Omega National 90026WHI1 Скачать руководство пользователя страница 2

TOOLS REQUIRED

:

1. 

Drill,  electric  or  ratchet  drive  with  1-1/4" 

wood  bit  (to  drill  an  access  hole  in  the 

cabinet or kitchen wall for the electric power 

line)

2. 

1/4" metal drill bit

3. 

One 3/8" nut driver (to secure hood mount-

ing  screws  to  the  cabinet  and  hood  sheet 

metal parts)

4. 

Pliers (for opening knockouts)

5. 

Pencil,  ruler  and  level  for  marking  cabinet 

locations

6. 

Saber  saw  or  keyhole  saw  for  cutting  the 

wall or cabinet openings

7. 

Straight blade screwdriver and Phillips head 

screwdriver

INSTALLATION OF EXHAUST UNIT

:

NOTE:    When  installing  90026WHI1  into  liner 

with (4) mounting studs, mount unit from below 

aligning studs  with appropriate  holes.    Secure 

with  nuts  provided.    For  installation  of  liners 

without mounting studs, proceed to step #1.

1. 

Set  Power  Module  into  place  on  top  of 

installed liner (refer to liner instructions), line 

up  the  mounting  holes  and  fasten  in  place 

using  (4)  10-24  x  1/2”  bolts  and  nuts  sup-

plied.

2. 

Cut out additional opening in wall and roof 

as required.

3. 

Remove  junction  box  cover  from  exhaust 

unit.

4. 

Pull wiring through cutout in wall.  Feed wir-

ing through access hole in junction box and 

connect per wiring diagram.

5. 

Install and align duct.  The ducting system is 

not included with your Exhaust Unit.  These 

items must be purchased separately.

6. 

Make  electrical  connections  according  to 

the latest National Electrical Code and appli-

cable local ordinances.

7. 

Replace junction cover.

8. 

Seal holes around ventilating pipe and wir-

ing  passing  through  ceilings  or  walls  with 

caulking or insulation to prevent air loss.

9. 

Install decorative range hood cover.

W

ARNING!!

      To reduce the risk of fire, use only metal 

ductwork.

W

ARNING!!

      Do not use this fan with any solid-state 

speed control device.

W

ARNING!!

          TO  REDUCE  THE  RISK  OF A  RANGE 

TOP GREASE FIRE: 1) Never leave surface units unat-

tended at high settings. Boilovers cause smoking and greasy 

spillovers that may ignite. Heat oils slowly on low or medium 

settings. 2) Always turn hood ON when cooking at high heat 

or  when  cooking  flaming  foods.  3)  Clean  ventilating  fans  fre-

quently. Grease should not be allowed to accumulate on fan or 

filter. 4) Use proper pan size. Always use cookware appropriate 

for the size of the surface element.

W

ARNING!!  

    TO REDUCE THE RISK OF INJURY TO 

PERSONS IN THE EVENT OF A RANGE TOP GREASE 

FIRE,  OBSERVE  THE  FOLLOWING:  SMOTHER  FLAMES 

with  a  close  fitting  lid,  cookie  sheet,  or  metal  tray,  then  turn 

off  the  burner.  BE  CAREFUL  TO  PREVENT  BURNS.  If  the 

flames  do  not  go  out  immediately,  EVACUATE  AND  CALL 

THE  FIRE  DEPARTMENT.  NEVER  PICK  UP  A  FLAMING 

PAN YOU MAY BE BURNED. Do not use water, INCLUDING 

WET  DISHCLOTHS  OR  TOWELS  -  A  VIOLENT  STEAM 

EXPLOSION WILL RESULT. Use an extinguisher ONLY if: 1) 

You know you have a class ABC extinguisher, and you already 

know how to operate it. 2) The fire is small and contained in the 

area where it started. 3) The fire department is being called. 4) 

You can fight the fire with your back to an exit.

Page 2

Form OME-004 02/06 628019A

©2006 Omega National Products, LLC.

Содержание 90026WHI1

Страница 1: ...the service panel Installation work and electrical wiring must be done by quali fied person s in accordance with the National Electrical Code and all applicable codes and standards including fire rate...

Страница 2: ...e junction cover 8 Seal holes around ventilating pipe and wir ing passing through ceilings or walls with caulking or insulation to prevent air loss 9 Install decorative range hood cover WARNING To red...

Страница 3: ...t the fol lowing parts are needed 90354DUC1 Kit includes all parts required for this installation as shown below Optional Custom Wood Grille kit Unassembled Accommodates sizes to 6 x 10 90353OUF2 Oak...

Страница 4: ...date EXCLUSIONS This warranty does not cover consumable parts such as charcoal filters and light bulbs This warranty does not apply if this product has been subjected to faulty installation misuse ab...

Страница 5: ...se de l appareil et les travaux d lectricit doivent tre effectu s par des personnes qualifi es conform ment la r glementation en vigueur notamment les normes de la con struction ayant trait la protect...

Страница 6: ...z jamais les l ments de surface allum s haute temp rature Les d bordements peu vent causer de la fum e et occasionner des coulements de graisse inflammables L huile doit tre chauff egraduellement bass...

Страница 7: ...isation au trav ers de soffit les pi ces suivantes sont n cessaires 90354DUC1 Le kit inclut toutes les pi ces exig es pour cette installation comme mon tr ci dessous Page 7 Grille en M tal Collier R g...

Страница 8: ...ommence la date d achat original Afin d tablir la date d achat original gardez l acte de vente dat le ch que d command ou toute autre vidence de la date originale d achat EXCLUSIONS Cette garantie ne...

Страница 9: ...l Installation work and electrical wiring must be done by quali fied person s in accordance with the National Electrical Code and all applicable codes and standards including fire rated construction W...

Страница 10: ...ctions according to the latest National Electrical Code and appli cable local ordinances 9 Replace junction cover 10 Seal holes around ventilating pipe and wir ing passing through ceilings or walls wi...

Страница 11: ...onal parts required should be pur chased as needed To install this unit ductless through soffit the fol lowing parts are needed 90355DUC1 Kit includes all parts required for this installation as shown...

Страница 12: ...nal purchase Rangaire will provide at no charge replacement parts for any parts of your kitchen ventilating equipment other than consumable parts which are defective in material or workmanship The rep...

Страница 13: ...l et les travaux d lectricit doivent tre effectu s par des personnes qualifi es conform ment la r glementation en vigueur notamment les normes de la con struction ayant trait la protection contre les...

Страница 14: ...bo te de jonc tion 10 Bouchez les trous autour du conduit de ven tilation et des c bles passant au travers de plafonds ou de murs avec du calfeutrage ou du mat riau isolant pour emp cher la perte d a...

Страница 15: ...est inclus avec l unit 90039WHI1 Enraisond unegrandevari t d installations les pi ces additionnelles n cessaires devrant tre achet es selon besoin Pour installer cette unit sans canalisation au trav e...

Страница 16: ...E OMEGA NATIONAL PRODUCTS LLC Pi ces Pendant une p riode d un 1 an apr s date d achat original Rangaire fournira aucuns frais des pi ces de rechange pour toutes les pi ces de votre quipement d a ratio...