manualshive.com logo in svg
background image

Display:

5 x 0.5” (12.7mm) numeric digits plus 5 Alpha-numeric LCD

Batteries:

2 “AA” 1.5 V       (DC) alkaline included

 (Note:  Batteries are NOT rechargeable.)

Battery Life:

30 hours continuous typical with batteries provided

External Input:

Absolute max:

-0.3 V to 5 V       (DC)

Minimum:

low below 1.2 V and high above 2 V (TTL compatible)

Edge:

Triggers on Positive edge

Power Out:

3.0 V nominal, approx. 2.8 V @ 20 mA max

Pulse Output:

0 V to 3.3 V       (DC) pulse

Same shape as External Input signal or high when internal
optics sees a reflection

Dimensions:

6.92” (17.58 cm) H x 2.4” (6.10 cm) W x 1.6” (4.06 cm) D

Weight:

Approx. 7 oz. (210 g)

This product is designed to be safe for indoor use under the following
conditions (per IEC61010-1).

Installation Category II

per IEC 664

Pollution Degree Level II

per IEC 664

Temperature:

40 °F to 105 °F (5 °C to 40 °C)

Humidity:

Maximum relative humidity of 80% for temperatures up
to 88 °F (31 °C) decreasing linearly to 50% relative
humidity at 100 °F (40 °C).  Humidity non-condensing.

Specifications subject to change without notice.

6

17

TOTALizer Setup (continued):

NONE

1

2

 or 

3

OR

Repeat until
desired decimal
places displayed

Unit will remember these settings (including lock on/off) even if turned off
and back on.

DONE

,

then Units selected

DONE

,

USE CONTACT TIP 

or

[wheel selected],
then Units selected

Units = 

COUNT

:

Rotational/Linear Units:

9.

Enter selection
of number of
decimal places

10. Select decimal

places

11. Save and

advance

12. Exit Setup –

Ready to
measure

Содержание HHT13

Страница 1: ...sed on humans or misused in any way OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnify OMEGA and hold OMEGA harmless from...

Страница 2: ...tated This instrument is not user serviceable For technical assistance contact the sales organization from which you purchased the product In order to comply with EU Directive 2002 96 EC on Waste Elec...

Страница 3: ...E Operation 14 8 0 TOTALizer Mode 15 8 1 TOTALizer Setup 15 8 2 TOTALizer Operation 18 9 0 TIMER Mode 19 9 1 TIMER Setup 19 9 2 TIMER Operation 20 10 0 MAKINGMEASUREMENTS 21 10 1 Non Contact Measureme...

Страница 4: ...arrow LCD display Menu Select and Lock on button Battery compartment AVOID EXPOSURE LASER RADIATION IS EMITTED FROM THIS APERTURE Output socket Input socket Belt clip Tripod mounting bushing undersid...

Страница 5: ...easurements Lock mode Hand held 21 10 0 MAKING MEASUREMENTS 10 1 Non Contact Measurements 10 2 Direct Contact Measurements Laser External Sensor HHT20 ROS shown OR Light WARNING Making measurements in...

Страница 6: ...resolution limit Operating Range up to 25 feet 7 62 m or up to 70 degrees off perpendicular to reflective tape target Contact Specifications using optional Remote Contact Assembly Range Contact Tips...

Страница 7: ...00 to 999 990 IPH Feet per Second 10 cm 0 003 to 109 36 FT S 12 in 0 009 to 200 00 FT S Feet per Minute 10 cm 0 164 to 6 561 7 FT M 12 in 0 500 to 12 000 FT M Feet per Hour 10 cm 9 843 to 393 700 FT...

Страница 8: ...per Hour 10 cm 3 000 to 120 000 M H 12 in 9 144 to 219 460 M H TOTALIZER Counts 0 to 999 999 Scale Totals in Inches Feet Yards Centimeters or Meters Input Internal or External optics or linear contact...

Страница 9: ...to be safe for indoor use under the following conditions per IEC61010 1 Installation Category II per IEC 664 Pollution Degree Level II per IEC 664 Temperature 40 F to 105 F 5 C to 40 C Humidity Maximu...

Страница 10: ...For Small Shafts Select and install contact option 1 Contact Tip Convex tip shown Use Concave tip for small shafts Align flats 16 6 Enter selection of Units 7 Select Units 8 Save and advance Rotationa...

Страница 11: ...with optional 12 inch wheel In S S S S S 15 1 Turn Power ON 2 Enter Setup Mode 3 Enter selection of Mode 4 Select TOTAL Mode 5 Save and advance OR Repeat until TOTAL displayed Last Mode selected is di...

Страница 12: ...RPM or RPH Last Units selected are displayed Locked On Press and Hold 14 Unit will remember these settings including lock on off even if turned off and back on DONE USE CONTACT TIP or wheel selected...

Страница 13: ...o measure 13 Rotational CRPS CRPM or CRPH Linear IPS IPM IPH FT S FT M FT H YPS YPM YPH MPH CM S CM M CM H M SEC M MIN M H NONE 1 2 or 3 OR Repeat until desired decimal places displayed OR Repeat unti...

Страница 14: ...R 12 1 Turn Power ON 2 Enter Setup Mode 3 Enter selection of Mode 4 Select RATE Mode 5 Save and advance OR Toggles between RATE and TOTAL Select RATE Last Mode selected is displayed 1a To toggle Lock...

Отзывы: