Omega MAX-EDP Скачать руководство пользователя страница 3

Page - 3

Table of Contents

Introduction ............................................................................. 4-7

Status Light, Valet Switch & Transmitter

System Versatility - 

An Important Note ........................................

7

Using the MAX-EDP System ................................................. 8

Arming Using the Transmitter ................................................ 7-8

Arming Bypass, Sensor Bypass

Automatic “Last Door Arming” of the System ...................... 9-10

While the System is Armed, and should it Trigger ................ 10-11

Prewarning Detection Circuit

Disarming the System Using the Transmitter ......................... 11-12

Safety Disarm Feature; Activation Alert; Automatic Rearming

Disarming By Emergency Override ....................................... 12-13

Remote Panic Feature ............................................................. 13-14

Remote Engine Starting .......................................................... 14-17

Safety Features, Stick Shift Remote Starting; Pit-Stop; Turbo Timer

Other Transmitter Operations ................................................. 18

2nd Channel, 3rd Channel, Silent Arming & Disarming

Sensor Bypass

Using the Valet Switch ........................................................... 19-20

Alarm Valet Mode & Starting Valet Mode

SecureCode .............................................................................. 21

The Status Light ...................................................................... 22-23

Anti-Carjacking Protection ..................................................... 24-25

Transmitter Protection ............................................................. 25

How to Program Transmitters ................................................. 25-26

How to Program Features ....................................................... 27-28

User Programmable Features .................................................. 29-37

Installer Programmable Features ............................................ 38-42

Complete Programmable Features Matrix .............................. 43

Limited Lifetime Warranty .............................................. Back Cover

for the voltage sensing type of starter output operation.  There are four
different base starter output settings.  While the default-set minimum is
sufficient for most vehicles; the Extended Starter Cranking Time can be
used for difficult-to-start engines.  This feature should only be pro-
grammed by the installer
.
Note: “Base timing” is the maximum time period that the MAX-EDP will
engage the starter, but only if it does not detect the engine has started
running.

Feature #10   Gasoline Or Diesel Engine

Factory Default Setting

Gasoline      (press “arm/lock” button to program)

Option:

           Diesel      (press “disarm/unlock” button to program)

This feature changes the system's timing of the ignition and starter output
sequence for remotely starting vehicles with a diesel engine.  This feature
should only be programmed by the installer
.

Feature #8   Programmable Remote Start Relay

Factory Default Setting

Ignition Output
(press “arm/lock” button to program)

Options:
Accessory Output

(press “disarm/unlock” button to program)

Starter Output

(press 

OPTION

 button  to program)

The MAX-EDP features 4 dedicated remote start output relays, one of which
is programmable (this is the unit’s large blue output wire).  Operation
choices are ignition, accessory or starter power output.    This feature
should only be programmed by the installer
.

Feature #9   Arm, Disarm or Additional Channels

Factory Default Setting

Arm / Disarm
(press “arm/lock” button to program)

Options:
Arm / Channel 5

(press “disarm/unlock” button to program)

Channel 4 / Disarm

(press 

OPTION

 button  to program)

Channel 4 / Channel 5

(press red 

panic

 button  to program)

The MAX-EDP has outputs designed for arming and/or disarming a factory-
equipped security system.  These wires may be used instead to provide
further system outputs, which are remotely operated by the transmitter.
These outputs are in addition to the 2nd channel and 3rd channel outputs,
the operation of these outputs is explained on page 18.

As shown in the programming assignment, the arm, disarm, channel 4

and channel 5 are programmable as various combinations.  For example,
if the disarm output is needed, but not the arm output, then channel 4 may
be made available for use.

Page - 42

Содержание MAX-EDP

Страница 1: ...God This warranty limits the Company s liability to the repair or replacement of theproduct TheCompanyshallnotberesponsibleforremovaland orreinstallation charges damage to or theft of the vehicle or...

Страница 2: ...O 4 Starter Interrupt Functions Alarm only L Off U Automatic O Alarm AntiGrind p 5 Ignition Activated Override OFF U ON L 6 Doors Lock With Ignition On ON L OFF U 7 Doors Unlock With Ignition Off ON...

Страница 3: ...engine has started running Feature 10 Gasoline Or Diesel Engine Factory Default Setting Gasoline press arm lock button to program Option Diesel press disarm unlock button to program This feature chang...

Страница 4: ...hich keeps the engine running after removing the ignition key After exiting the user must then arm the system locking the vehicle doors by pressing the arm lock button Only after this is done will the...

Страница 5: ...nsmission equipped vehicles via a setup procedure which must be followed upon exiting the vehicle When this feature is turned on the operator must set the parking brake and then Feature 4 Turbo Timer...

Страница 6: ...s also more suitable in some newer vehicles Some newer vehicles require a double pulse output to remotely unlock the doors and or to disarm a factory equipped security system which is what the Double...

Страница 7: ...e Installer Programmable Features are accessed as the second level of features programming which is pressing the Valet Switch 10 times instead of 5 times when entering Programming Mode page 27 Caution...

Страница 8: ...n the red color The system s reaction The parking and interior lights will flash once the siren will chirp once and the Status Light will begin to flash red confirming that the system is armed In addi...

Страница 9: ...Last Door Arming process stops and will reset to start over when the point of entry is again closed All protected entries must be closed to initiate the Last Door Arming sequence To temporarily preve...

Страница 10: ...ded Last Door Arming offers a high level of security since you do not have to remember to arm the security system every time you leave the vehicle and using it may entitle you to an insurance discount...

Страница 11: ...cations and Zone Violation code will remain this way until the ignition key is turned on Page 34 Feature 11 Alarm Duration Factory Default Setting 30 Seconds press arm lock button to program Options 6...

Страница 12: ...hin 5 seconds press and release the Valet Switch one time The system will disarm Step 2 Using the ignition key turn the vehicle s ignition switch on The number of Valet Switch presses which are requir...

Страница 13: ...Factory Default Setting Off press disarm unlock button to program Option On press arm lock button to program This feature allows an activated system to be overridden and disarmed by simply turning th...

Страница 14: ...it on demand before it times out again press and releasetogetherthetransmitter s arm lock and disarm unlock buttons The system will stop the engine and extinguish the parking lights This feature turn...

Страница 15: ...mega MAX EDP is installed into a manual transmission vehicle Installer Program mable Feature 5 must be turned on Then whenever remote starting will be desired at a later time the following procedure m...

Страница 16: ...he engine running normally from the ignition switch have the gear selector in park and your foot off of the brake pedal Press the Valet Switch twice the parking lights will flash once and the siren ch...

Страница 17: ...he same number of times as the desired feature s number The siren will chirp and the Status Indicator Light will flash as many times as the Valet Switch was pressed to indicate the feature number whic...

Страница 18: ...ressing the disarm unlock and red panic buttons will activate the 5th channel Or if desired the transmitter panic button can be programmed by User Programming Feature 21 to operate any of these channe...

Страница 19: ...r optional controllers which are to operate the system at hand Turn the ignition on If the Unauthorized Transmitter Alert feature is on programming a transmitter or optional controller to the system w...

Страница 20: ...er AlertTM UTA is a protection feature which may be turned on by the user see the next section How to Program Transmitters Whenthisprotectionfeatureisutilized wheneveratransmitter or optional 2 way co...

Страница 21: ...jackingprotection features whose operation may be selectively activated by the ignition by an open door or by the transmitter All three are programmable and must be turned on to operate Once activated...

Страница 22: ...ogrammed 6 2 Red Flashes pause 2 transmitters are programmed 9 2 Red Flashes Pause System was triggered by open hood or trunk 10 3 Red Flashes Pause System was triggered by an open door 21 Slowly Alte...

Отзывы: