background image

 

CHECKING THE BURNER PRESSURE 

Natural Gas (the appliance test point is located at 
the regulator). The supplied regulator must be fitted 
to the appliance inlet connection. The gas pressure 
must be adjusted to 1.0kPa when approximately 
50% of the burners are on high.

 

 

 
Universal LPG (the appliance test point is 
located at the injector). The gas pressure 
must be checked to confirm the appliance 
operating pressure is 2.75kPa. The appliance 
test point is the rapid burner injector. 
1. Disconnect the electrical power.

 

 

2. Light the auxiliary burner and set to high. 
Make sure all other burners are off. 
3. Zero the manometer, fix the flexible tubing 
to seal around the rapid burner injector and 
hold in place. Check the gas pressure by 
pressure by pressing in the corresponding 
burner control knob down and turning to the high position. 
4. If the pressure is 2.75kPa, reassemble the burner and perform the final checks as per this manual. 
5. If the pressure is not 2.75 kPa, disconnect the appliance and check/adjust/replace the ULPG cylinder 
regulator(s) as appropriate in accordance with AS/NZS 5601. 
Alternatively, if the appliance is supplied with a ULPG test point adapter, then this can be fitted to the inlet 
connection for the purpose of a test point. 

 

REGULATING THE BURNER MINIMUM SETTING 

When switching from one type of gas to another, the 
minimum flow rate must also be correct. The flame 
should not go out even when passing suddenly from 
maximum to minimum flame. To regulate the flame, 
follow the instructions below:  
Light the burner  
Set the gas valve to minimum 
On gas valves provided with adjustment screw in the 
centre of the shaft (fig.21) 
Using a screwdriver with max. diameter 3mm, turn the 
screw inside the tap until the correct setting is obtained. 
On gas valves provided with adjustment screw on the valve body (fig.22):  

Turn the screw “A” to the correct setting with a screwdriver.

 

LUBRICATION OF THE GAS TAPS  

This can only be performed by an authorised person. It may be required if the gas taps become stiff and 
difficult to turn. 

LEAK TESTING 

1.

 

Make sure gas control knobs are 

Off

 and turn the cylinder valve 

On

2.

 

Check for leaking joints by brushing with solution of half-liquid detergent and half water.  If a leak is present, 

bubbles will appear (or you may hear a hissing sound).  Retightening connections can generally repair a leaking 

joint.  You must also check the gas hose and connection at the gas cylinder.  If a leak cannot be resolved, do not 

proceed. 

 

DO NOT USE NAKED FLAME FOR LOCATING GAS LEAKS. 

IF A LEAK PERSISTS CALL AN AUTHORISED GAS FITTER. 

NOTE: If an appliance cannot be adjusted to perform correctly, contact your nearest service department. 

 

Содержание OCG60X

Страница 1: ...INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS Gas Cooktops OCG60X OCG64X ...

Страница 2: ......

Страница 3: ...o avoid misuse and hazards It is important that you retain these instructions and your proof of purchase along with any other important documents about this product for future reference Due to continual product development Omega reserves the right to alter specifications or appearances without notice CONTENTS SECTION PAGE NO Important Safety Instructions 3 Appliance Details 4 Gas Connections 5 6 E...

Страница 4: ...llation it must be replaced by the manufacturer it s service agent or similarly qualified persons in order to prevent a hazard 7 The electrical and gas connections must be accessible after installation 8 Electrical connection must be made as per local wiring rules and regulations 9 Ensure that the kitchen is well ventilated or mechanical ventilation is in use while cooking on the gas cooktop 10 DO...

Страница 5: ... e g 1 8 for Ø1 80mm injector Semi rapid Burner Semi rapid Burner Wok Burner Auxiliary Burner Table of recommended pot sizes for each burner type Control Knob functions are displayed around each knob as shown below Relevant Sizes LENGTH mm WIDTH mm HEIGHT mm Hob size 580 500 90mm Cut out size 563 483 BURNER TYPE NG DIAMETER OF POT mm ULPG DIAMETER OF POT mm Auxiliary Burner Ø80 TO Ø195 Ø80 TO Ø195...

Страница 6: ... and one gasket fitted between the inlet and elbow The hob must be installed in a room with adequate ventilation see installation section N G Fit the supplied NG regulator to the elbow fitting using two spanners note orientation of the NG regulator gas flow Connect the other side of the NG regulator to the gas inlet pipe with the correct BSPT thread connector using two spanners UNIVERSAL L P G Con...

Страница 7: ...f a test point REGULATING THE BURNER MINIMUM SETTING When switching from one type of gas to another the minimum flow rate must also be correct The flame should not go out even when passing suddenly from maximum to minimum flame To regulate the flame follow the instructions below Light the burner Set the gas valve to minimum On gas valves provided with adjustment screw in the centre of the shaft fi...

Страница 8: ...or coloured red After having installed the appliance the power switch or power plug must always be in an accessible position Electrical connection diagram N B For connections to the mains power supply never use adapters reductions or multiple power points as these may overheat and catch fire In the event that installation should require modifications to the mains supply wiring system or if the pow...

Страница 9: ...fan underneath the hob is forbidden PREPARING PLACING THE HOB FOR INSTALLATION Every cooker top is provided with a set of tabs for fitting to the unit with thickness from 3 to 4 cm and a seal with adhesive on one side Remove burners and grids Turn the cooker top over and rest the top face on a cloth Apply the self adhesive seal G as illustrated in fig 14 Slot the cooker top into the unit and posit...

Страница 10: ...erature This will speed up the cooking time and is more efficient In the event of a power outage your gas cooktop can still be used Press turn the desired knob to the High position and light with a match Depress the knob after approx 3 seconds and continue to operate the burner Large utensils exceeding the recommended size can cause excessive heat to reflect back onto the appliance potentially dam...

Страница 11: ...t pipes should be checked periodically for leakages see section on leak testing a minimum of every 12 months Lubrication of gas valves This can only be performed by an authorised person It may be required if the gas tap become stiff and difficult to turn Fault Possible cause corrective action No spark No ignition of gas Power outage appliance power turned off at isolation switch fuse blown tripped...

Страница 12: ...2018 10 15 ...

Отзывы: