA:

 

1. Purchase Order number under which the product 

was PURCHASED,

 

2.  Model  and  serial  number  of  the  product  under 

warranty,  and

 

3. Repair instructions and/or specific problems 

relative to the product.

 

FOR 

NON-WARRANTY 

REPAIRS, consult

 

OMEGA for current  repair  charges. Have

 

the  following information available  BEFORE

 

contacting  OMEGA:

 

1.  Purchase Order number  to cover the COST

 

of the repair,

 

2.  Model  and  serial  number  of  the  product,  and

 

3. Repair instructions and/or specific problems 

relative to the product.

 

OMEGA’s  policy   is  to  make  running   changes,  not  model   changes,  whenever   an  improvement  is possible.  This affords 
our customers  the latest in technology and  engineering.

 

OMEGA is a registered  trademark  of  OMEGA ENGINEERING, INC.

 

© Copyright  2016 OMEGA ENGINEERING, INC. All  rights   reserved.   This  document   may  not  be  copied,   photocopied, 
reproduced,  translated,   or  reduced  to  any  electronic   medium   or  machine-readable   form,   in  whole   or  in  part,  without  the 
prior written  consent of OMEGA ENGINEERING, INC.

 

Содержание OM-93

Страница 1: ...xtended Warranty Program User sGuide Shop online at omega com e mail info omega com For latest product manuals www omegamanual info OM 93 OMEGA Bluetooth Wireless Temperature Humidity Data Logger M5543 0216 ...

Страница 2: ... 359 7700 e mail info omega com For Other Locations Visit omega com worldwide The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of such marks by Omega Engineering Inc is under license Other trademarks and trade names are those of their respective owners iPhone iPad and iPad mini are trademarks of Apple Inc registered in the U S and other countries W...

Страница 3: ...ration of a OM 93 Logger Start at Specified Time 18 6 10 Configuration of a OM 93 Logger Start using Button Press 19 6 11 Configuration of a OM 93 Logger Real Time Logging 20 6 12 Opening Excel 21 6 13 Writing PDF reports 22 7 iPhone Operation 24 7 1 Installation of the iPhone Application 24 7 2 Searching for OM 93 loggers 25 7 3 Connecting to your logger 25 7 4 Configuring the logger 27 7 5 Downl...

Страница 4: ...cation for the logger how to use the PC application for configuration data extraction and data viewing how to install the iPhone Application how to use the iPhone application for configuration data extraction and data viewing how to mount your OM 93 logger how to charge the battery within your OM 93 logger contact information should you have further technical questions ...

Страница 5: ...and data viewing features Figure 1 Introducing the Omega OM 93 Logger PC and iPhone applications The OM 93 logger can be used for a number of transportation applications including sensitive fragile items food animal livestock plants chemicals medicines or organs It can also be used in situations where it is simply not convenient to make a cable connection to a Windows PC Suppose for example you ar...

Страница 6: ...ither by connection to USB on a computer or using a mains USB power cable The OM 93 offers accurate and repeatable logging for temperature and relative humidity Temperature is measured to an accuracy of 0 3o C over the range 5o C to 60o C Over the full range 20o C to 60o C the accuracy is 2 0o C Relative humidity is measured to an accuracy of 2 0 over 20 to 80 humidity range and 3 0 over 0 to 100 ...

Страница 7: ...elative humidity accuracy 0 to 100 see accuracy curve in figure 3 Relative humidity resolution 0 1 Temperature alarms minimum maximum Relative humidity alarms minimum maximum Battery Rechargeable LiPo Battery life 6 months before needing recharging Physical size 50mm x 68mm x 20mm PC application available on Windows XP Vista Windows 7 Windows 8 and Mac Mobile application supported on iPhone iPad a...

Страница 8: ...following functionality Status LED When the logger starts logging then this LED pulses green once for 1 second When logging this LED pulses green for 7 milliseconds and off for 6 seconds When the logger stops then this LED pulses red for 1 second then off forever Bluetooth Connected LED This LED is blue when the logger is connected to a mobile device Alarm LED When a temperature or humidity alarm ...

