background image

Page 9

User’s Manual DRF Series

INPUT SIGNAL for POTENTIOMETER

RANGES

0/100 %
0/50 %
0/25 %
0/12.5%
(minimum 8%)

Potentiometer value  min 100Ohms

       max 1MOhm

3 Wire System, 1 Vdc Excitation

INPUT SIGNAL in RESISTANCE

RANGES

0/10 KOhms
0/5 KOhms
0/3 KOhms
0/1.5 KOhms
(minimum 750 Ohms)

2 Wire System, 0.2 mA Excitation

OUTPUT SIGNAL in VDC

RANGES

0/10 Vdc
0/1 Vdc

Max Output

11Vdc approx.

Min Output

-1Vdc approx.

Min  Load R

1KOhm

OUTPUT SIGNAL in mA

RANGES

0/20mA (4/20mA)

Max Output

22mA approx.

Min Output

-1.5mA approx.

Max Load R

400 Ohms

POWER SUPPLY

DC Power

24Vdc ±10%

AC Power

230Vac ±10% 50/60 Hz
115Vac ±10% 50/60 Hz

Consumption

<3.8VA

MECHANICAL DIMENSIONS

DC Units

22.5 x 93 x 110 mm

AC Units

37.0 x 93 x 110 mm

Weight DC

120 gr.

Weight AC

200 gr.

TECHNICAL DATA : Models DRF-POT and DRF-RES

Standard DIN rail mounting, as specified
on DIN46277 and DIN EN 50022
37.5 x 7.5 mm 

(1.38 x 0.3 ´´)

GALVANIC ISOLATION LEVELS

DC Units

Input - Output

3.5 KV 

(60 seconds)

Power-Input

3.5 KV 

(60 seconds)

Power- Output 1 KV

(60 seconds)

AC Units

Input - Output

3.5 KV  

(60 seconds)

Power- Input

3.5 KV 

(60 seconds)

Power - Output 3.5 KV 

(60 seconds)

All isolation levels are tested during a time
of 60 seconds, with current leaks <1mA

Note : Indicated isolation levels are also
sometimes named as STRENGTHENED
ISOLATION levels, for systems with
Polution Level 2

GENERAL SPECIFICATIONS

Accuracy

<0.2% F.S.

Optimized for

12 bit systems

Linearity

<0.1% F.S.

Thermal Drift

<250 ppm/ºC Tipical

Warm-Up Time 5  minutes
Response Time <70mS

(90% of signal)

Plug-In Screw Terminals
Maximum Wire Section 2.5 mm

2

Protection

 IP-30

Temp.Operation from 0 to 60ºC
Temp.Storage

from -20 to +70ºC

MATERIALS

Box and Cover in Poliamide PA6 UL94
V-2 blue color
Terminals in  Poliamide UL94 V-0

Содержание DRF-POT

Страница 1: ...omega com e mail info omega com For latest product manuals omegamanual info Shop online at DRF POT FOR POTENTIOMETER INPUT DRF RES FOR RESISTANCE INPUT DRF Series Signal Conditioners User sGuide...

Страница 2: ...cques Cartier 78280 Guyancourt France Tel 33 0 1 61 37 2900 FAX 33 0 1 30 57 5427 Toll Free in France 0800 466 342 e mail sales omega fr Servicing Europe U S A and Canada Sales Service 1 800 826 6342...

Страница 3: ...mance To prevent electrical or fire hazard do not expose the unit to excessive moisture Do not operate the unit in the presence of flammable gases or fumes such an environment definetely constitutes a...

Страница 4: ...The decoupling created between the circuits avoids pernicious effects on the output such as groundloopsorsignalleaks whichdistort the acquired data and are extremely difficulttoisolateonceintroducedin...

Страница 5: ...euppersideof the instrument This terminal is placed in atransverseaxis differentfromtheother terminals Close to the power supply terminal there is a small yellow label with indicationsontheconnections...

Страница 6: ...F RONT VIEW WITHOUT COVER SELECTIONJUMPERS OUTPUT SIGNAL SPANP OTENTIOMETER OFFSET POTENTIOMETER Selection Jumpers Input Signal Range See next page SELECTIONJUMPERS INPUT SIGNAL getting an output whic...

Страница 7: ...NAL RANGE Range 100 FS Range 25 FS Range 50 FS Range 3 KOhms Range Min 1 5 KOhms Range 1 5 KOhms Range Min 750 Ohms Range 5 KOhms Range Min 3 KOhms Range 10 KOhms Range Min 5 KOhms DRF POT for POTENTI...

Страница 8: ...DRF Series Input Connections POTENTIOMETER RESISTANCE 9mm 0 35 93mm 3 66 24 Vdc 0 Vdc 110 mm 4 33 DIMENSIONS AND CONNECTIONS Special Width for AC Power models AC Powered DC Powered Output Connections...

Страница 9: ...Models DRF POT and DRF RES StandardDINrailmounting asspecified onDIN46277andDINEN50022 37 5 x 7 5 mm 1 38 x 0 3 GALVANICISOLATIONLEVELS DCUnits Input Output 3 5 KV 60 seconds Power Input 3 5 KV 60 se...

Страница 10: ...l the unit far from elements generating electric noise or magnetic CAUTIONS WARNINGSANDNOTES fields such as power relays electrical engines speed regulators etc Do not use until installation is comple...

Страница 11: ...per specification misapplication misuse or other operating conditions outside of OMEGA s control Components in which wear is not warranted include but are not limited to contact points fuses and triac...

Страница 12: ...ty Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial...