background image

Optics

Warnings and Cautions

!

USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF 
PROCEDURES OTHER THAN THOSE SPECIFIED HERE MAY RESULT IN 
HAZARDOUS RADIATION EXPOSURE.

!

DO NOT LOOK AT THE LASER BEAM COMING OUT OF THE LENS OR VIEW 
DIRECTLY WITH OPTICAL INSTRUMENTS - EYE DAMAGE CAN RESULT.

!

USE EXTREME CAUTION WHEN OPERATING THE LASER.

!

NEVER POINT THE LASER BEAM AT A PERSON.

!

KEEP OUT OF REACH OF ALL CHILDREN.

PATENT NOTICE:

 U.S. PAT. B1 5,368,392; 5,524,984; 5,727,880; 5,465,838; 5,823,678; 5,823,679. 

Other U.S. and Foreign Patents and Applications Pending. Manufactured in Italy. Licensed by Omega 
Engineering, Inc.

Distance: Sensor to Object (mm)

Distance: Sensor to Object (in)

25

12

35

23

35

75

67

157

100

238

4.0

2.7

1.4

.9

.5

1

1.4

3

6.2

9.4

0

225 500 625

1000

2000

3000

0

9

20 25

40

80

120

OSP100XL

OSP100, OSP100L
Nominal D:S = 12:1

Nominal D:S = 30:1

* Spot size measured
at 90% energy

S

p

o

D

IA

(m

m

)

S

p

o

D

IA

(i

n

)

OSP100L and OSP100LX models only

WARNING

DO NOT ATTEMPT TO OPEN THE LASER SIGHT MODULE.

(THERE ARE NO USER SERVICEABLE PARTS IN THE MODULE).

A

V

O

ID
 E
X

P

O

S

U

R

E

 

L

A

S

E

R

 R
A

D

IA

T

IO
N

 

IS
 E
M

IT

T

E

D

 F

R

O

M

 

T

H

IS
 A
P

E

R

T

U

R

E

LASER RADIATION - DO NOT STARE INTO BEAM

MAX.OUTPUT<1mW, WAVELENGTH 630-670nm 

CLASS I I LASER PRODUCT

COMPLIES WITH 21CFR CHAPTER 1, SUBCHAPTER J

C A U T I O N

LASER RADIATION DO NOT STARE 

INTO BEAM OR VIEW DIRECTLY 

WITH OPTICAL INSTRUMENTS.

MAX.OUTPUT<1mW, WAVELENGTH 630-

670nm, CLASS 2 LASER PRODUCT 

CONFORMS TO IEC825-1:1993 

Operational Flow Chart

Laser pointer enable/disable

Display external probe/infrared measurements

Backlight ON/OFF

Hold measurements in lower display. Refresh hold.

Circular switch between Average, Minimum or Maximum measurements on lower display.

Activate 2nd function keys.

Switch engineering temperature units.

Set mode for HIGH alarm.

Set mode for LOW alarm.

Set mode for Emissivity.

Increase digit.

Decrease digit.

Store value and return in normal mode.

NORMAL MODE KEYPAD

OSP100 uses a 

High Quality custom display

Probe

Lamp

Min/Max

Hold

2nd

2nd

Probe

Lamp

Hold

Min/Max

Set 

e

HI

LO

°C/°F

+

=

2nd

2nd

+

+

=

=

=

2nd

+

SET MODE KEYPAD

FOOD (HACCP) 

To control and supervise production phases, handling, transport, and 

conservation of cooked and refrigerated foods.

AUTOMOTIVE 

To check engine, bearings, muffler, brakes, etc.

INDUSTRIAL & ELECTRICAL 

Bearings, motors, valves, switches, insulation, etc.

HVAC/R 

Heating & cooling systems, thermal insulation, radiators, ducts, etc.

Applications

Probe

2nd

Lamp

Hold

Min/Max

°C/°F

Set  

e

HI

LO

Set Alarm

e

+  -

+  -

°F

°C

HAL

LAL

Set

Lock

2nd

+

Laser beam mode: Continuous / Flashing (economy mode).

Basic functions

Enhanced functions

External probe operation. Connect the Pt100 resistance thermometer to the appropriate 
connector. Switch the unit on and press the [Probe] key. The “EXT” message will be 
displayed on the lower display for Pt100 readings. 
Hold measurement. Press the [HOLD] key to freeze the displayed temperature. The hold 
value will be displayed in lower display. On the main display the temperature is that actually 
measured. Press the key again to refresh the Hold indication.
The Hold indication is refreshed by pressing the trigger for more than 1 sec with the unit in 
measuring mode and releasing the trigger. Switch the OSP100 off by pointing the unit to 
the target  to recall the last value when you switch the unit on.
Select Average (AVG), Minimum (MIN) and Maximum (MAX) values. Press the [Min/Max] 
key until the appropriate message is displayed. The unit will refresh the values of each 

nd

measurement from the power on. To reset the values, press the [2 ] key or switch the unit 
off and on.

nd

Emissivity adjustments. Press in sequence the [2 ] and [Set 

e

] keys to change  the emissivity 

from 0.30 to 1.00 with 0.01 resolution. On the lower display the set value is shown. Press 
the [UP] and [DOWN] keys to increase and decrease the emissivity. Press the [ENTER] key to 
store and return on the normal mode measurement.

nd

Set low (LAL) and high (HAL) alarms. Press in sequence the [2 ] and [HI] keys to change 
the High alarm set point.. “HAL” will be seen on the display. The stored High alarm will be 
displayed. The High alarm level is to be set by adjusting the [UP] or [DOWN] keys. Press the 
[HI] key to enable/disable the acoustic alarm. Press the [ENTER] key to store the displayed 

nd

value and return to normal mode. Press in sequence the [2 ] and [LO] keys to change the 
Low alarm set point..“LAL” will be seen on the display. The Low alarm level is to be set by 
adjusting the [UP] or [DOWN] keys. Press the [LO] key to enable/disable the acoustic alarm. 
Press the [ENTER] key to store the displayed value and return in normal operation mode. 
When the measurement is inside the programmed alarm band, the “LAL” or “HAL” symbol 
will be lit and an intermittent beep will be emitted.

To take a temperature reading, point the unit at the target you wish to measure. Push and 
keep the trigger pushed. The current temperature reading is displayed. Last reading before 
previous switching-off is displayed in lower display. Release the trigger. A “Lock” symbol on 
the LCD will be displayed and the Hold value is refreshed. OSP100 will remain switched on 
for 40 seconds. The time will reset if a key is pressed or a serial communication message is 
sent.. Press and release quickly the trigger to switch the instrument off. 
The OSP100L and 100XL models can be supplied with a laser sighting with either a “laser 
dot” to read the target area center or with a “laser circle” to read the target area. Press the 
[*] key to enable/disable the laser. The message “LAS EN” or “LAS DIS” will be displayed. 
When enabled, the laser can be switched on by pressing the trigger button for more than 
1 sec. The laser will automatically switch off when the trigger button is released. The 
emission indicator symbol (*) will appear on lower display.

nd

Press in sequence the [2 ] and [*] keys to change the laser beam mode between 
Continuous and Flashing (to increase battery expected life) mode.
Press the [Lamp] key to switch back-light on or off.

nd

Press in sequence the [2 ] and [°C/°F] keys to change the engineering units between °C 
and °F.

The OSP100 is the ideal tool for periodic process monitoring and for measuring 
temperature quickly and easily, by contact with the target or from distance. An optional 
laser pinpointing method simplifies the identification of the measuring surface area.
The OSP100 is the essential tool for the prevention of a variety of temperature related 
equipment or process malfunctions. It can prevent serious damage to bearings, motors, 
valves, electrical switches and distribution conductors, cooling or steam traps, thermal 
insulation deterioration, hot spots, engine performances, extrusion heads, depleted 
refrigeration system, etc.
The instrument is rugged, accurate and compact for fast and easy periodic process 
monitoring, to control quality and/or supervise production phases of cooked and 
refrigerated foods.

Specifications

General

!

Spectral band: 8-14 

m

m

!

Display: 3 ½ digit custom backlighted LCD plus labels for max, min, emissivity, Hold, °C, °F, 
low battery.

!

Resolution: 0.1°C up to 199.9°C. 1°C otherwise.

!

Response time: 500 ms

!

Target pinpointing: sight dot or circular laser sighting (L and XL models only)

!

Emissivity: adjustable from 0.30 to 1.00

!

Auto Power Off: Automatic power Off if no key is pressed for more than 40 sec.

!

Alarm: low and high alarm with visual and acoustic beeper

!

Signal processing: °C/°F, average, hold, max, min (where applicable)

!

Accuracy IR channel: 

range from 23°C to f.s. : ±1% of reading or ±1°C whichever is greater
range from -32°C to 23°C : ±1.5°C

!

RTD channel: Pt100 IEC751 

a

385 (probe excluded)

Input range: from -32°C to 520°C
Accuracy: ±0.3% of rdg or  ±0.3°C whichever is greater

!

Laser sight:: 

Wavelength: 650nm, Beam diameter: 3mm, Beam divergence: <0.5mrad; 
Laser indicator: asterisk on display

!

FDA Classification: Class II, Complies with 21CFR Chapter 1, Subchapt.er J

!

Safety Classification: Class 2

!

Power supply: alkaline or rechargeable battery

!

Battery life: 60 h (back light & laser off)

!

Ambient temperature: -10 to +45°C / 10-95% RH non condensing

!

Storage temperature: -30°C to +60°C

!

Dimensions and weight: 180x140x45 mm   380g nett

When alkaline batteries are used, DO NOT connect power module to input jack.

CE certifications

This instrument conforms to the following standards: 
EN 50081-1: 1992, Electromagnetic emissions
EN 50082-1: 1992, Electromagnetic susceptibility

Отзывы: