EMD Installation and operating manual
20
www.omega-air.si
Important Service Network command message codes and their meaning
Code
Description
0x80…0x9F
Device data
0x84
Device Name
Manufacturer, manufacturer’s address and other important data.
0xA0…0xBF
Device State
0xA4
Device condition – general
0xA8
Power on counter, Elapsed hours counter
0xAC
Valve operation counter, Timed venting counter
0xB0
Overload timer, Alarm timer
0xB4
Processor events: Brown out counter, Voltage error counter
0xB8
Processor events: Watch dog reset counter, Software reset counter
0xBC
Water level sensor adjustment data
0xC0
Current working parameters
0xE0…0xF0
Settings
0xE4
Timed Venting - valve opened period
Values: 0.6s, 0.8s, 1.2s, 1.7s, 2.4s, Timed venting off (default)
0xE8
Timed Venting - Period to first operating of valve:
Values: 60min, 40min (default), 20min, 10min, 5min
0xEC
Timed Venting - Period between subsequent operating of valve:
Values: 120min, 60min (default), 40min, 20min, 10min
0xF0
Overload duration:
Values: 2min, 5min (default), 10min
0xF4…0xFF
Control
0xFB
Remote triggering of condensed water purging from EMD
Alarm in 24Vdc version – EMD 12
Contrary to ac versions of EMD 12, a dc version of EMD 12 has a built-in relay, which
provides a voltage free contact. It is of NO type and it is closed, when EMD 12 operates
normally.