400715D-EN
12
NOTICE
Do not over or under tighten the nozzle body. Tighten the nozzle body to the specified torque. Under
tightening can cause leaks and equipment damage. Over tightening damages the sealing surface between
the orifice assembly and the nozzle filter assembly. Do not tighten the nozzle body to more than 25 ft-lb
(34 N·m).
6.
Hold the
A-Jet
to counteract the torque, then tighten the
nozzle body
.
Figure 10
7.
Install the
mixing tube
. See
8.
Connect the
abrasive feed tube
to the
nozzle
and the
abrasive hopper
, if needed. Make sure the
abrasive
tube
is inserted through the slot in the
nozzle flap splash guard
.
Figure 11
9.
Recalibrate the
A-Jet
. See
400610 A-Jet Users Guide
.
Install the Nozzle Body on a Motorized Z-Axis
NOTICE
Remove the mixing tube BEFORE installing or removing the nozzle to prevent damage. Large upward
forces from an installed mixing tube can misalign the internal nozzle components.
1.
Remove the
mixing tube
if it is installed in the
nozzle body
NOTICE
Handle the nozzle carefully to prevent damage to the abrasive tubing retention tube.
Содержание MAXJET 5i 320303 Series
Страница 32: ...32 400715D EN...