12
Maintenance
abrasive cleaners or cleaners/sanitizers containing chlorine, iodine, ammonia or bromine chemicals as
these will deteriorate the stainless steel and glass material and shorten the life of the unit.
Daily:
1. Thoroughly clean back, sides, top and front of unit.
2. Clean trivets daily.
Weekly:
1. Clean unit thoroughly. Clean stainless steel or chromed surfaces with a damp cloth and polish with a soft,
dry cloth. A detergent may be used for cleaning. To remove discolorations, use a non-abrasive cleaner.
2. To clean the drip pan. Remove the drip pan by grabbing the handle and pulling it out of the opening in the
front panel. To replace the pan, reverse this procedure.
3. Burner air shutter openings must be kept clean. Main burner ports must be kept clean. To clean burners,
boil them in a strong solution of lye water for 15 to 20 minutes. Then either brush with a wire brush or clean
gas ports with a sharp-pointed metal instrument to insure open ports.
CAUTION: Clean the regulator at least once a month. Make sure the vent opening is open and not
blocked in any way. Failure to do so will cause variations in pressure. Your unit will not function as well
and it could shorten the life of the product.
SERVICE / REPAIR
NOTE: THIS APPLIANCE MUST ONLY BE SERVICED BY AN AUTHORIZED AGENT.
NOTE: Parts protected by the manufacturer or his agent are not to be adjusted by the installer unless
the installer is an authorized service agent.
If you have any questions or problems contact your nearest Service Representative.
REFERENCE
Item Number Model Number
Description
Manufacturer Model
Number
44198
CE-CN-0212-S
Gas Hotplate Step Up 2 Burners
12” / 305mm 60000 BTU ETL
TR-HPSU212M-08
44199
CE-CN-0424-S
Gas Hotplate Step Up 4 Burners
24” / 610mm 120000 BTU ETL
TR-HPSU424M-08
44200
CE-CN-0636-S
Gas Hotplate Step Up 6 Burners
36” / 914mm 180000 BTU ETL
TR-HPSU636M-08