manualshive.com logo in svg
background image

 

ELECTRICAL CONNECTIONS 

LOCAL AUTHORITY REQUIREMENTS 

Installation is only permitted by an authorized person, and carried out according to instructions provided by 

the manufacturer.  Incorrect installation might cause harm and damage which the manufacturer accepts no 

responsibility.  The electrical connection can be found 30mm in from the rear edge and 280mm from the left 

hand side (looking from the front). 

INSTALLATION 

This cooktop must be connected to a 220-240V 50Hz power supply. It is earthed via the cord. 

Before carrying out the connection to the power supply, the voltage rating of the appliance (stamped on the 

appliance identification plate) must be checked for correspondence to the available mains supply voltage, 

and the mains electric wiring should be capable of handling the hob’s power rating (also indicated on the 

identification plate); 

The power point must be connected to a suitable earth wiring, in conformity to current safety regulations. 

Ensure that the power supply is within 900mm of the cooktop. The power supply cord must not touch 

against any hot surfaces and must be placed so that its temperature does not exceed 75 degrees C at any 

point along its length. 

The colours of the wires in the hob power cable may not correspond with the colours marked on the 

terminals of your electrical plug .The plug should in any case be wired as follows:   

—connect the green/yellow wire to the terminal marked with the letter E or the earth symbol or coloured 

green/yellow; 

—connect the blue wire to the terminal marked with the letter N or 

coloured black; 

—connect the brown wire to the terminal marked with the letter L 

or coloured red.

 

After having installed the appliance, the power switch or power plug 

must always be in an accessible position. 
 

 Electrical connection diagram    

 

N.B For connections to the mains power supply, never use adapters, reductions or multiple power points as 

these may overheat and catch fire. 

In the event that installation should require modifications to the mains supply wiring system or if the power 

plug is not suitable for the type of power point available, it is required that a qualified technician be called to 

carry out substitution. 

The technician will also have to verify that the cross-section of the electric cables on the power point match 

the appliance’s power rating.   

 

INSTALLATION 

Note

: These tops are designed to be fitted into kitchen fixtures measuring 600 mm in depth.    

In order to install the cooker top into the kitchen fixture, a hole with the dimensions shown on the cutting size 

board has to be made, keeping in consideration the following: 

Within the fixture, between the bottom side of the cooker top and the 

upper surface of any other appliance or internal shelf there must be a 

clearance of at least 30 mm;  

Keep at least 200mm from the periphery of the burners to any side or 

rear wall with combustible surfaces or keep the appliance sides at least 

50mm from walls with non-combustible surfaces. 

There must be a distance of at least 650 mm between the hob and any 

extractor hood or wall cupboard positioned immediately above it. The 

distance to an overhead exhaust fan must be at least 750mm. 

The duplicate data plate should be fixed in an accessible position close 

to the appliance (inside face of cupboard door, side of cabinet etc). 

Note:

 Keep a safe distance away from combustible constructions.   

After installation, all burners should be tested individually and together to 

ensure correct operation. 

 

Содержание OCG905FX

Страница 1: ...INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS Gas Cooktop OCG905FX...

Страница 2: ......

Страница 3: ...avoid misuse and hazards It is important that you retain these instructions and your proof of purchase along with any other important documents about this product for future reference Due to continua...

Страница 4: ...lation it must be replaced by the manufacturer it s service agent or similarly qualified persons in order to prevent a hazard 7 The electrical and gas connections must be accessible after installation...

Страница 5: ...on the front face e g 1 8 for 1 80mm injector Semi rapid Burner Rapid Burner Wok Burner Auxiliary Burner Semi rapid Burner Table of recommended pot sizes for each burner type Control Knob functions a...

Страница 6: ...and one gasket fitted between the inlet and elbow The hob must be installed in a room with adequate ventilation see installation section N G Fit the supplied NG regulator to the elbow fitting using t...

Страница 7: ...a test point REGULATING THE BURNER MINIMUM SETTING When switching from one type of gas to another the minimum flow rate must also be correct The flame should not go out even when passing suddenly fro...

Страница 8: ...r coloured red After having installed the appliance the power switch or power plug must always be in an accessible position Electrical connection diagram N B For connections to the mains power supply...

Страница 9: ...an underneath the hob is forbidden PREPARING PLACING THE HOB FOR INSTALLATION Every cooker top is provided with a set of tabs for fitting to the unit with thickness from 3 to 4 cm and a seal with adhe...

Страница 10: ...rature This will speed up the cooking time and is more efficient In the event of a power outage your gas cooktop can still be used Press turn the desired knob to the High position and light with a mat...

Страница 11: ...pipes should be checked periodically for leakages see section on leak testing a minimum of every 12 months Lubrication of gas valves This can only be performed by an authorised person It may be requi...

Страница 12: ...2018 10 15...

Отзывы: