5
Safety Instructions
2
Section 2 - Safety instructions
Receipt and unpacking
Unpack the device without damaging it and check whether the device type corresponds to the one ordered. The packing should
always follow the device until this has been permanently mounted.
Environment
The device is manufactured for indoor use. Avoid direct sunlight, dust, high temperatures, mechanical vibrations and shock, as
well as rain and heavy moisture. If necessary, heating in excess of the stated limits for ambient temperatures should be avoided
by way of ventilation.
The device may be used in Overvoltage Category II, Pollution Degree 2 at an altitude up to 2000 m.
Mounting
Only qualified technicians who are familiar with the technical terms, warnings, and instructions in this installation guide and
who are able to follow these should connect the device. Only devices which are undamaged and free of moist and dust may be
installed. The device may be installed and supplied by Omega DRST series only.
Should there be any doubt as to the correct handling of the device, please contact your local distributor or, alternatively,
Calibration and Adjustment
During calibration and adjustment, the measuring and connection of external voltages must be carried out according to the
specifications of this manual. The technician must use tools and instruments that are safe to use.
Cleaning
When disconnected, the device may be cleaned with a cloth moistened with distilled water.
IECEx, ATEX installation in Zone 2
IECEx DEK 13.0026 X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ex nA IIC T5 Gc
DEKRA 13ATEX0098 X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . II 3 G Ex nA IIC T5 Gc
For safe installation the following must be observed
The device must be installed by qualified personnel who are familiar with the national and international laws, directives and
standards that apply to this area.
Year of manufacture can be taken from the first two digits in the serial number.
The devices must be installed in a suitable enclosure providing a degree of protection of at least IP54 according to EN60529,
taking into account the environmental conditions under which the equipment will be used.
To prevent ignition of the explosive atmospheres do not separate connectors when energized and an explosive gas mixture is
present.
To avoid the risk of explosion due to electrostatic charging of the enclosure, do not handle the units unless the area is known to
be safe, or appropriate safety measures are taken to avoid electrostatic discharge.
Liability
To the extent the instructions in this manual are not strictly observed, the customer cannot advance a demand against Omega
A/S that would otherwise exist according to the concluded sales agreement.