background image

5

Safety Instructions

2

Section 2 - Safety instructions

Receipt and unpacking

Unpack the device without damaging it and check whether the device type corresponds to the one ordered. The packing should 

always follow the device until this has been permanently mounted.

Environment

The device is manufactured for indoor use. Avoid direct sunlight, dust, high temperatures, mechanical vibrations and shock, as 

well as rain and heavy moisture. If necessary, heating in excess of the stated limits for ambient temperatures should be avoided 

by way of ventilation. 
The device may be used in Overvoltage Category II, Pollution Degree 2 at an altitude up to 2000 m.

Mounting

Only qualified technicians who are familiar with the technical terms, warnings, and instructions in this installation guide and 

who are able to follow these should connect the device. Only devices which are undamaged and free of moist and dust may be 

installed. The device may be installed and supplied by Omega DRST series only. 

Should there be any doubt as to the correct handling of the device, please contact your local distributor or, alternatively, 

Calibration and Adjustment

During calibration and adjustment, the measuring and connection of external voltages must be carried out according to the 

specifications of this manual. The technician must use tools and instruments that are safe to use.

Cleaning

When disconnected, the device may be cleaned with a cloth moistened with distilled water.

IECEx, ATEX installation in Zone 2

IECEx DEK 13.0026 X  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Ex nA IIC T5 Gc
DEKRA 13ATEX0098 X  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  II 3 G Ex nA IIC T5 Gc

For safe installation the following must be observed

The device must be installed by qualified personnel who are familiar with the national and international laws, directives and 

standards that apply to this area.
Year of manufacture can be taken from the first two digits in the serial number.
The devices must be installed in a suitable enclosure providing a degree of protection of at least IP54 according to EN60529, 

taking into account the environmental conditions under which the equipment will be used.
To prevent ignition of the explosive atmospheres do not separate connectors when energized and an explosive gas mixture is 

present.
To avoid the risk of explosion due to electrostatic charging of the enclosure, do not handle the units unless the area is known to 

be safe, or appropriate safety measures are taken to avoid electrostatic discharge.

Liability

To the extent the instructions in this manual are not strictly observed, the customer cannot advance a demand against Omega 

A/S that would otherwise exist according to the concluded sales agreement.

Содержание DRST-CM

Страница 1: ...e mail info omega com For latest product manuals www omegamanual info DRST CM Communication Enabler TM Shop online at omega com User sGuide ...

Страница 2: ...specifications without notice omega com info omega com Servicing North America U S A Omega Engineering Inc Headquarters Toll Free 1 800 826 6342 USA Canada only Customer Service 1 800 622 2378 USA Canada only Engineering Service 1 800 872 9436 USA Canada only Tel 203 359 1660 Fax 203 359 7700 e mail info omega com For Other Locations Visit omega com worldwide ...

Страница 3: ...ection 3 Safety Instructions 6 Section 4 Applications 7 Section 5 Technical Characteristics 7 Section 6 Mounting Installation Programming 8 Section 7 Mounting on a DRST device 8 Section 8 Order 8 Section 9 Electrical Specifications 9 10 Section 10 Modbus Parameter settings 11 12 Section 11 Modbus Settings Routing Diagram 13 14 ...

Страница 4: ...ction provided by the equipment may be impaired GENERAL WARNING Until the device is fixed do not connect hazardous voltages to the device The following operations should only be carried out on a disconnected device and under ESD safe conditions General mounting connection and disconnection of Modbus cable Troubleshooting the device HAZARD OUS VOLTAGE Triangle with an exclamation mark Read the manu...

Страница 5: ...ltages must be carried out according to the specifications of this manual The technician must use tools and instruments that are safe to use Cleaning When disconnected the device may be cleaned with a cloth moistened with distilled water IECEx ATEX installation in Zone 2 IECEx DEK 13 0026 X Ex nA IIC T5 Gc DEKRA 13ATEX0098 X II 3 G Ex nA IIC T5 Gc For safe installation the following must be observ...

Страница 6: ... DRST CM display can be used to read the process signal simulate the output signal indicate sensor errors and internal module errors Section 5 Technical Characteristics DRST CM has full DRSL DISPLAY functionality for unit programming process signal monitoring and diagnostics handling Modbus RTU protocol is supported using a serial RS 485 communication wiring Multidrop half duplex connection via sh...

Страница 7: ...e LCD dot display Line 1 can e g show the scaled process value Line 2 can e g show the selected engineering unit Line 3 can e g show the analog output or TAG no Line 4 shows status for communication and e g signal trending RJ45 Modbus Connector Pin 5 RS485 A line Pin 4 RS485 B line Pin 8 RS485 GND and shield Section 8 Order Type Description DRST CM DRSL DISPLAY Communication enabler Configmate int...

Страница 8: ... response time 50 Hz 20 ms Signal type RS 485 half duplex Serial protocol Modbus RTU Modbus mode RTU slave Devices on an RS485 line Up to 32 without a repeater Data rates baud 2400 4800 9600 19200 38400 57600 115200 Automatic baudrate detection Yes can be configured ON or OFF Parity Even Odd None Stop bit s 1 or 2 Digital adressing 1 247 Response delay 0 1000 ms Approvals EMC 2004 108 EC EN 61326 ...

Страница 9: ...ST DRST DRST DRST CM DRST CM IP54 DRST DRST DRST DRST CM DRST CM DRST CM DRST DISPLAY DRST CM DRST CM DRST CM T T T Modbus RTU Zone 2 Cl 1 Div 2 gr A D Safe Area Modbus RTU Gateway Gateway Modbus RTU Ethernet Modbus TCP IP PLC DCS HMI PC PLC DCS HMI PC Modbus RTU PLC DCS HMI PC Access Point ...

Страница 10: ...cepted by all slaves but numbers 1 247 are addresses of specific devices With the exception of broadcast messages a slave device always responds to a Modbus message so the master knows the message was received DRST CM Supported Modbus Function Codes The Function Code defines the command that the slave device is to execute such as read data accept data report status Some function codes have subfunc...

Страница 11: ...onse delay 0 1000 ms 0 ms default Modbus slave addressing range 1 247 247 default address Modbus Parameter Storage Saved in non volatile memory in the DRST CM device Factory Default Values are marked in bold Modbus RTU segment line termination A 120 Ohm resistor should be installed on both ends of a RS485 Modbus RTU segment loop to prevent signal echoes from corrupting data on the line DRST CM Mod...

Страница 12: ...rticular device Omega A S DRST CM Local Menu xlsx DRST CM local submenu V0R9 Monitor SCROLLING HELPTEXTS 40 0 0000 correct No No xxxx 1 Set correct password OK PASSW OK ADV SET OK XXXX 2 Enter advanced setup menu 10 4mA 1 2 Yes x 3 Enter Language setup o V Enter Password setup v v v Enter Simulation mode 9999 YES Perform Process calibration 0000 NO Enter Display setup Perform Memory operations MEM...

Страница 13: ...5 No Returns to Monitor upon succesful Modbus write command OFF STATUS 1 v YES NO STATUS 1 Only if automatic baudrate detection is enabled ORIEN NO ROT DEV OK Monitor 13 The gray shaded menus texts are only shown for guidance and are not part of the DRST CM specific submenu The Modbus submenu is located somewhere in the menu structure of any host device supporting DRST CM The actual place is defin...

Страница 14: ...GA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to mishandling improper interfacing operation outside of design limits improper repair or unauthorized modification This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows ...

Страница 15: ...rs M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U Industrial pH Conductivity Equipment DATA ACQUISITION M U Communications Based Acquisition Systems M U Data Logging Systems M U Wireless Sensors Transmitters Receivers M U Signal Conditioners M U Da...

Отзывы: