WOSm - Installation and operating manual
6
Installation
Unpack the device
Fill the filter element with clean water!
WOSm separator is optimized for mounting on the wall and therefore wall mounting
bracket is included. (wall mounting screws are not included)
Make sure that you have easy access to the device and that there is enough space to
unscrew and remove filter element.
Fix the cyclonic chamber to wall mounting bracket (4 screws M4x10 DIN912 are
included).
Change the housing O-ring.
Remove plastic cap from the filter element and tighten cartridge to the cyclonic
chamber (make sure that o-rings are in appropriate position).
Connect device to the system. At least 10% outlet pipe/hose slope recommended.
Trapped air prevents condensate to flow into or out of the WOSm separator. During
installation ensure that no water pockets are formed in the inlet/outlet pipe/hose.
Outlet must be connected to the sewage system.
Warning
It is strongly recommended to fill the device with clean water at least 24h (we recommend
to fill water into cartridge 1 day before installation/service) before you start to drain
condensate into the separator. If you start to drain condensate into an empty device, filter
element
can get saturated instantly or efficiency may be decreased.