13
Instructions for Field Conversion
result causing property damage, personal injury or loss of life. The qualified service agency is responsible for
the proper conversion. The installation is not proper and complete until the operation of the covered appliance
is checked as specified in the manufacturer’s instructions.
MODELS
PARTS INCLUDED
CE-CN-0305-H
2 × Jet #53 drill
CE-CN-0597-H
4 × Jet #53 drill
CE-CN-0914-H
6 × Jet #53 drill
CAUTION: ENSURE THE GAS SUPPLY IS SHUT OFF AT THE MANUAL SHUT OFF
VALVE BEFORE PROCEEDING WITH THE CONVERSION.
1. Switch off the gas at the main supply valve and allow the unit to cool down before commencing with the
conversion.
2. Lift off the complete grill plate assembly to expose the burners and valves.
3.
Remove the burners by loosening the fastening nuts located under the rear of the burner, lift the rear of the
burner and slide backwards.
4.
The brass orifice located on the end of the control valve may now be loosened and removed using a 1/2”
wrench. Replace with the new orifice from the conversion kit, first applying a small amount of jointing paste
to the threat on the end of the valve, this will ensure a good gas tight seal.
5. Replace with the new orifice from the conversion kit, first applying a small amount of jointing paste to the
thread on the end of the valve, this will ensure a good gas tight seal.
6.
Replace the burner by sliding the open end over the orifice and then locating the M5 stud through the slot
in the support bracket. Secure by replacing the M5 nut.
7. To operate with LP gas the regulator must be changed to operate at 10” WC or use a LP regulator.
8. Prior to connecting the regulator, check the incoming line pressure, as the regulators can only withstand a
maximum pressure of 1/2 PSI (13” WC). If the line pressure is beyond this limit, a step down regulator will
be required. The arrow forged into the bottom of the regulator body shows gas flow direction, and should
point downstream to the appliance.
9. Check for Gas Leaks - A soapy water solution is recommended for locating gas leakage. Matches, candle
flame or other sources of ignition shall not be used for this purpose.
10. Replace the loose fitting grill plate assembly into position.
11.
Fix the conversion rating plate supplied in the kit adjacent to the original rating plate on the rear of the unit.
Fill in the details required on the installation plate and fix to the rear of the unit.
Setting the pilot burner:
When changing from natural gas to LP gas it is necessary to adjust the pilot burner flame as well. This is done
in the following steps:
1. Remove the control knobs from the front of the unit, loosen the screws holding the front panel and remove.
2. The pilot burner valve is positioned to the right of the control valve, a small adjustment screw is located on
the front face of the valve body. This can be turned in or out with a small flat screw driver.
3. Adjust the screw in small increments whilst the pilot flame is burning until a small stable flame is achieved.
4.
Replace the front panel and secure, refit the control knobs.