background image

12

ASSEMBLY INSTRUCTIONS

A dented, rusted or damaged propane cylinder may be
hazardous and should be checked by your cylinder 
supplier. Never use a propane cylinder with a damaged 
valve connection.

The propane cylinder must be constructed and marked
in accordance with the specifications for LP gas 
cylinders of the U.S. Department of Transportation
(DOT) or the standard for cylinders, spheres and 
tubes for transportation of dangerous goods and 
commission, CAN/CSA-B339.

The cylinder must have a listed overfilling prevention 
device.

The cylinder must have a connection device compatible 
with the connection for the appliance.

The cylinder used must include a collar to protect the 
cylinder valve.

Never connect an unregulated propane cylinder to the
heater.

Screw regulator onto gas hose. Do not cross-thread.
Tighten securely. Attach regulator to cylinder. Complete 
attachment.

Install cylinder, and secure with the propane tank strap
tightly.

 Do not store a spare LP-gas cylinder under or near this appliance;
 Never fill the cylinder beyond 80 percent full;
 Place the dust cap on the cylinder valve outlet whenever the cylinder is not
in use. Only install the type of dust cap on the cylinder valve that is provided with
the cylinder valve. Other type of caps or plugs may result in leakage of propane.

Содержание BFH-A

Страница 1: ...r use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other applia...

Страница 2: ...4 1 1 1 Wheel Assembly Bottom Plate N O I T P I R C S E D T R A P QUANTITY A Reflector 1 B 1 C Upper Glass Tube D Upper Support E Upper Protective Guard F 1 4 4 G H 4 I Black Silicone Ring Lower Prote...

Страница 3: ...following symbols shown below are used extensively throughout this manual Always heed these precautions as they are essential when using any mechanical or fueled equipment DANGER DANGER DANGER indica...

Страница 4: ...heat producing products for specific uses Your local authorities can advise you about these If no local codes exist follow National Fuel Gas Code ANS Z223 1 In Canada installation must conform to loca...

Страница 5: ...Store or use propane gas in compliance with local ordinances and codes or with ANS NFPA 58 Turn off propane when not in use WARNING Alert children and adults to the hazards of high surface temperature...

Страница 6: ...sert the pins of the base to the holes of lower support press to secure the pins Using 4pcs screw M5x10 to secure the lower support and base Insert the pins of the Control Box Assy to the holes of upp...

Страница 7: ...ock belt to the 2pcs of lower support behind the front door using 2pcs screw M5X10 4 Assemble the middle support Insert the 4pcs upper support to the lower support Secure them with 8pcs screw 3 16 x 1...

Страница 8: ...sing 8pcs screw 3 16 6 Assemble the reflector onto the flame screen Screw the 3pcs stud on the flame screen SXW SFV ZDVKHU RQWR WKH WRS RI VWXG then put the reflector onto the stud secure WKHP ZLWK SF...

Страница 9: ...lack silicone ring WARNING The black silicone ring must be in place prior to operating the heater BLACK SILICONE RING Hardware Used 8 8 Hang a lower protective guard onto hooks on the lower supports m...

Страница 10: ...ote Do not cover the front side where the control knob is LL I Hardware Used DD KK x 18 Philips screwdriver 3 16 Screw x 1 10 Install the knob to M4x10 screw Hang the chain to the hole on the control...

Страница 11: ...sible only if the cylinder is disconnected and removed from the appliance A cylinder must be stored outdoors in a well ventilated area out of the reach of children A disconnected cylinder must have du...

Страница 12: ...st have a connection device compatible with the connection for the appliance The cylinder used must include a collar to protect the cylinder valve Never connect an unregulated propane cylinder to the...

Страница 13: ...continue appearing the hose should be returned to the place of purchase 3 If leak is at regulator cylinder valve connection disconnect reconnect and perform another leak check If you continue to see...

Страница 14: ...ly inspected before each use and by a qualified service person at least annually If relighting a hot heater always wait at least 5 minutes 2 Inspect the hose assembly for evidence of excessive abrasio...

Страница 15: ...ed and a waiting period of at least 5 minutes should pass before attempting to light If you experience any ignition problem please consult Troubleshooting on page 19 Caution Avoid inhaling fumes emitt...

Страница 16: ...s are secure and do not leak 5 Wind velocity is below 10 mph 6 Unit will operate at reduced efficiency below 40 F 7 Heater is outdoors outside any enclosure 8 There is adequate fresh air ventilation W...

Страница 17: ...21 More frequent cleaning may be required as necessary It is imperative that control compartment burner and circulating air passageways of the heater be kept clean After Operation 1 Gas control is in...

Страница 18: ...ce of your heater Apply to exterior surfaces from the pole down Do not apply to emitter screen or domes Storage Between uses Turn Control Knob OFF Disconnect LP cylinder Store heater upright in an are...

Страница 19: ...lockage Clean reflector and burner screen Outdoor temperature is less than 40 F and tank is less than 1 4 full Turn cylinder valve OFF and replace cylinder Use a full cylinder Turn control knob to ON...

Страница 20: ...s or damage resulting from the installation removal or transportation of the product will the responsibility of the owner and are not covered by this warranty The owner assumes all other risks arising...

Страница 21: ...Block Belt 4 1 1 1 Wheel Assembly Bottom Plate N O I T P I R C S E D T R A P QUANTITY A Reflector 1 B 1 C Upper Glass Tube D Upper Support E Upper Protective Guard F 1 4 4 G H 4 I Black Silicone Ring...

Отзывы: