background image

GENERAL INFORMATION

These  versatile  impeller  flowmeters  are  available  in  3/8”, 

1/2”,  3/4”,  and  1”  nominal  pipe  sizes  with  female  NPT 

threads.  They employ jewel bearings to allow for very low 

minimum flow rates and superior life.

The 

FPR300, with a body of polypropylene, is an economical 

choice for metering water or low corrosion fluids. The lens 

cover is available in a choice of materials:  acrylic for visual 

flow  indication  of  low-corrosion  fluids;  polypropylene 

when more corrosion resistance is needed. The standard 

rotor assembly is PVDF with tungsten carbide shaft.  The 

O-ring is EPDM.

The 

FPR310

 offers greater chemical resistance with a PTFE 

body  and  cover,  PTFE-coated  FKM  O-ring,  and  standard 

PVDF/ceramic rotor assembly.

The pulse output of these meters is compatible with many 

different types of controls, including a full range of Omega 

rate  displays  and  controls.    The  Omega  DPF-143  and 

DPF-144  provide  flow  rate  and  total  flow  indication.  The 

DPF-144 also includes 4-20 mA output capability. The FMG-

1000-MAW may be used for blind 4-20 mA transmission.

Features

FPR300/310 SERIES INSTRUCTIONS

 

Page 4 

omega.com

FPR300

Thread-in Sensor, Field Replaceable,

6–24 Vdc Pulse

18’ Sensor Cable

Standard Acrylic Top with Clear 

Removable Lens Assembly

(optional polypropylene top  

without clear lens)

Polyproylene Body

Female NPT Ports

Hex Screws

Internal

• 

Jewel Bearings—Ruby Ring and Ball

• 

PVDF/Tungsten Carbide Rotor Assembly 

(PVDF/Ceramic or  

PVDF/Silicon Carbide optional)

•  EPDM O-Ring (FKM or PTFE-coated FKM optional)

Thread-in Sensor, Field Replaceable,

6–24 Vdc Pulse

18’ Sensor Cable

PTFE Body and Top

Female NPT Ports

Screws with Hex Nuts

Internal

• 

Jewel Bearings—Ruby Ring and Ball

• 

PVDF/Ceramic Rotor Assembly 

(PVDF/Silicon Carbide 

optional)

• 

PTFE-coated FKM O-Ring 

(FKM or EPDM optional)

FPR310

Содержание FPR310 Series

Страница 1: ...e mail info omega com For latest product manuals www omegamanual info User sGuide Shop online at omega comSM FPR300 FPR310 FPR300 310 SERIES Low Flow Meter...

Страница 2: ...ering Service 1 800 872 9436 USA Canada only Tel 203 359 1660 Fax 203 359 7700 e mail info omega com For Other Locations Visit omega com worldwide omega com info omega com The information contained in...

Страница 3: ...Page 5 Installation Connections Piping Requirements Page 6 K Factor Page 6 Connections to Control Devices Page 6 Repair Rotor Replacement Page 7 Sensor Replacement Page 7 FPR300 310 Parts List Page 8...

Страница 4: ...pes of controls including a full range of Omega rate displays and controls The Omega DPF 143 and DPF 144 provide flow rate and total flow indication The DPF 144 also includes 4 20 mA output capability...

Страница 5: ...ring and ball Ruby ring and ball Cover Acrylic with clear lens polypropylene without clear lens optional PTFE Maximum Temperature 160 F 70 C 180 F 82 C Maximum Pressure 150 psi 10 bar 150 psi 10 bar A...

Страница 6: ...cal 2 The sensor power supply can provide at least 2 mA 100 mA is typical 3 The sensor input on the PLC can accept a current sinking device 4 The PLC frequency response flow meter output frequency Inp...

Страница 7: ...ing the cover The rotor can be easily dropped into the bottom bearing Starting the shaft into the upper bearing requires a bit of care It is easier if the rotor is spinning which can be done by lightl...

Страница 8: ...Ceramic 6 magnet high res 100453 100453 PVDF Carbide 6 magnet high res 103932 n a PVDF Silicon Carbide 6 magnet high res 103934 103934 5 O Ring EPDM 100264 standard 100264 optional FKM 100219 optiona...

Страница 9: ...nd check for free spinning replace rotor Failed magnetic sensor Replace magnetic sensor Inaccurate metering Not enough straight pipe between meter and severe flow disturbance Move meter away from flow...

Страница 10: ...FPR300 310 SERIES INSTRUCTIONS Page 10 omega com...

Страница 11: ...y OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limite...