The  main  mode  of  operation  is  a  water  level  triggered  discharging.  The  valve  opens  when 
water level in EMD12’s tank reaches threshold and it closes back before the tank is empty. 
This way, only condensed water is discharged and no compressed air is lost.  

In  the  timed  venting  mode,  the  valve  is  opened  when  water  level  reaches  threshold,  too. 
Besides,  when  the  valve  is  closed  continuously  for  a  predetermined  period,  it  is  opened 
shortly although there is no water in the tank. During working day, water in EMD12 collects 
rapidly  so  that  venting  period  would  never  expire  and  there  are  no  air  losses.  When 
production  rests,  EMD12  is  opening  its  valve.  But  since  these  discharges  are  short  and 
sparse, air losses are small. The timed venting mode should be used when there is a lot of 
debris  in  condensed  water  and  piping  upward  the  EMD12  could  not  be  inclined  enough. 
Such  situation  is  quite  common  under  pressure  vessels.  It  may  happen  that  air  could  not 
escape from the tank upward the piping and while there is air around water level sensor, the 
EMD12 would never open. In the timed venting mode, the valve is opened after the venting 
period has expired and trapped air is allowed to escape through drainage. Now, condensed 
water can reach water level sensor and EMD12 is opening its valve until all collected water is 
discharged. 

The timed venting mode is disabled initially since  situations when this mode is needed are 
rare. The mode could be enabled through the service network.  

To service network, only types of EMD12 with communication electronics built in could be 
connected.  The  service  network  is  used  for  uploading  data  that  are  collected  in  EMD12 
during  its  operation.  The  data  are  elapsed  hours,  number  of  water  discharging,  current 
water  level  in  the  tank  and  other  data  that  could  help  to  supervise  and  troubleshoot  the 
system.  Through  the  service  network,  some  operating  parameters  of  EMD12  like  venting 
period in timed venting mode could be set. Additionally, valve could be operated remotely. 

Features: 

 

No loss drain 

 

EMD12 could be fixed horizontally or vertically 

 

Strainer is located front of EMD12 so that it could be reached easily 

 

Optional time venting mode of operation 

 

Optional  Alarm/  Warning  output  and  Service  Network  Protocol  for  remote 
surveillance 

 

Elapsed hour counter, valve operating counter and other data collection 

 

Easy replacement of parts due to wear 

 

Содержание EMD12 Series

Страница 1: ...3400598 EMD12_v2 01 OmegaAir_eng Installation and Operating Manual EMD12...

Страница 2: ...ainer where solid parts of debris are intercepted The strainer is located in front of EMD12 so that it could be reached easily In the condensed water leaving the EMD12 there are still small particles...

Страница 3: ...er open In the timed venting mode the valve is opened after the venting period has expired and trapped air is allowed to escape through drainage Now condensed water can reach water level sensor and EM...

Страница 4: ...er tank 7 8 9 Sealing O Ring 14 x 2 0 10 Service Network Connector 11 Screw M3x16 DIN912 12 Washer 3 2 DIN125A 13 Cover 14 Sealing O Ring 100 x 1 5 15 Power Inlet gland 16 Washer 5 3 DIN125A 17 Washer...

Страница 5: ...10VA 8 5W Operating pressure range 0 16 bar 0 232 psi 0 8 bar 0 116 psi Drain capacity 7 bar 101 psi 12 l h 0 007 cfm Operating temperature range 1 5 C 65 C Protection class 54 Inlet connection G 1 2...

Страница 6: ...n and maintenance work may only be carried out when electrical power supply is disconnected Electrical work must always be carried out by qualified electrician Do not exceed maximal operating pressure...

Страница 7: ...horizontally left or vertically right But it must not be rolled aside more than 15 The horizontal position is preferred in case of a lot of debris in condensed water Do not connect several condensed w...

Страница 8: ...gh auxiliary inlet EMD12 has provisions for building an auxiliary inlet where venting could be connected This auxuliary inlet is not implemented in the standard EMD12 Conntact manufacturer for more in...

Страница 9: ...dance 200mA U reverse 0 7V Power Connection 1 24Vac grounded line 2 24Vac 3 PE Conductor Valve Connection 4 PE Conductor 5 Power line 6 Power line Alarm output EMD12A 7 Alarm Warning 9 GND Umax at hig...

Страница 10: ...nect EMD12 after protection device of heavy inductive load like compressor motor left Instead heavy inductive load and EMD12 should be protected separately right After installation or maintenance work...

Страница 11: ...mode In this mode EMD12 opens its valve longer and more frequently and its capacity is doubled When EMD12 is still not able to discharge all the water in 5min it enters alarm mode In alarm mode EMD12...

Страница 12: ...device could be a Service Network Reader SN 10 200 It s a handheld device that allows user to send command messages manually It also comprises a display where answer to command are read In the table i...

Страница 13: ...eset counter 0xBC Water level sensor adjustment data 0xC0 Current working parameters 0xE0 0xF0 Settings 0xE4 Timed Venting valve opened period Values 0 6s 0 8s 1 2s 1 7s 2 4s Timed venting off default...

Страница 14: ...insert and clean it At the same time check integrity of mesh Be careful while cleaning because solid particles in debris may be sharp Clean also O ring sealing and its gland thoroughly Otherwise stra...

Страница 15: ...isible damage on electronics Air leaks through the drain pipe even when EMD is disconnected from power There might be debris in valve or valve may be damaged Check integrity of strainer The valve asse...

Страница 16: ...installation and operating manual was not followed with respect to installation initial commissioning and maintenance The unit was not operated properly and appropriately The unit was operated when i...

Отзывы: