Maintenance
EACH THREE MONTH CHECKS:
• Check electrical components such as ON/OFF switch, emergency button, reset button, electronic electric
circuits, overheating, insulation failings, or mechanical damages.
•
Check bearings clearances.
• Check retainers, O-rings, V-rings and other seals.
CLEANING AND SANITIZING
All the removable parts of the processor shall be clean using water and neutral soap. Find below the
instructions to remove these parts.
IMPORTANT
Never clean the processor when connected to the electric network, switch it off and unplug it.
IMPORTANT
Before to remove the disc chamber make sure the disc is completely stop.
PROCEDURE TO DISASSEMBLE THE PARTS
1. Switch OFF the processor and unplug the cord.
2.
Move away the stomper.
3. Loose the chamber locking handles.
4.
Remove the disc chamber.
5. Remove the disc.
6. Remove the expeller dish.
To assemble back the parts follow the inverse steps.
IMPORTANT
When washing the discs take care with the knifes, do not struck the knifes with hard objects, thus avoiding to
damage them.
CAUTIONS WITH STAINLESS STEEL
The stainless steel may present rust signs, which ARE ALWAYS CAUSED BY EXTERNAL AGENTS, especially
when the cleaning or sanitization is not constant and appropriate. The stainless steel resistance towards
corrosion is mainly due to the presence of chrome, which in contact with oxygen allows the formation of a
very thin protective coat. This protective coat is formed through the whole surface of the steel, blocking the
action of external corrosive agents. When the protective coat is broken, the corrosion process begins, being
possible to avoid it by means of constant and adequate cleaning. Cleaning must always be done immediately
after using the equipment. For such end, use water, neutral soap or detergent, and clean the equipment with
a soft cloth or a nylon sponge. Then rinse it with plain running water, and dry immediately with a soft cloth, this
way avoiding humidity on surfaces and especially on gaps. The rinsing and drying processes are extremely
important to prevent stains and corrosion from arising.
IMPORTANT
Acid solutions, salty solutions, disinfectants and some sterilizing solutions (hypochlorites, tetravalent ammonia