WOSm - Installation and operating manual
3
Technical data
Size
Cold climate zone
15°C 60%RH
Mild climate
zone 25°C 60%RH
Hot climate zone
40°C 100%RH
WOSm1
740
650
370
Max oil adsorption[g]
1,23/43,05
1,08/37,8
0,62/21,9
Max FAD [Nm
3
/min]/[scfm]
0,57
0,90
1,91
Max condensate flow [l/h]
(1)
WOSm2
1520
1340
770
Max oil adsorption[g]
2,54/88,9
2,23/78,05
1,28/45,2
Max FAD [Nm
3
/min]/[scfm]
1,19
1,87
3,96
Max condensate flow[l/h]
(1)
(1)
Max condensate volume per condensate drain single discharge is 0,125 ltr.
WOSm-1
WOSm-2
Operating
temperature range
1,5 - 45 °C (max. 65°C)
[2]
35 - 113 °F (max. 149 °F)
[2]
Operating media
Condensate (air, water, oil); non-aggressive; not
suitable for emulsion
Nr. of inlet
connections
1
1
Nr. of outlet
connection
1
1
Connection type
Push-in fitting for hose (diameter 8mm)
Residual oil content
< 20ppm
Service interval
When first of the following parameters appears:
-
4000 operating hours of compressor
(2)
-
12 months regardless compressor operating hours
-
All white polypropylene filling becomes yellow
(adsorbed oil)
DIMENSIONS
A [mm]
475
810
B [mm]
106
106
C [mm]
80
80
D [mm]
335
670
E [mm]
50
50
[2]Max. operating temperature is 65°C, but when temperature is over 45°C, performance may decrease.
MATERIALS
Housing material
Pa6 30% Glass fiber, Aluminium
Transparent part
Acryl
Fittings
Steel, anodized
Sealing
NBR
Filter material
PP (polypropylene), Active carbon
Bonding
Polyurethane
There is Technical datasheet available. For additional technical specification, contact