Unpack the device 

 

Fill the filter element with clean water! 

 

WOSm separator is optimized for mounting on the wall and therefore wall mounting 
bracket is included. (wall mounting screws are not included) 

 

Make sure that you have easy access to the device and that there is enough space to 
unscrew and remove filter element. 

 

Fix the cyclonic chamber to wall mounting bracket (4 screws M4x10 DIN912 are 
included). 

 

Change the housing O-ring. 

 

Remove plastic cap from the filter element and tighten cartridge to the cyclonic 
chamber (make sure that o-rings are in appropriate position). 

 

Connect device to the system. At least 10% outlet pipe/hose slope recommended. 
Trapped air prevents condensate to flow into or out of the WOSm separator. During 
installation ensure that no water pockets are formed in the inlet/outlet pipe/hose. 

 

Outlet must be connected to the sewage system. 

 

 

Warning

 

It is strongly recommended to fill the device with clean water at least 24h (we recommend 
to fill water into cartridge 1 day before installation/service) before you start to drain 
condensate into the separator. If you start to drain condensate into an empty device, filter 

element

 can get saturated instantly or efficiency may be decreased.  

 

 

Содержание WOSm Series

Страница 1: ...g manual WOSm water oil separator Please read the following instructions carefully before installing separator housing unit into service Trouble free and safe operating of the unit can only be guaranteed if recommendations and conditions stated in this manual are respected ...

Страница 2: ...WOSm Installation and operating manual 2 Components Part 1 Filter head 2 Inlet connection 3 Outlet connection 4 Wall mounting bracket 5 Filter cap 6 O rings 7 Filter element 1 2 3 4 5 6 7 ...

Страница 3: ...ssive not suitable for emulsion Nr of inlet connections 1 1 Nr of outlet connection 1 1 Connection type Push in fitting for hose diameter 8mm Residual oil content 20ppm Service interval When first of the following parameters appears 4000 operating hours of compressor 2 12 months regardless compressor operating hours All white polypropylene filling becomes yellow adsorbed oil DIMENSIONS A mm 475 81...

Страница 4: ...and Installation and operating manual for those ad ons Maximum temperature and pressure for assembled system is the lowest of any individual part The medium used may not have any corrosive components that could attack the materials of the separator in a way that is not permitted Do not use the separator in hazardous areas with potentially explosive atmospheres All installation and maintenance work...

Страница 5: ... or unreasonable use Use genuine spare parts only Any damage or malfunction caused by the use of ungenuine parts is not covered by Warranty or Product Liability Advanced dimensioning For advanced dimensioning please use following equations Oil carry over c can be determined by measuring oil volume at two sequential compressor services In order to determine oil carry over compare initial volume of ...

Страница 6: ...and tighten cartridge to the cyclonic chamber make sure that o rings are in appropriate position Connect device to the system At least 10 outlet pipe hose slope recommended Trapped air prevents condensate to flow into or out of the WOSm separator During installation ensure that no water pockets are formed in the inlet outlet pipe hose Outlet must be connected to the sewage system Warning It is str...

Страница 7: ...aper For test set please contact us or your local distributor To replace filter element follow this steps Remove plastic cap from NEW filter element fill the cartridge with clean water and close it back with plastic cap Please pay attention to warning specified in INSTALLATION chapter The housing O ring should also be changed at the same time the filter is changed Close condensate inlet or make su...

Страница 8: ...s operated when it was clearly defective Non original spare parts or replacement parts were used The unit was not operated within the permissible technical parameters Unauthorised constructional changes were made to the unit or if parts of the unit that may not be opened were dismantled OMEGA AIR d o o Ljubljana Cesta Dolomitskega odreda 10 SI 1000 Ljubljana Slovenia Tel 386 0 1 200 68 00 Fax 386 ...

Отзывы: