9
Controller Instructions
7. Manual start/stop defrost: press
button and hold for 6 seconds to defrost or stop defrost.
8. Refrigerant LED: During refrigeration, the LED is on; When the cold room temperature is constant, the LED
is off; During the delay start, the LED flashes.
9. Defrost LED: during defrosting, the LED is on; When it stops defrosting, the LED is off. During the delay
display of defrost, the LED flashes.
• Unauthorized modifications and/or repairs;
•
Use of non original accessories or spare parts;
Exceptional events.
FEATURES OF FUNCTION
•
This temperature controller very reliable and durable. The relay is exclusively for the use of the compressor
load which makes it safer. This way, the control of temperature easy to operate.
•
There is integrated intelligent control.
THE MAIN FEATURES
•
Temperature display (Celsius/Fahrenheit degrees).
•
Temperature control.
•
Illumination control.
•
Manual, automatic defrost by turning off.
•
Time or temperature setting to end defrost.
•
The cold-room sensor temperature can lock during defrost.
•
Parameter sets and value storing.
•
Compressor restart delay.
•
Parameter locking.
•
The factory default resumption.
•
Offset on sensor temperature.
•
Self-testing.
SPECIFICATIONS
•
Power supply: approx. 12V, 50/60Hz.
•
Power consumption <5W.
•
Range of temperature displayed: -45° - 45°C (-40° - 120°F). Accuracy ±1°C (±2°F).
•
Range of set temperature: : -45° - 45°C (-40° - 120°F).
•
Temperature sensor: NTC, double sensors.
•
Output contact capacity for compressor: N.O. approx. 30A/250V, 50/60Hz.
•
Output contact capacity for illumination: N.O. approx. 30A/250V, 50/60Hz.
•
Main controller panel dimension: 78 × 35 × 76 mm.
•
Mounting dimension: 71 × 29 mm.
INDICATOR
Содержание 25825
Страница 13: ...13 Parts Breakdown Model RS CN 0250 25825 ...
Страница 15: ...15 Model RS CN 0250 25825 Electrical Schematics ...
Страница 16: ...16 ...
Страница 18: ...Notes ...
Страница 19: ...Notes ...