manualshive.com logo in svg
background image

OMEGAnet

SM

 On-Line Service

http://www.omega.com

Internet e-mail

[email protected]

For immediate technical or application assistance:

USA and Canada:

Mexico and Latin America:

Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA

SM

Tel: (95) 800-TC-OMEGA

SM

Customer Service: 1-800-622-2378 / 1-800-622-BEST

SM

FAX: (95) 203-359-7807

Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN

SM

En Español: (203) 359-7803

TELEX: 996404  EASYLINK: 62968934  CABLE: OMEGA e-mail: [email protected]

Servicing North America:

USA:

 ISO 9001 Certified

Canada:

One Omega Drive, Box 4047

976 Bergar

Stamford, CT 06907-0047 Laval (Quebec) H7L5A1

Tel: (203) 359-1660

Tel: (514) 856-6928

FAX: (203)359-7700

FAX: (514) 856-6886

e-mail: [email protected] e-mail: [email protected]

Servicing Europe:

Benelux:

Postbus 8034, 1180 LA Amstelveen,

The Netherlands

Tel: (31) 20 6418405 FAX: (31) 20 6434643

Toll Free in Benelux: 06 0993344

e-mail: [email protected]

Czech Republic:

ul. Rude armady 1868, 733 01 Karvina-

Hranice, Czech Repubic

Tel: 420 (69) 6311627 FAX: 420 (69)

6311114

e-mail: [email protected]

France:

9, rue Denis Papin, 78190 Trappes

Tel: (33) 130-621-400 FAX: (33)130-699-120

Toll Free in France: 0800-4-06342

e-mail: [email protected]

Germany/Austria:

Daimlerstrasse 26, D-75392

Deckenpfronn, Germany

Tel: 49 (07056) 3017 FAX: 49 (07056) 8540

Toll Free in Germany: 0800 82 66342

e-mail: [email protected]

United Kingdom:

 

ISO 9002 Certified

One Omega Drive

Riverbend Technology Centre Northbank, Irlam,

Manchester, M44 5EX, England

Tel: 44 (161) 777-6611 FAX: 44 (161) 777-6622

Toll Free in England: 0800-488-488

e-mail: [email protected]

omega.com

TM

Содержание HHM64

Страница 1: ...OMEGA HHM64 Digital Multimeter ...

Страница 2: ... info omega com e mail info omega com Servicing Europe Benelux Postbus 8034 1180 LA Amstelveen The Netherlands Tel 31 20 6418405 FAX 31 20 6434643 Toll Free in Benelux 06 0993344 e mail nl omega com Czech Republic ul Rude armady 1868 733 01 Karvina Hranice Czech Repubic Tel 420 69 6311627 FAX 420 69 6311114 e mail czech omega com France 9 rue Denis Papin 78190 Trappes Tel 33 130 621 400 FAX 33 130...

Страница 3: ...ower mains The unit is intended for use with low energy circuits to 600V AC DC or high energy circuit to 250 VAC or DC 3 Use caution when working above 60V dc or 30V ac rms Such voltages pose a shock hazard 4 When using the probes keep your fingers behind the finger guards on the probes 5 Measuring voltage which exceeds the limits of the meter may cause damage and expose the operator to a shock ha...

Страница 4: ... voltage drops below the operating level Auto power down After 10 mins Back Light after 30 secs approx Measurement rate 2 times per second nominal Operating environment 0 C to 50 C at 70 relative humidity Storage environment 20 C to 60 C at 80 relative humidity Safety According to EN61010 1 protection class II overvoltage category CAT II 600V pollution degree 2 Power 4 pcs 1 5V AAA size Battery li...

Страница 5: ...0 25 rdg 1digit Input impedance 320mV 1000MW 3 2V 11MW 32V to 600V 10MW Maximum input 600VDC or AC rms AC Voltage 50Hz 400Hz Ranges 3 2V 32V 320V 600V Accuracy 0 75 rdg 4digits Input impedance 320mV 1000MW 3 2V 11MW 32V to 600V 10MW Maximum input 600VDC or AC rms 3 ...

Страница 6: ... 1KW 32MW 10KW Accuracy 320W 0 3 rdg 3dgts 3 2KW to 320KW 0 3 rdg 3dgts 3 2MW 1 2 rdg 1dgt 32MW 3 0 rdg 1dgt Test current 320W 0 7mA 3 2KW 0 13mA 32KW 13µA 320KW 1 3µA 3 2MW 32MW 0 13µA Input protection 500VDC or AC rms Diode Test Test range 0 2 0V Resolution 1mV Accuracy 10 rdg 3dgts Test current 0 8mA 0 6mA Input protection 500VDC or AC rms ...

Страница 7: ... the Safety Information Section Always examine the instrument for damage contamination excessive dirt grease etc and defects Examine the test leads for cracked or frayed insulation If any abnormal conditions exist do not attempt to make any measurements Autoranging The meter defaults to autorange when you turn it on In autorange the meter selects the range automatically ...

Страница 8: ...de Switch W Press this switch to toggle between DC and AC in the voltage measurements Press this switch to toggle between the W continuity diode modes If the function switch is set to W position Back Light and Data Hold Switch 2sec H Press this button briefly to activate DATA HOLD mode The H annunciator is displayed Press this button for two seconds to turn the Back Light on As this also activates...

Страница 9: ...COM jack 2 Set the Function switch to the V V position and press the mode switch to select DC or AC 3 Touch the probes to the test points the range will change automatically to the level that will display the input voltage with best resolution 4 The value indicated in the display window is the measured value of voltage with proper decimal point and annunciator indication 5 For dc a sign is display...

Страница 10: ...onnect the test leads to measurement points and read the value from the display WARNING The accuracy of the functions might be slightly affected when exposed to a radiated electromagnetic field environment eg radio telephone or similar Diodes Testing 1 Set the Function switch to W position 2 Turn off power to the circuit under test External voltage across the compo nents causes invalid readings 3 ...

Страница 11: ...pen OL is displayed in both directions Continuity Measurements 1 Set the Function switch to W position 2 Turn off power to the circuit under test External voltage across the compo nents causes invalid readings 3 To toggle between the W continity diode modes press Mode Switch 4 Connect the test leads to the two points at which continuity is to be tested The buzzer will sound if the resistance is le...

Страница 12: ...5V AAA size batteries The appears on the LCD display when replacement is needed To replace the batteries remove the screw from the back of the meter and lift off the battery cover case Remove the batteries from battery contacts Cleaning Periodically wipe the case with a damp cloth and detergent do not use abrasives or solvents MAINTENANCE ...

Страница 13: ...use of its various products Nevertheless OMEGA only warrants that the parts manufactured by it will be as specified and free of defects OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER EX PRESSED OR IMPLIED EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WAR RANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED LIMITATION OF LIAB...

Страница 14: ...pondence The purchaser is responsible for shipping charges freight insurance and proper packaging to prevent breakage in transit FOR WARRANTY RETURNS please have the following information available BEFORE contacting OMEGA 1 P O number under which the product was PURCHASED 2 Model and serial number of the product under warranty and 3 Repair instructions and or specific problems relative to the prod...

Страница 15: ...ctors Panels Assemblies þ Wire Thermocouple RTD Thermistor þ Calibrators Ice Point References þ Recorders Controllers Process Monitors þ Infrared Pyrometers ENVIRONMENTAL MONITORING AND CONTROL þ Metering Control Instrumentation þ Refractometers þ Pumps Tubing þ Air Soil Water Monitors þ Industrial Water Wastewater Treatment þ pH Conductivity Dissolved Oxygen Instruments pH CONDUCTIVITY þ pH Elect...

Отзывы: