background image

Servicing North America:

USA:

One Omega Drive, P.O. Box 4047

ISO 9001 Certified

Stamford, CT 06907-0047
TEL: (203) 359-1660

FAX: (203) 359-7700

e-mail: [email protected]

Canada:

976 Bergar
Laval (Quebec) H7L 5A1
TEL: (514) 856-6928

FAX: (514) 856-6886

e-mail: [email protected]

For immediate technical or application assistance:

USA and Canada:

Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA

®

Customer Service: 1-800-622-2378 / 1-800-622-BEST

®

Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN

®

TELEX: 996404   EASYLINK: 62968934   CABLE: OMEGA

Mexico

TEL: (001)800-TC-OMEGA

SM

FAX: (001) 203-359-7807 

En Español: (001) 203-359-7803

e-mail: [email protected]

Servicing Europe:

Benelux:

Postbus 8034, 1180 LA Amstelveen, The Netherlands
TEL: +31 (0)20 6418405

FAX: +31 (0)20 6434643

Toll Free in Benelux: 0800 0993344
e-mail: [email protected]

Czech Republic:

Rudé armády 1868, 733 01 Karviná 8
TEL: +420 (0)69 6311899

FAX: +420 (0)69 6311114

e-mail: [email protected]

France:

9, rue Denis Papin, 78190 Trappes
TEL: +33 (0)130 621 400

FAX: +33 (0)130 699 120

Toll Free in France: 0800406342
e-mail: [email protected]

Germany/Austria:

Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
TEL: +49 (0)7056 9398-0

FAX: +49 (0)7056 9398-29

Toll Free in Germany: 0800 TC-OMEGA

SM

e-mail: [email protected]

United Kingdom:

One Omega Drive

ISO 9002 Certified

River Bend Technology Centre
Northbank, Irlam
Manchester M44 5EX United Kingdom
TEL: +44 (0)161 777 6611

FAX: +44 (0)161 777 6622

Toll Free in the UK: 0800 488 488
e-mail: [email protected]

omega.com

OMEGAnet

SM

On-Line Service 

Internet e-mail

http://www.omega.com 

[email protected]

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly
pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every
appropriate device upon certification.
The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability
for any errors it contains, and reserves the right to alter specifications without notice.

WARNING: 

These products are not designed for use in, and should not be used for, patient connected applications.

This  device  is  marked  with  the  international  caution  symbol.      It  is  important  to  read  the  Setup Guide  before  installing  or
commissioning this device as it contains important information relating to safety and EMC.

Содержание iDRN-PS-1000

Страница 1: ...L N USA MADE IN User sGuide www omega com e mail info omega com Shop on line at iDRN PS 1000 UNIVERSAL SWITCHING POWER SUPPLY Compact DIN Rail 24 Volt...

Страница 2: ...6 D 75392 Deckenpfronn Germany TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29 Toll Free in Germany 0800 TC OMEGASM e mail germany omega com United Kingdom One Omega Drive ISO 9002 Certified River Bend Tec...

Страница 3: ...5 3 2 Mounting on DIN Rail 6 3 3 Removal of Unit 7 4 Input and Output Connections 8 4 1 Block Diagram 8 4 2 Wiring for 115 Vac Single Phase 9 4 3 Wiring for 230 Vac Two Phase 10 5 Specifications 11 In...

Страница 4: ...icant iDRN features include Tested isolation primary to output Recessed live parts and connector screws 35mm DIN rail mounting Wide input voltage tolerances Protective varistor input shunt Input AC sp...

Страница 5: ...Furthermore to provide protection against excessive energy being drawn from the mains supply in case of a fault in the equipment an overcurrent protection device shall be installed The Protective Con...

Страница 6: ...packing of the power supply is recommended For units that must be shipped installed on the rail additional bracing to resist transportation shocks is recommended Do not attempt to install or connect t...

Страница 7: ...be a minimum of 1 25mm spacing to allow sufficient air circulation for proper cooling Figure 3 1 Mounting INSTALLATION AND REMOVAL 3 5 DC POWER OUT AC POWER IN DC POWER IN SIGNAL INPUT DC POWER IN SI...

Страница 8: ...N Rail To install unit onto DIN Rail 1 Tilt unit position mounting slot onto DIN Rail as shown 2 Push unit towards DIN Rail and it will snap into place Figure 3 2 Mounting on 35mm DIN Rail INSTALLATIO...

Страница 9: ...3 7 3 3 Removal of Unit 1 Insert flat screw driver into tab and push downwards 2 Unit will detach from DIN Rail Figure 3 3 Removal of Unit INSTALLATION AND REMOVAL...

Страница 10: ...ed all output connections Failure to do so may result in injury This device must only be installed electrically by a specially trained electrician with corresponding qualifications Warning To avoid po...

Страница 11: ...c Single Phase L N Output Voltage for shielded wire connections if necessary Earth FUSE 1 LINE Switch NEUTRAL Earth Switch USE A SWITCH TO APPLY 24V POWER TO THE LOAD IF THE CAPACITANCE OF THE LOAD WI...

Страница 12: ...CTIONS 4 10 L N Output Voltage for shielded wire connections if necessary Earth FUSE 1 L1 Switch L2 Earth FUSE 2 Switch USE A SWITCH TO APPLY 24V POWER TO THE LOAD IF THE CAPACITANCE OF THE LOAD WILL...

Страница 13: ...age 24Vdc 2 850mA Resistive Load Output Wattage 20 Watts For higher output wattage greater than 20 watts follow the chart on section 7 Figure 6 2 Ripple less than 100 mVrms Operating Indicator Front P...

Страница 14: ...ize Height 3 55 90mm Width 0 99 25mm Depth 4 38 111mm Weight 0 3 lbs 0 14 kg Equipment Type CLASS I Overvoltage CAT II Pollution Degree 2 Insulation input to ouput Dielectric strength to 2500V transie...

Страница 15: ...DIMENSIONS 6 13...

Страница 16: ...tage of 100V the maximum ambient temperature allowed is 40 C Figure 6 2 Temperature Derating Graph MAXIMUM POWER OUTPUT INPUT AC VOLTAGE AMBIENT TEMPERATURE C 120V 265V 115V 110V 105V 100V 25 C 5 C 30...

Страница 17: ...NOTES 15...

Страница 18: ...NOTES 16...

Страница 19: ...special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2...

Страница 20: ...locity Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industr...

Отзывы: