Maintenance
Warning
Before maintenance depressurize the device and keep to the
safety rules when working with pressure equipment.
Weekly:
Rotate the "Test" button and manually drain the accumulated condensate until air begins to
blow from the drain. If a significant amount of water (more than 0.5 liters) exits the valve
then the drain must be thoroughly cleaned.
Yearly:
Disassemble drain and clean all components. Do a visual inspection of seals. Removing the
seals from the grooves is not recommended because there is a high probability of damage
when removing. Do not use solvents to clean rubber components.
Service:
It is recommended to clean the reservoir at least once a year. Sealing elements are subject to wear,
which depends on various operating parameters such as pressure, temperature, dirt content, etc. It is
also recommended to change seals.
Spare parts:
Replacement seals are available on demand. Please contact your distributor or manufacturer.