8
Installation
will eventually result in a warmer cabinet temperature.
LOADING PRODUCT
Shelves have been factory-installed for your convenience. Before loading shelves, please be sure that all shelf
clips are completely fastened in their correct locations. It is important that all shelves rest completely level
before stocking your cabinet with product. In order to maintain correct air flow inside the unit, please be sure
to leave two to four(2 to 4) inches of space between the back wall and stored product. Blocking the evaporator
fans will result in a warmer cabinet temperature, and ultimately compressor failure.
DEFROST SYSTEMS
Refrigerator coils are kept below the freezing point(32°F). During compressor down-time, the evaporator fan
continues to circulate air through the evaporator coil. This air circulation raises the coil temperature above the
freezing point, melting any accumulated frost. Run-off water is drained into the evaporator pan and evaporated.
Freezer coils are defrosted electrically. Automatic defrost timers are built-in to the refrigeration system and may
not be adjusted. The defrost timers automatically initiate at pre-set intervals and for a pre-determined duration.
PLEASE NOTE:
Excessive door opening should be avoided in order to maintain cabinet temperature and to
eliminate the possibility of coil freeze-up.
LOADING FOOD PANS
Pizza prep units and sandwich prep units are designed to function with all pans in place, even if some pans are
to be left empty. For maximum food freshness, Fill the pans only with an amount that can be used in a specific
usage period. During non-use, please close the insulated lid cover.
REVERSING THE DOORS (OPTIONAL)
Note: This only applies to the single door units.
Only perform these steps with another person present to ensure the door does not fall over.
1. Open the door.
2. Remove the screws from the top panel, then open the top panel.
3. Remove the screws of the bottom louver, then remove the louver.
4. Unscrew all of the screws from the upper hinge
5. Unscrew all of the screws from the lower hinge and remove the door and hinges.
6. Place the former upper hinge at the bottom of the unit, parallel to where the lower hinge is, do the same
with the former lower hinge except for the top. Screw the hinges into place.
7. Reassemble the door so it is facing the opposite direction.
8. Reassemble the top panel and the lower louver.
9. The door is now reversed.
Содержание RE-CN-0006-HC
Страница 18: ...18 Parts Breakdown Model RE CN 0006 HC 50054 ...
Страница 20: ...20 Parts Breakdown Model RE CN 0011 HC 50056 ...
Страница 22: ...22 Parts Breakdown Model FR CN 0686 HC 50053 ...
Страница 24: ...24 Parts Breakdown Model FR CN 1219 HC 50055 ...
Страница 26: ...26 Model RE CN 0006 HC 50054 Model RE CN 0011 HC 50056 Electrical Schematics ...
Страница 27: ...27 Electrical Schematics Model FR CN 0686 HC 50053 Model FR CN 1219 HC 50055 ...