TECHNICAL DETAILS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model 

OAPC41W 

Fan Speeds 

3 settings 

Cooling Capacity 

14000 Btu/h (4.10 KW) 

Cooling Rated Input Power 

1.560KW 

Cooling Rated Input Current 

6.9A 

Power Supply 

220-240V/50Hz-60Hz 

Refrigerant 

R290 , 0.27Kg 

IP Code 

IPX1 

MAXIMUM SUCTION/EXHAUST 

SIDE WORKING PRESSURE 

0.7MPa/3.2MPa 

Maximum permissible 

pressure on the high/low 

pressure side 

3.2Mpa 

Heat exchanger maximum 

allowable pressure 

3.2Mpa 

Sound Power Level 

65dB(A) 

Net Weight 

31Kg 

Dimensions 

470x353x762mm 

Содержание OAPC41W

Страница 1: ...OMEGA ALTISE OPERATION MAINTENANCE AND SAFETY INSTRUCTIONS FOR OMEGA ALTISE AIR CONDITIONER Model OAPC41W...

Страница 2: ...LTISE Contents IMPORTANT SAFETY INSTRUCTIONS 3 TECHNICAL DETAILS 8 FEATURES 9 PRODUCT OVERVIEW 9 INSTALLATION INSTRUCTIONS 10 OPERATING INSTRUCTIONS 14 CLEANING 18 SERVICING 20 TROUBLESHOOTING 22 WARR...

Страница 3: ...gns of product malfunction Do not clean the appliance with any chemicals Ensure the unit is far away from fire inflammable or explosive objects The unit shall be installed in accordance with national...

Страница 4: ...e shall be stored in a well ventilated area where the room size corresponds to the room area as specified for operation WARNING Do not use means to accelerate the defrosting process or to clean other...

Страница 5: ...om a leak Cabling Check that cabling will not be subject to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental effects The check shall also take into account th...

Страница 6: ...lowed Ensure that contamination of different refrigerants does not occur when using charging equipment Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in t...

Страница 7: ...omplete with pressure relief valve and associated shut off valves in good working order Empty recovery cylinders are evacuated and if possible cooled before recovery occurs The recovery equipment shal...

Страница 8: ...ion systems or contact the retailer where the product was purchased They can take this product for environmentally safe recycling TECHNICAL DETAILS Model OAPC41W Fan Speeds 3 settings Cooling Capacity...

Страница 9: ...shut off when tank full Automatic restart in the event of power outage Auto defrosting function at low ambient temperatures Remote control 3 speed fan Casters for easy mobility PRODUCT OVERVIEW 1 Cont...

Страница 10: ...S Unpacking Unpack the carton and take the appliance and accessories out Check the device after unpacking for any damage or scratches on it Accessories 1 Exhaust hose 2 Hose connector 3 Window kit ada...

Страница 11: ...radiators heat registers stoves or other products that produce heat II Direct sunlight III Mechanical vibration or shock IV Excessive dust V Lack of ventilation such as cabinet or bookcase VI Uneven...

Страница 12: ...kit the length of your window Connect the exhaust hose to the window kit Step 4 Close your window to secure the kit in place It needs to hold the windows kit firmly in place secure the window kit wit...

Страница 13: ...the hose connector to the exhaust air outlet of unit Step 6 Adjusting the length of the flexible exhaust hose and avoid bends in the hose Then place AC near an electrical outlet Step 7 Adjust the lou...

Страница 14: ...Increasing the desired temperature 16 32 or timer setting 5 SWING Adjust the air flow direction vertically 6 TIMER Sets a time for the unit to automatically start or stop 7 FAN Press to switch the fa...

Страница 15: ...tional on the remote control COOLING MODE Select the cool mode to lower the temperature in your room Press MODE button repeatedly until the LED of COOL operation lights up Press ADD MINUS button to ad...

Страница 16: ...e control the LED of DRY operation lights up The fan speed is unable to select User should connect the hose to the drain outlet at the bottom of the unit Note In this mode the fan speed switches over...

Страница 17: ...e self evaporating system uses the collected water to cool the condenser coils for better efficient performance There is no need to empty the drainage tank in cooling operation except in drying operat...

Страница 18: ...cleaning The air filter is removable for easy cleaning Do not operate the unit without an air filter or the evaporator may be contaminated 1 Press POWER button to switch off the unit and unplug the po...

Страница 19: ...on equipment PPE 4 Evacuate unnecessary personnel isolate and ventilate area 5 Do not get in eyes on skin or on clothing Do not breathe vapours or gas 6 Prevent entry to sewers and public waters 7 Sto...

Страница 20: ...n system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion...

Страница 21: ...e safety then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with If the fault cannot be corrected immediately but it is necessary to continue operation an ade...

Страница 22: ...re transport Check if the drain hose is kinked or bends Straighten the hose to avoid a trap existing Excessive Noise Check if the unit is securely positioned Place the unit on horizontal and firm grou...

Страница 23: ...ed to a warranty of Twelve 12 months covering all parts with Three 3 months on any labour cost of service or repair WHAT IS COVERED By Our Warranty During the warranty period Omega Altise or its autho...

Страница 24: ...OMEGA ALTISE A division of Shriro Australia Pty Ltd 2 34 Davidson Street Chullora NSW 2190 In Australia 1300 795 572 In New Zealand 09 415 6000 www omegaaltise com IM Ref OAPC41W 2021 09 02 24...

Отзывы: