BF - Installation and operating manual
3
Technical data
SIZES
FILTER
HOUSING
CONN.
SIZE
[DN]
FILTER
ELEMENT
FLOW CAPACITY
DIMENSIONS [mm]
VOLUME WEIGHT
[Nm
3
/h] [scfm]
A
B
C
D
E
[l]
[kg]
BF 0240
80
1 x 76090
1680
989
1145
450
1640 219 157
38
71
BF 0300
100
2 x 76090
3150
1853
1330
560
1780 324 208
100
110
BF 0450
125
3 x 76090
4700
2765
1330
560
1780 324 206
100
115
BF 0600
150
4 x 76090
6300
3706
1360
620
1780 368 241
125
154
BF 0900
150
6 x 76090
9400
5530
1420
680
1810 405 261
168
195
BF1200
200
8 x 76090
12550
7382
1850
792
525
508
-
283
340
BF 1500
200
10 x 76090
15700
9235
1890
918
545
610
-
411
497
BF 1800
250
12 x 76090
18850
11088 1920
955
555
610
-
428
367
BF 2500
250
16 x 76090
25100
14765 2030 1042
685
711
-
614
643
BF 3000
300
20 x 76090
31400
18481 2130 1085
680
711
-
663
656
Fl
ow capacity at 7 bar(g), 20°C
Standard is connection flange EN 1092-1/01 PN16, flange connection ANSI B16.5 is on request.
MATERIALS
Housing material
Carbon steel
Fittings, Screws
Brass, Brass-zinc plated, Steel
Sealing
Aramid fibre with a nitrile rubber
binder
Corrosion protection
(internal)
Epoxy coat
Outside protection
Powder paint coated (Epoxy-
polyester base)
Lubricant
Shell cassida grease RLS 2
CORRECTION FACTORS
To calculate the correct capacity of a given filter based on actual operating conditions, multiply the nominal
flow capacity by the appropriate correction factor(s).
CORRECTED CAPACITY = NOMINAL FLOW CAPACITY x C
OP
[bar]
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
[psi]
29
44
58
72
87
100
115
130
145
160
174
189
203
218
232
C
OP
0,38
0,5
0,63 0,75 0,88
1
1,13 1,25 1,38 1,50 1,63 1,75 1,88 2,00 2,13
Operating temperature -20 - 120
°C
-4 - 248
°F
Operating pressure
0 - 16 bar(g) 0 - 232 psi
A
D
B
C
D
B
E
C
m
in
.
m
in
.
6
5
0
A