![Omcan PE-BR-0500-V Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/omcan/pe-br-0500-v/pe-br-0500-v_instruction-manual_4510880012.webp)
12
Maintenance
Troubleshooting
stainless steel protection, leave particles that rust and react contaminating the stainless steel. That is why such
products must not be used for cleaning and sanitization. Scrapings made with sharp instruments or similar
must also be avoided. Main substances that cause stainless steel corrosion: dust, grease, acid solutions such
as vinegar, fruit juices, etc., saltern solutions (brine), blood, detergents (except for the neutral ones), common
steel particles, residue of sponges or common steel wool, and also other abrasives.
MAINTENANCE
Maintenance must be considered a set of procedures with the purpose to keep the equipment best operating
conditions, therefore increasing the equipment life and safety.
•
Cleaning.
•
Wiring - Check all wires regarding deteriorate conditions as well as all electric contacts (terminals)
regarding tightening and corrosion.
•
Contacts – ON/OFF switch, emergency button, reset button, electronic circuits etc, check the equipment in
order to assure that all components are correctly working and the equipment operation is normal.
• Installation.
•
Each month check:
- Check the electrical installation.
- Measure the voltage at the socket.
- Measure the working current and match it with the nominal current.
- Check the tightening of all electric terminals to avoid bad contacts.
- Check electric motor shaft clearance.
- Check the wiring for overeating, insulation failures and mechanical damages.
•
Each three month checks:
- Check electrical components such as ON/OFF switch, emergency button, reset button, electronic electric
circuits, overeating, insulation failings, or mechanical damages.
- Check bearings clearances.
- Check retainers, o-rings, v-rings and other seals.
Before requesting any service on your unit, please check the following points. Please note that this
guide serve only as a reference for solutions to common problems.
PROBLEM
CAUSES
SOLUTIONS
The machine does not switch on.
Lack of power.
Check if machine is plugged in
and if there is power in the power
supply source.
Problem with the electric circuits.
Call technical assistance.
Smoke smell or smoke.
Problem in the electric circuit.
Call technical assistance.
Содержание PE-BR-0500-V
Страница 14: ...14 Parts Breakdown Model PE BR 0500 V 46322...
Страница 15: ...15 Parts Breakdown Model PE BR 0500 V 46322...
Страница 18: ...18 Model PE BR 0500 V 46322 Electrical Schematics...