background image

User’s manual    for VC99 3 6/7 DMM   

1.SUMMARY 

   

This digital multimeter is a steady performance, battery-driven 3 6/7 digital multimeter. 

It  uses  the  LCD  with  23mm-high  figure  to  make  the  reading  clear  and  make  operation  more 

convenient. 

The  digital  multimeter  has  the  function  of  measuring  DCV,  ACV,  DCA,  ACA,  resistance, 

capacitance,  frequency,  temperature,  duty  cycle,  transistor  and  diode,  continuity  performance 

test  .The  meter  can  provide  functions  including  analog  bar  and  unit  symbol  display,  data 

holding,  relative  value  measuring,  maximal/minimal  value  measuring,  auto/manual  range 

switching  (RANGE),  auto  power  off  and  warning  functions  .it  adopts  double  integral  A/D 

converter as its core. It is an ideal tool for labs, factories and radio-technology. 

2.SAFTY NOTES

 

              The instrument is designed according to IEC1010 standard (safety standard issued by 

International Electro technical Committee). Please read the following before operation. 

1-1.Check the connection and insulation of test leads to avoid electric shock. 

1-2.Do not input a limited voltage higher than DC 1000V or AC 750V when measuring ranges. 

1-3.When measuring voltage higher than DC 60V, AC 40V, please be careful. 

1-4. Select correct function and range to avoid fault operation. 

1-5.Please move the test leads away from test points when switching the function. 

1-6.Please don’t input voltage value when measuring current. 

1-7.Please don’t modify the circuit. 

1-8.Introduction for safety symbol: 

  “

”  exists  high  voltage;  “

”  GND  “

”  dual  insulation  “

”  must  refer  to 

manual “

” Low battery. 

3. SPECIFICATION

 

1. General features 

1-1. Displaying: LCD; 

1-2.Max  display:  6000(3  6/7)  digits  automatic  polarity,  unit  symbol  and  61  section  analog 

display; 

1-3. Measurement method: double integral A/D conversion; 

1-4. Sampling rate: approx.3 times/sec. 

1-5. Over-range display: “OL” displayed in the highest digit.   

1-6. Low battery display

” 

1-7. Working environment: (0

40)

, relative humidity: <80%; 

1-8.Store environment: (-10

40)

, relative humidity: <80%; 

1-9.Power supply

2pcs 1.5V battery

“AAA”7# battery

 

1-10. Dimension: 185×93×35mm (length*width*height); 

1-11. Weight: approx..290g

(including    battery)

 

1-12.Accessories:  test  leads,  user  manual,  temperature  probe,  holster,  gift  box,  and  2*1.5V 

battery. 

2. TECHNICAL FEATURES 

2-1. Accuracy: ± (a% × reading data + digits), environment temperature at (23±5) 

, relative 

humidity<75%, One year guarantee since production date. 

2-2.DC Voltage

DCV

 

Range 

Accuracy 

Resolution 

600mV 

±(0.5%+3) 

0.1mV 

6V 

1mV 

60V 

10mV 

600V 

100mV 

1000V 

±(0.8%+3) 

1V 

Input impedance: approx. 10MΩ 

Overload protection

1000V DC or 750V AC. 

2-3.AC Voltage

ACV

 

Range 

Accuracy 

Resolution 

6V 

±(0.8%+5) 

1mV 

60V 

10mV 

600V 

100mV 

750V 

±(1.0%+5) 

1V 

Input impedance: approx. 10MΩ 

Overload protection

1000V DC or 750V AC. 

Frequency response:

40

200

Hz under 750V ,other range:(40

400

Hz. 

Sine wave RMS(Average value response). 

2-4.DC Current

DCA

 

Range 

Accuracy 

Resolution 

600uA 

±(1.0%+3) 

0.1μA 

6000uA 

1μA 

60mA 

10μA 

600mA 

100μA 

6A 

±(2.0%+5) 

1mA 

20A 

10mA 

MAX measurement voltage drop:

full range mA :300mV

A:100mV

 

Max input current: 20A (within 15 seconds) 

Over load protection: 500mA/ 250V and 13A/250V 

fast molten fuse. 

2-5.AC Current

ACA

 

Range   

Accuracy 

Resolution 

600uA 

±(1.2%+5) 

0.1μA 

6000uA 

1μA 

40mA 

10μA 

600mA 

100μA 

6A 

±(2.0%+15) 

1mA 

20A 

10mA 

MAX measurement voltage drop:

full range mA :400mV

A:200mV

 

Max input current: 20A (within 15 seconds) 

Over load protection: 500mA/ 250V and 13A/250V 

fast molten fuse. 

Frequency response

20A range:40

100Hz,other range:40

400Hz

 

2-6.Resistance

Ω

 

Range 

Accuracy 

Resolution 

600Ω 

±(0.8%+5) 

0.1Ω 

6kΩ 

±(0.8%+3) 

1Ω 

60kΩ 

10Ω 

600kΩ 

100Ω 

6MΩ 

1kΩ 

60MΩ 

±(1.2%+5) 

10kΩ 

Open circuit voltage:

600mV 

Over load protection: 250V DC or AC peak value; 

NOTE:

  At  range  600  Ω,  short-circuit  the  test  leads  to  measure  the  wire  resistance  and  then 

subtracts it from the real measurement. Or press “”REL” to clear the wire resistance and read 

the value directly. 

2-7.CAPACITANCE

C

 

RANGE 

ACCURACY 

RESOLUTION 

40nF 

±(2.5%+6) 

10pF 

400nF 

±(2.5%+5) 

100pF 

4μF 

1nF 

40μF 

10nF 

400μF 

±(5.0%+8) 

100nF 

2000μF 

1uF 

Overload protection :250V DC or AC peak value. 

Summary of Contents for VC99

Page 1: ...relative humidity 80 1 8 Store environment 10 40 relative humidity 80 1 9 Power supply 2pcs 1 5V battery AAA 7 battery 1 10 Dimension 185 93 35mm length width height 1 11 Weight approx 290g including battery 1 12 Accessories test leads user manual temperature probe holster gift box and 2 1 5V battery 2 TECHNICAL FEATURES 2 1 Accuracy a reading data digits environment temperature at 23 5 relative h...

Page 2: ... terminal 3 Auto range is the original states it will display AUTO symbol press RANGE key change to manual range mode 600mV 6V 60V 600V 1000V range is selective 4 Connect the leads crossly to the electric circuit under test LCD displays polarity and voltage under test connected by the red test lead Note 1 Firstly users should select the knob to the highest range if users had no idea about the rang...

Page 3: ...econds 4 8 Frequency measurement 1 Insert the black lest lead to COM terminal and the red one to V Ω Hz terminal 2 select the knob to Hz range insert the test leads or shielded cable to the signal source or the load which is tested 3 Press Hz DUTY key to switch frequency duty cycle it will display the frequency or duty cycle of the signal source which is tested Note 1 There is only the auto range ...

Page 4: ...ol 8 If do not operate for a long time should take out the battery to avoid leakage 9 When symbol displays should replace the battery following the steps 9 1 see picture 2 move holster at first 9 2 Unlock the button and remove the battery case 9 3 Take out the old battery and replace the new one It s better to use alkaline battery for longer life 9 4 fit on battery case and bolt 9 5 see the pictur...