Страница 9: ...ion 1 0 3 Page 7 5 Packaging List Your Omega OM 93 logger comes standard with the following items One OM 93 Logger unit Figure 6 OM 93 Logger Unit One USB cable type A to micro USB type B Figure 7 USB Cable ...

Страница 10: ...device application as described in section 7 6 1 Installation of the PC Application Windows Installation of the OM 90 Series Data Logger Software is very simple The OM 93 needs no special drivers since it is a USB HID device and such devices can make use of the standard drivers that come with Windows The software is located on the included CD or can be downloaded from the Omega website The PC appl...

Страница 11: ...ntroduction to the OM 90 Series loggers and what they can be used for Click on the Configuration Wizard Button to start configuration of the logger Click on the View Logged Button if you want to view data graphically Click on the View Spreadsheet Button if you want to view logger data as a table Figure 8 OM 90 Series Data Logger Software ...

Страница 12: ...n the viewing mode select from the front page Figure 9 PC Application Main Page Buttons are also included for saving loading configuration and logged data to and from file There is also a button for selection between Celsius or Fahrenheit temperature scales A connection indication on the right hand side becomes blue when your application is connected to a OM 93 logger and is greyed out otherwise I...

Страница 13: ...ger start to On Disconnection There are other options At Specified Time Button Press and Real Time Logging which will be discussed in later sections of this manual Select the logging interval this is the time between samples For temperature logging then one needs to enable or disable the logging In the case the temperature logging is enabled then one can also set alarm thresholds for which the ala...

Страница 14: ...ger time will be synchronized to the PC time The logger firmware revision will also appear in the application Once you disconnect the logger from the PC logging will start automatically and at the configured logging interval A green status LED will flash every 6 seconds to indicate that the unit is logging The red alarm LED will flash also in the case that the temperature or humidity goes outside ...

Страница 15: ...e multiple devices with the same configuration Saving a configuration file is just a matter of selecting the save icon and filling out the file name If the logger contains no logged data then it will only save the configuration settings Configuration and logged data is stored in Comma Separated Value CSV format Figure 12 Saving a Configuration to File ...

Страница 16: ...ation file name This upload presents a simple way to configure multiple loggers with the same configuration This ensures a common configuration and saves time effort when configuring multiple devices Figure 13 Loading a Configuration from File Remember to press the configuration button if you want the configuration data held in the GUI to be written to your OM 93 logger ...

Страница 17: ...d out of the graphs can be achieved by the following controls To Zoom In Drag the left mouse button To Zoom Out Click the right mouse button When zoomed in you can move around using the key board arrows or the mouse scroll wheel To write data and configuration to file press the save icon Data and configuration is then stored in Comma Separated Value CSV format which can be edited by third party so...

Страница 18: ... is a simple matter to read back data from file CSV format into the GUI and view previous logs graphically or using the spreadsheet views Simply press the open icon and then select the file which you would like to view Figure 15 Retrieving Logged Data from File ...

Страница 19: ...Revision 1 0 3 Page 17 Figure 16 Retrieving Logged Data from File complete ...

Страница 20: ...xact month day hour minute and seconds when you want the logging to start Remember to write the setup to the logger by pressing the Configure Button When you have disconnected the logger and the time reaches the desired start time for the logging then the logger will begin to log This is a perfect way to have multiple loggers start logging at exactly the same time Figure 17 Configuration Step Star...

Страница 21: ...select Button Press Remember to write the setup to the logger by pressing the Configure Button When you have disconnected the logger you can start logging by a simple button press You will then see it is logging because the green light starts flashing every 6 seconds You can also stop it using a button press and all lights will stop flashing Figure 18 Configuration Step Start using Button Press ...

Страница 22: ...ing to Real Time Logging with the appropriate logging interval Next press start You will then see the PC application take samples from the logger directly and display them on the table and graphs This is a way to monitor temperature and humidity conditions directly from your PC instead of using the remote logging Figure 19 Configuration Step Real Time Logging ...

