SPECIFICATIONS 

ELECTRICAL 

Temperature Scale: Celsius or Fahrenheit user-selectable 
Measurement Range: 
Pt385(100

) -200°C to 800°C, (-328°F to 1472°F) 

Pt3916/Pt3926(100

)  -200°C  to  630°C,  (-328°F  to 

1166°F) 
Resolution: 0.1°C or 0.2°F 
Accuracy: 
Accuracy is specified for operating temperatures over the 
range  of  18°C  to  28°C  (64°F  to  82°F),  for  1  year,  not 
including RTD probe error. 
±(0.05% rdg + 0.2°C) on °C scale 
±(0.05% rdg + 0.4°F) on °F scale 
Temperature Coefficient: 
0.1  times  the  applicable  accuracy  specification  per  °C 
from  0°C  to  18°C  and  28°C  to  50°C  (32°F  to  64°F  and 
82°F to 122°F). 
Input Protection: 
24V  dc  or  24V  ac  rms  maximum  input  voltage  on  any 
combination of input pins. 
Maximum  Differential  Common  Mode  Voltage 
(Maximum Voltage between T1 and T2 during meas-
urement): 
1volt. 
Reading Rate: 1 time per second. 
Input Connector: 
Accepts  for  RTD  3  wires  or  4  wires  subminiature 
4-Prong  type  connectors  (flat  blades  spaced  7.9mm, 
center to center). 

  Wireless Features: 

Frequency range: 910~920MHz (HH804W) 

868.1~868.5MHz (HH804WE) 

Low current consumption less than 1mA. 
The  transmitting  distance  can  reach  25M  without  mag-
netic interference. 
 

ENVIRONMENTAL 

Ambient Operating Ranges: 
0°C to 50°C (32°F to 122°F) <80% R.H. 
Storage Temperature: 
-20°C to 60°C (-4°F to 140°F) <70% R.H. 
 

GENERAL 

Display: 
4½ digit liquid crystal display (LCD) with maximum 
reading of 19999. 
Overload: “----.-” or “OL” is display. 
Battery: 
1.5V x 4 PCS (SIZE AAA) UM-4 R03. 
Battery Life: 
200 hours typical with carbon zinc battery. 
Auto power off: 30 minutes, press power key to resume 
operation. 
Dimensions: 
160mm(H) x83mm(W) x 38mm(D). 
Weight: Approx. 255g including batteries. 

OPERATING INSTRUCTIONS 

1. “ ” Power Button 

The “

 key turns the thermometer on or off. In the SET 

mode  cannot  be  powered  off.  Exit  SET  mode  to  power 
off. 
 
APO function mode 
Press “

 power key for more than 6 seconds to disable 

the  auto-power  function.  The  display  will  show  “APO 
OFF”. 
 

2. °C/°F Selecting the Temperature Scale (Main 

display) 

Reading the main displayed in either degrees Celsius(°C) 
or  degrees  Fahrenheit(°F).  When  the  thermometer  is 
turned on, it is set to the temperature scale that was in use 
when the thermometer was last turned off. To change the 
temperature scale, press the “°C/°F” key. 
 

3. “ ” Display Back-Light 

Press the “

” key to turn on or turn off the Back-Light. 

 

4. T1 T2/T1-T2 Main display Input Selection 

The input selection indicates which input is selected for 
main display; T1 probe, T2 probe or the difference be-
tween the two probes (T1-T2). When the thermometer is 
turned on, it is set to T1, when main display input se-
lected T1, then T1 input can select alternate of probe by 
pressing Pt385/Pt3926/Pt3916 key switch. 
 

5. TYPE(Pt385/Pt3926/Pt3916) Input RTD 

Probe Select (only Main display) 

The  “TYPE”  key  switches  the  T1  input  to  select  the 
Pt385, Pt3926 or Pt3916 RTD probe as input, when main 
display  input  selected  T1.  When  the  thermometer  is 
turned  on,  it  is  set  to  the  probe  selected  that  was  in  use 
when the thermometer was last turned off. 
 

6. MIN/MAX with Time record mode 

(only Main display) 

Press  “MIN/MAX”  key  to  enter  the  MIN  MAX  Re-
cording mode, (displays the Maximum reading with time, 
Minimum  reading  with  time  and  Average  reading stored 
in  record  mode).  In  the  this  mode  the  automatic 
power-off feature is disabled and “

 key, “°C/°F” key, 

“REL”  key,  “SET”  key,  “Hi/Lo  Limits”  key  and  main 
display  “T1  T2  T1-T2”  key,  “TYPE”  key  are  disabled. 
The beeper emits a tone when a new minimum or maxi-
mum value is recorded. 
Press “MIN/MAX” key to cycle through the MAX, MIN 
and  AVG  readings.  If  an  overload  is  recorded,  the  aver-
aging  function  is  stopped.  In  this  mode,  press  the 
“HOLD” key to stop the recording of readings, all values 
are held, press again to restart recording. 
To prevent accidental loss of MIN, MAX and AVG data, 
this mode can only be cancelled by pressing and holding 
the  “MIN/MAX”  key  for  2  seconds.  All  recorded  read-
ings are erased. 

7. REL Relative mode (only Main display) 

Press the “REL” key to enter the relative mode, zero the 
display,  and  store  the  displayed  Reading  as  a  reference 
value.  REL  is  shown  on  the

 

display.  Press  “REL”  key 

again  to  exit  the  relative  mode.  The  relative  reference 
value  can also  be  entered  by  the user.  (See  “SET  mode” 
later in this manual). When the desired relative value has 
been entered, press “REL” key to enter the relative mode 
and  than  press  “SET”  key  use  the  entered  relative  value 
as  a  reference  value.  Press  “REL”  key  again  to  exit  the 
relative  mode.  In  the  relative  mode,  the  value  (can  not 
>±1999.9  counts)  shown  on  the  LCD  is  always  the  dif-
ference  between  the  stored  reference  and  the  present 
reading. 
 
8. HOLD mode (only Main display) 
Press the “HOLD” key to enter the Data Hold mode, the 
“HOLD” annunciator is displayed. When HOLD mode is 
selected,  the  thermometer  held  the  present  readings  and 
stops  all  further  measurements.  Press  the  “HOLD”  key 
again  to  cancel  HOLD  mode  causing  thermometer  to 
resume  taking  measurements.  In  the  MIN/MAX  re-
cording  mode,  press  “HOLD”  key  to  stop  the  recording. 
Press  “HOLD”  key  again  to  resume  recording.  (Previ-
ously recorded read are not erased). 
 

9.  SET  mode  (Relative  value  set,  Time  set  and 

Hi/Lo Limits value set) 

9.1  Press  the  “SET”  key  to  enter  relative  values  SET 

mode (Press “ENTER” key  to  skip  setting  relative 
value).  =  =  =  =.=  is  displayed  on  the  main  display. 
The  relative  value  is  entered  via  overlay  numbers, 
press overlay “ENTER” key to store the relative value, 
and advance to elapsed time set mode. 

9.2  Elapsed  time  set  mode,  (Press  ENTER  key  to  skip 

Elapsed time set mode) =.= =  =  : = = is  displayed  in 
second  and  third  display.  Time  (hours,  minutes,  sec-
onds)  value  is  entered  via  overlay  numbers,  press 
overlay  “ENTER”  key  to  store  time  value.  Elapsed 
time starts from set time value. 

9.3 Hi Limit value set mode, (Press “ENTER” key to skip 

Hi  Limit  value  set  mode),  =  =  =  =.=  is  displayed  in 
main  display,  Hi  Limit  value  is  entered  via  overlay 
numbers,  then  press  “ENTER”  key  to  store  the  Hi 
Limit  value.  =  =  =  =.=  is  displayed  in  main  display, 
Lo  Limit  value  is  entered  via  overlay  numbers,  then 
press  overlay  “ENTER”  key  to  store  the  Lo  Limit 
value and exit SET mode. 

9.4 When the thermometer is turned on it uses the relative 

value and Hi/Lo Limits values that were entered when 
thermometer was last in use. 

 

10. T1/T2 T1-T2 second display Input Selection 

The  input  selection  indicates  which  input  is  selected  for 
second  display;  T1  probe,  T2  probe  or  the  difference 
between  the  two  probes  (T1-T2),  when  the  thermometer 
is  turned  on,  it  is  set  to  T2  input  can  select  alternate  of 
probe  by  second  display  Pt385/Pt3926/Pt3916  key 
switch. 

11. TYPE(Pt385/Pt3926/Pt3916) Input RTD 

Probe select (second display) 

The Pt385/Pt3926 key switches the T2 input to select the 
Pt385, Pt3926 or Pt3916 RTD probe as input, when sec-
ond  display  input  selected  T2.  When  the  thermometer  is 
turned  on,  it  is  set  to  the  RTD  selected  that  was  in  use 
when the thermometer was last turned off. 
 

12. Hi/Lo Limits mode (only Main display) 

Press “Hi/Lo Limits” key to enter the Hi/Lo Limits com-
parative  mode.  When  the  input  temperature  value  ex-
ceeds the Hi or Lo  Limits value, the beeper emits a con-
tinuous or pulsed tone. Press “Hi/Lo Limits” key again to 
exit the Hi/Lo Limits mode. 
 

13. WIRELESS MODE: 

Press  the  “ ”  key  for  more  than  two  seconds  to  start 
wireless  function.  Press  the  “ ”  key  again  for  another 
two seconds to stop wireless function. The wireless mode 
will shut down if there is no wireless signal for two min-
utes. 
To  SET  CH/ID  to  00,00,  press  the  “Hi/Lo  Limits”  key 
and  “

”  power  key for  more  than  6  seconds  with  the 

meter powered down. The meter will set channel and ID 
to  00,00  status.  The  second display  will  show  00,  which 
means that the channel and ID has been set to 00. 

To check the channel and ID of the meter: 
When the meter is off, press “°C/°F” key and “

” for 5 

seconds, LCD’s main display will show channel number, 
the second display will show ID number. 

Отзывы: