10
Installation
Operation
WARNING: Use a standard 20 lb. propane cylinder only.
Use this heater only with a propane vapor withdrawal supply system. See chapter 5 of the standard for
storage and handling of liquefied petroleum gas, ANS/NFPA 58. Your local library or fire department should
have this book. A minimum supply pressure of 0.4 P.S.I. is required for the purpose of input adjustment for
propane gas. Storage of an appliance indoors is permissible only if the cylinder is disconnected and removed
from the appliance. A cylinder must be stored outdoors in a well-ventilated area out of the reach of children. A
disconnected cylinder must have dust caps tightly installed and must not be stored in a building, garage or any
other enclosed area. The minimum permissible gas supply pressure of 10 W.C. is required for purpose of input
adjustment. A minimum of 17,000 BTUs per hour is the required input rating for a heater with a rating less than
full. The pressure regulator and hose assembly supplied with the appliance must be used. The installation must
conform with local codes, or in the absence of local codes,with national fuel gas code, ANS Z223.1/NFPA54,
natural gas and propane Installation Code, CSA B149.1, or propane storage and handling code, B149.2.
A dented, rusted or damaged propane cylinder may be hazardous and should be checked by your propane
supplier. Never use a propane cylinder with a damaged valve connection.
The propane cylinder must be constructed and marked in accordance with the specifications for LP gas
cylinders of the U.S. Department of Transportation (DOT) or the standard for cylinders, spheres and tubes for
transportation of dangerous goods and commission, CAN/CSA-B339.
The cylinder must have a listed overfilling prevention device.
The cylinder must have a connection device compatible with the connection for the appliance.
The cylinder used must include a collar to protect the cylinder valve.
Never connect an unregulated propane cylinder to the heater.
•
Do not store a spare LP-gas cylinder under or near this appliance.
• Never fill the cylinder beyond 80 percent full.
•
Place the dust cap on the cylinder valve outlet whenever the cylinder is not in use. Only install the type
of dust cap on the cylinder valve that is provided with the cylinder valve. Other type of caps or plugs may
result in leakage of propane.
LEAK CHECK
WARNING
•
Perform all leak tests outdoors.
• Extinguish all open flames.
Содержание PH-CN-1800-C
Страница 16: ...16 Parts Breakdown Model PH CN 1800 C 43584 Model PH CN 2105 C 43585...