Страница 23: ... Excel During this process the user needs to select if your version of Excel is expecting and or to represent the number decimal point This capability assumes that Microsoft Excel is installed on your PC If not then the option will not work This option is not available on the Mac version of the GUI Figure 21 Opening Excel from the GUI ...

Страница 24: ... to summarize the data in the logger by way of statistics and as a graph The PDF can be written either in US Letter page size of A4 page size The user can enter one s own notes at the footer of the PDF PDFs are written to file and can be opened by any standard PDF reader Figure 22 Writing a PDF report from the GUI ...

Страница 25: ...Revision 1 0 3 Page 23 Figure 23 A typical PDF report ...

Страница 26: ...ng the OM 93 iPhone application This process is described in this section The logger can similarly be configured by a Windows PC as described in section 6 7 1 Installation of the iPhone Application The OM 93 iPhone Application is a free app found on Apple s App Store Search for Omega OM 93 Application Find it and download the application Figure 20 OM 93 iPhone App on Apple s App Store ...

Страница 27: ...an option of scanning for all OM 93 loggers Figure 21 OM 93 iPhone App Searching 7 3 Connecting to your logger After searching the application will provide a list of all OM 93 devices that can be connected from your mobile device See figure 22 Select one of the devices within range The first time the iPhone application discovers a OM 93 logger it will mark it as undiscovered Upon connecting and th...

Страница 28: ...evice Upon successful connection the logger s Bluetooth Connected LED turns blue On the application the connected icon turns green Also the application starts showing in real time the temperature and humidity from the logger Figure 23 OM 93 iPhone App Logger Connected ...

Страница 29: ...of the logger the logging start mode o on disconnection o by button press o at specified start time the logging interval enabling disabling of temperature logging enabling disabling of humidity logging temperature units Fahrenheit or Celsius temperature alarms levels upper and lower humidity alarms levels upper and lower Once all configuration is as required then press send to download all setting...

Страница 30: ...to a logger that has collected data then to download the data select Download Logger from the Connected screen The application then moves to the Data screen and all data appears as a list of all sample points collected Figure 26 OM 93 iPhone App Downloading Data ...

Страница 31: ...d Once data is read into the application it is possible to view the data graphically from the Graph screen Zooming is controlled by finger movement Apple s usual pinch out to zoom in and pinch in to zoom out Figure 27 OM 93 iPhone App Graphing Data ...

Страница 32: ... iPhone from the Data screen Select the option to the top of the application and then select Save to File You will then be prompted for the file name This saves data to the phone in case there is no Wifi or Cellular connection Figure 28 OM 93 iPhone App Saving Data to the iPhone ...

Страница 33: ...8 Opening data from the iPhone You can read data back from the iPhone to the application Select the option to the top of the application and then select Open from File Figure 29 OM 93 iPhone App Retrieving Data from the iPhone ...

Страница 34: ...Revision 1 0 3 Page 32 To delete from the file list swipe left on the desired file Figure 30 OM 93 iPhone App Deleting a stored file ...

Страница 35: ... iPhone application Select the option to the top of the application and then select Send to e mail Please note that in order for the application to use the emailing function your iPhone or iPad will need to be setup with at least one email account Figure 31 OM 93 iPhone App Emailing Data ...

Страница 36: ...r either select Disconnect on the Connected screen or just close the application The Blue LED will turn off indicating the logger disconnected state Having the application sent to the background is also sufficient to close connection to the logger Figure 32 OM 93 iPhone App Disconnection ...

Страница 37: ... loosely packed It is recommended however to keep some air space around the ventilation slots on the logger or else the logger may take longer to track humidity and temperature changes 10 Battery Charging Your Omega OM 93 logger includes a Lithium Polymer LiPo rechargeable battery The Battery automatically charges by connection to any USB source such as a PC or Mac It is also possible to charge us...

Страница 38: ...otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans...

Страница 39: ...tors Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH Conductivity Equipment DATA ACQUISITION Data Acquisition Engineering Software Communications Based Acquisition Systems Plug in Cards for Apple IBM Compatibles Data Logging Systems Recorders Printers Plotter...