background image

5

Safety and Warranty

before installing, or servicing this equipment.

WARNING: Instructions must be posted in a prominent location. All safety precautions must be taken 

in the event the user smells gas. Safety information can be obtained from your local gas supplier.

CAUTION: These models are designed, built, and sold for commercial use only. If these models are 

positioned so the general public can use the equipment, make sure that cautions, warnings, and 

operating instructions are clearly posted near each unit so that anyone using the equipment will use it 

correctly and not injure themselves or harm the equipment.

GAS PRESSURE

The appliance and it’s individual shutoff valve (to be supplied by user) must be disconnected from the gas 

supply piping system during any pressure testing of that system at test pressures in excess of ½ psi (3.45 

kPa).The appliance must be isolated from the gas supply piping system by closing it’s individual manual shut-

off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ 

psi (3.45 kPa).

WARNING: A factory authorized agent should handle all maintenance and repair. Before doing any 

maintenance or repair, contact your authorized service representative.

SAFETY PRECAUTIONS

DANGER: Warns of imminent hazard which will result in serious injury or death.

WARNING: Refers to a potential hazard or unsafe practice, which could result in serious injury or 

death.

CAUTION: Refers to a potential hazard or unsafe practice, which could result in minor or moderate 

injury or product or property damage.

NOTICE: Refers to information that needs special attention or must be fully understood even though 

not dangerous.

NOTICE: This product is intended for commercial use only. Not for household use.

NOTICE: Local codes regarding installation vary greatly from one area to another. The National Fire 

Protection Association, Inc., states in its NFPA96 latest edition that local codes are “Authority Having 

Jurisdiction” when it comes to requirement for installation of equipment. Therefore, installation should 

comply with all local codes.

1 YEAR PARTS AND LABOUR BENCH WARRANTY

Within the warranty period, contact Omcan Inc. at 1-800-465-0234 to schedule a drop off to either 

an Omcan authorized service depot in the area, or to an Omcan Service warehouse to repair the 

equipment.

Содержание 44198

Страница 1: ...Revised 08 11 2017 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Gas Step Up Hot Plates Models CE CN 0212 S 0424 S 0636 S Items 44198 44199 44200 Instruction Manual...

Страница 2: ...2 13 14 15 Table of Contents Section General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Parts Breakdown Warranty Registration Model CE CN 0212 S Model...

Страница 3: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Страница 4: ...o entrenado en el correcto funcionamiento de esta m quina y sta usando ropa apropiada y autorizada Cualquier modificaci n a la m quina an la la garant a y puede causar da os a las personas usando la m...

Страница 5: ...5 kPa WARNING A factory authorized agent should handle all maintenance and repair Before doing any maintenance or repair contact your authorized service representative SAFETY PRECAUTIONS DANGER Warns...

Страница 6: ...770 x 480mm Number of Burners 2 4 6 BTU PER NAT LP 30 000 Total BTU Hr 60 000 120 000 180 000 W C IN 6 10 Item Number 44198 44199 44200 Note Depth direction includes the regulator s size Safety and W...

Страница 7: ...7 Installation 1 Shut off the main isolation gas valve and follow the lock out tag out procedure 2 Remove the Tray and Trivets 3 Remove the screws and remove all the cast burners...

Страница 8: ...n 4 Remove the Orifice and Replace it Use a 1 2 spanner See the list of Orifice numbers for the appropriate gas type 5 Converting the Gas Regulator a Remove the converter cover from the regulator Use...

Страница 9: ...te open the pilot valve more If the pilot flame appears larger than necessary turn it down and reset burner ignition The pilot flame should be as small as possible but large enough to guarantee reliab...

Страница 10: ...152 mm 6 rear 152 mm 4 floor 102 mm Noncombustible clearances 0 sides 0 mm 0 rear 0 mm 4 floor 102 mm Do not obstruct the flow of combustion and ventilation air under the unit by the legs or behind t...

Страница 11: ...An unexpected flare could cause severe injury Turn off the unit let it cool and use potholders and or gloves to reposition or remove The space between the legs at the bottom admits combustion air DO...

Страница 12: ...to 20 minutes Then either brush with a wire brush or clean gas ports with a sharp pointed metal instrument to insure open ports CAUTION Clean the regulator at least once a month Make sure the vent ope...

Страница 13: ...13 Parts Breakdown Model CE CN 0212 S 44198 Model CE CN 0424 S 44199 Model CE CN 0636 S 44200...

Страница 14: ...3 73108 Back Pipe of Pilot Assembly for TR HPSU424M 08 9 63535 Valve Connection for TR HPSU424M 08 15 72410 Foot for TR HPSU424M 08 4 63533 Orifice Connection Rear for TR HPSU424M 08 10 73113 Pilot V...

Страница 15: ...er online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 www omcan com warrantyregistration html or email to service omcan com Purchaser s In...

Страница 16: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Отзывы: