background image

GENERAL INFORMATION

4.10

2.20

2.10 (FPR300)

2.25 (FPR310)*

18 Ft. Cable

(standard)

Female NPT

thread size varies 

with model #.

See chart 

1.20

*NOTE:

FPR310 cover 

screws are not 

recessed

1.625

Dimensions

Specifications*

FPR300

FPR310

Connection Ports

3/8”, 1/2”, 3/4”, 1” —Female NPT thread

3/8”, 1/2”, 3/4”, 1” —Female NPT thread

Sensor Cable

18 ft (6 m) standard—maximum cable run 2000 ft 

(607 m)

18 ft (6 m) standard—maximum cable run 2000 ft 

(607 m)

Materials

Body

Polypropylene

PTFE

Rotor

PVDF—2 magnet

(6 magnet high resolution optional)

PVDF—2 magnet

(6 magnet high resolution optional)

Shaft

Nickel tungsten carbide

(ceramic or silicon carbide optional)

Zirconia ceramic

(silicon carbide optional)

O-Ring

EDPM (FKM or PTFE-coated FKM optional)

PTFE-coated FKM 

(FKM or EDPM optional)

Bearings

Ruby ring and ball

Ruby ring and ball

Cover

Acrylic with clear lens

 

(polypropylene without clear lens optional)

PTFE

Maximum Temperature

160˚ F (70˚ C)

180˚ F (82˚ C)

Maximum Pressure

150 psi (10 bar)

150 psi (10 bar)

Accuracy

±1% of full scale

±1% of full scale

Power

6–36 Vdc, 2 mA min.

6–36 Vdc, 2 mA min.

Outputs

Current sinking pulse, 6–24 Vdc

Current sinking pulse, 6–24 Vdc

* Specifications subject to change. Please consult our website for current data (omega.com)

Model #

NPT Thread Size

-038

3/8”

-050

1/2”

-075

3/4”

-100

1”

Pr

essur

e Dr

op (PSI)

Flow (GPM)

0

5

10

15

20

25

30

35

5

10

15

20

3/8"

1/2"

3/4"

1"

Model #

K-Factor* (pulses/gal)

Gal/Min

Liter/Min

FPR310

FPR300

-038

1394

1417

0.07–5

0.27–18.9

-050

634

658

0.1–10

0.38–37.9

-075

476

468

0.2–20

0.75–75

-100

250

254

0.5–40

1.9–150

*Nominal K-factors (based on averages) for standard 2-magnet FPR310 

and FPR300. High resolution (6-magnet) K-factors are approximately 

tripled.

Flow Range

Pressure Drop Curves

FPR300/310 SERIES INSTRUCTIONS

 

Page 5 

omega.com

Содержание FPR310 Series

Страница 1: ...e mail info omega com For latest product manuals www omegamanual info User sGuide Shop online at omega comSM FPR300 FPR310 FPR300 310 SERIES Low Flow Meter...

Страница 2: ...ering Service 1 800 872 9436 USA Canada only Tel 203 359 1660 Fax 203 359 7700 e mail info omega com For Other Locations Visit omega com worldwide omega com info omega com The information contained in...

Страница 3: ...Page 5 Installation Connections Piping Requirements Page 6 K Factor Page 6 Connections to Control Devices Page 6 Repair Rotor Replacement Page 7 Sensor Replacement Page 7 FPR300 310 Parts List Page 8...

Страница 4: ...pes of controls including a full range of Omega rate displays and controls The Omega DPF 143 and DPF 144 provide flow rate and total flow indication The DPF 144 also includes 4 20 mA output capability...

Страница 5: ...ring and ball Ruby ring and ball Cover Acrylic with clear lens polypropylene without clear lens optional PTFE Maximum Temperature 160 F 70 C 180 F 82 C Maximum Pressure 150 psi 10 bar 150 psi 10 bar A...

Страница 6: ...cal 2 The sensor power supply can provide at least 2 mA 100 mA is typical 3 The sensor input on the PLC can accept a current sinking device 4 The PLC frequency response flow meter output frequency Inp...

Страница 7: ...ing the cover The rotor can be easily dropped into the bottom bearing Starting the shaft into the upper bearing requires a bit of care It is easier if the rotor is spinning which can be done by lightl...

Страница 8: ...Ceramic 6 magnet high res 100453 100453 PVDF Carbide 6 magnet high res 103932 n a PVDF Silicon Carbide 6 magnet high res 103934 103934 5 O Ring EPDM 100264 standard 100264 optional FKM 100219 optiona...

Страница 9: ...nd check for free spinning replace rotor Failed magnetic sensor Replace magnetic sensor Inaccurate metering Not enough straight pipe between meter and severe flow disturbance Move meter away from flow...

Страница 10: ...FPR300 310 SERIES INSTRUCTIONS Page 10 omega com...

Страница 11: ...y OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limite...

Страница 12: ...locity Indicators M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simu...

Отзывы: