background image

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our 

customers the latest in technology and engineering.
OMEGA is a trademark of OMEGA ENGINEERING, INC.
© Copyright 2017 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, 

reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior 

written consent of OMEGA ENGINEERING, INC.

FOR 

WARRANTY

 RETURNS, please have the  

following information available BEFORE contacting 

OMEGA:
1.   Purchase Order number under which the product 

was PURCHASED,

2.   Model and serial number of the product under 

warranty, and

3.  Repair instructions and/or specific problems  

  relative to the product.

FOR 

NON-WARRANTY

 REPAIRS, consult 

OMEGA for current repair charges. Have 

the following information available BEFORE 

contacting OMEGA:
1.  Purchase Order number to cover the COST  

  of the repair,
2.  Model and serial number of the product, and
3.  Repair instructions and/or specific problems  

  relative to the product.

RETURN REQUESTS/INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE 

RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) 

NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING 

DELAYS). The assigned AR number should then be marked on the outside of the return package and on any 

correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent 

breakage in transit.

WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a 

period of 

13 months

 from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace 

period to the normal 

one (1) year product warranty

 to cover handling and shipping time. This ensures 

that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service 

Department will issue an Authorized Return (AR) number immediately upon phone or written request. 

Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no 

charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, 

including but not limited to mishandling, improper interfacing, operation outside of design limits,  

improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of  

having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; 

or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating 

conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not  

limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However,  

OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for 

any damages that result from the use of its products in accordance with information provided 

by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the 

company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR  

REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF 

TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY 

AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF  

LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of  

OMEGA with respect to this order, whether based on contract, warranty, negligence,  

indemnification, strict liability or otherwise, shall not exceed the purchase price of the  

component upon which liability is based. In no event shall OMEGA be liable for 

 

consequential, incidental or special damages.

CONDITIONS:  Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic 

Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical 

applications or used on humans. Should any Product(s) be used in or with any nuclear installation or 

activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility 

as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify 

OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the 

Product(s) in such a manner.

Содержание NB2TX93A-J2

Страница 1: ...e mail info omega com For latest product manuals www omegamanual info TX93A J K T E 4 20 mA Ultra Miniature Temperature Transmitters TM Shop online at omega com User sGuide...

Страница 2: ...pecifications without notice omega com info omega com Servicing North America U S A Omega Engineering Inc Headquarters Toll Free 1 800 826 6342 USA Canada only Customer Service 1 800 622 2378 USA Cana...

Страница 3: ...1 1 3 General Description 1 1 4 Features 3 1 5 Models Available 4 Section 2 Installation 2 1 Mounting 5 2 2 Wiring 6 Section 3 Calibration Instructions 3 1 Equipment Required 7 3 2 Set up of Equipmen...

Страница 4: ...gure 2 1 Assembly inside an NB2 Protection Head 5 Figure 2 2 Wiring Diagram for Thermocouple Transmitter 6 Figure 3 1 Transmitter Calibration Set Up 9 Figure 3 2 Transmitter Calibration Set Up Alterna...

Страница 5: ...rd Do not expose the transmitter to rain or condensing moisture Do not operate the transmitter in flammable or explosive atmosphere As with any electronic instrument you may encounter high voltage exp...

Страница 6: ...designed to connect with only two copper wire leads that will supply the voltage to operate the transmitter from a power supply and also carry the output current The output current is used for record...

Страница 7: ...and millivolt for all the thermocouple types is somewhat non linear This leads to maximum error at approximately the midpoint of the range as shown in Figure 1 2 Figure 1 2 Straight Line Approximation...

Страница 8: ...o 300 F 18 to 149 C J3 K3 T3 E3 0 to 500 F 18 to 260 C J4 K4 T4 E4 0 to 750 F 18 to 399 C J5 K5 T5 E5 0 to 1000 F 18 to 538 C J6 K6 E6 Table 1 2 Model Numbers Model Number Description TX93A Thermocoup...

Страница 9: ...ounting The transmitter may be 1 surface mounted 2 mounted inside a protection head shown in Figure 2 1 Figure 2 1 Assembly of the Transmitter inside an NB2 Protection Head SECTION A A POWER LINES T C...

Страница 10: ...series with the load to the PS and PS power terminals Note that the load usually a monitoring instrument may be connected to either the or power lead 2 Connect the thermocouple to the IN and IN input...

Страница 11: ...Number TRP Thermocouple Type J K T E 3 2 Set Up of Equipment To prepare the ice bath Refer to Figure 3 1 a Fill a glass beaker with crushed ice made from distilled water b Fill the beaker with enough...

Страница 12: ...model number For example for Model TX93A J2 the Z input is 0 886 mV and the S input is 4 907 mV If a Thermocouple Calibrator Simulator is used such as the Model CL511 Precision Calibrator select the...

Страница 13: ...9 3 3 Calibration Procedures continued Figure 3 1 Transmitter Calibration Set Up Figure 3 2 Transmitter Calibration Set Up Alternate...

Страница 14: ...2 255 40 120 F E1 2 255 2 977 0 200 F T2 0 675 3 968 E2 1 026 5 871 0 300 F T3 0 675 6 648 E3 1 026 9 710 0 500 F T4 0 675 12 574 E4 1 026 17 945 0 750 F T5 0 675 20 803 E5 1 026 28 857 0 1000 F E6 1...

Страница 15: ...rmula Loop Resistance maximum Vsupply 8 V 0 020A For example a 24V power supply would give a maximum loop resistance of 16 V 0 020A 800 ohms c Make sure the power supply is rated for at least 28 mA ti...

Страница 16: ...uency Response 3dB 3Hz Thermal Zero Shift 0 01 F of span span 10 mV 0 02 F of span 4 10 mV span Thermal Span Shift 0 01 F of span Output Current Output Span 4 20 mA dc Current Output Limits 3 to 28 mA...

Страница 17: ..._ ________________________________________ ________________________________________ ________________________________________ ________________________________________ __________________________________...

Страница 18: ..._ ________________________________________ ________________________________________ ________________________________________ ________________________________________ __________________________________...

Страница 19: ...A if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to m...

Страница 20: ...s M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U...

Отзывы: