d)
Using a 0-5VDC Output Power Adapter Package.
An optional 0-5VDC Output Power Adapter Package is available for use
with the FLR 1000 series (not the FLR 1000-ST-I). This consists of a power
source (115VAC or 230VAC) and cable assembly with pig-tail (soldered
wire) ends for the signal output. This should be assembled as shown in
the following diagram.
Connecting the Power Adapter to the Flow Sensor
(FLR 1000 shown, other models similar)
The 0-5VDC analog output may be connected to a display, data acquisition
system or voltmeter with a minimum load of 2.5 k
Ω
(kilo ohms).
The
YELLOW
wire of the cable assembly provides the 0-5VDC signal
output and should be connected to the positive terminal of the display,
data acquisition system or voltmeter.
The
GREEN
wire is not used.
The
WHITE
wire of the cable assembly is the signal negative and should
be connected to the negative (ground) terminal of the voltmeter, display
or data acquisition system.
Caution: Avoid high voltage static discharges to any of the
connections. Do not short the output signal wires or allow them
to contact the power wires at any time. DAMAGE WILL RESULT!
Содержание FLR 1000 Series
Страница 1: ...FLR 1000 1000 BR Series Flow Sensors Meters For Gases...
Страница 2: ......
Страница 20: ...pg 20 of 29 FLR 1000 For Gases 2 0 10 0 l min Units 1 4 Acetal Fittings Shown...
Страница 21: ...pg 21 of 29 FLR 1000 For Gases 4 0 20 0 l min To 100 500 l min Units 1 2 Acetal Fittings Shown...
Страница 22: ...pg 22 of 29 FLR 1000 D For Gases 20 200 ml min To 1 0 5 0 l min Units 1 4 Acetal Fittings Shown...
Страница 23: ...pg 23 of 29 FLR 1000 D For Gases 2 0 10 0 l min Units 1 4 Acetal Fittings Shown...
Страница 24: ...pg 24 of 29 FLR 1000 D For Gases 4 0 20 0 l min To 100 500 l min Units 1 2 Acetal Fittings Shown...
Страница 25: ...pg 25 of 29 FLR 1000 BR D For Gases 20 200 ml min To 1 0 5 0 l min Units 1 4 Brass Fittings Shown...
Страница 28: ...pg 28 of 29...
Страница 29: ...M4575 0807 pg 29 of 29...