SEAT REPLACEMENT:
•
Depressurize the system; ensure that there is no pressure trapped inside the valve.
•
Remove valves bonnet(13) and its subassemblies.
•
Body(18), seat rings, wedge(17) and gland nuts (5) inspected to be clean, free from any residual material and
damaged or scratched.
•
If the wedge (17) is damaged seriously, it should be replaced.
•
If seat rings are seriously damaged, valve must be taken out from the line to be repaired
•
Ask OMB advise for correct seat rings selection according to the working pressure and the valve size.