7 - Start the pump possibly at reduced speed, then increase it till it reaches the duty speed, checking possible troubles
(pressure overload, loss in piping, cavitation, vibration).
8 - If the duty speed is very high, it's normal that the bearing housing temperaturs reaches 50-60
°
C, expecially during
the first working hours.
4. GENERAL MAINTENANCE
4.1 - LUBRICATION
1 - OMAC pumps are delivered ready filled with oil of ISO VG 68.
9
Advised lubricants Tab. 9
Oil quantity Tab. 10
DUTY TEMPERATURE
da –20
°
C a + 90
°
C
da +90
°
C a + 150
°
C
MAKE
ESSO
SHELL
CASTROL
BP
MOBIL
AGIP
FINA
SPARTAN EP 68
OMALA OIL 68
ALPHA SP 68
ENERGOL GR-XP 100
MOBILGEAR 626
BLASIA 68
GIRAN 100
SPARTAN EP 150
OMALA OIL 150
ALPHA SP 150
ENERGOL GR-XP 150
MOBILGEAR 629
BLASIA 150
GIRAN 150
PUMP TYPE
LITER
B100
B105 - B110 - B115
B215 - B220
B325 - B330
B430 - B440
B470 - B490
B550
B660-B680
0,2
0,5
1
2,2
4,5
6,7
15
30
2 - Check every day the oil level arranged on pump side, which must be completly filled with the pump off.
3 - When necessary top up using the lubricant oil as per Tab. 9.
4 - If the pump is used with vertical openings invert the plug position with the oil level.
5 - The oil replacement should be carried out after running-in of about 150 working hours, then after every 2500 hours.
6 - If the bearing housing works constantly with temperatures over 90
°
C, lubricate by means of oil with higher viscosity
(see Tab. 9) and replace it every 1000 working hours.
4.2 - SINGLE BALANCED MECHANICAL SEALS Fig. 23 - 24
1 - The mechanical seals require no maintenance.
2 - If a leakage occurs, because of contact surface wear, replace the complete seal (see disassembling instructions).
3 - In case of long working with worn seals, check the pruduct doesn't enter the bearing housing.
4 - IMPORTANT: Don't work the simple mechanical seals dry.
4.3 - FLUSHED MECHANICAL SEALS Fig. 25
1 - As well as the single mechanical seals, the flushed mechanical seals require no maintenance.
2 - When the mechanical seal is replaced, replace the turning ring (224) and the lip ring (223) of the auxiliary seal
too.
3 - With a well connected flushing, the pump can work even with no product being pumped, because the seals can
not become overheated.
4 - Check the fluxing is efficient during the pump working, in order not to damage the auxiliary seals (see connection
diagram Fig. 9).
5 - To disassemble the flushed mechanical seals, see single mechanical seals instructions.
6 - To remove the stationary part of the mechanical seal, remove the flushing box from the rotor case.
7 - During the assembling, before inserting the rotating part of the mechanical seal, put rightly the turning ring (224)
and assemble the auxiliary sealing ring (223) in its seat on the flushing box (220) according to drawing Fig. 25.
4.4 - SEALS BALANCING
1 - All the mechanical seals of the lobe pumps are balanced, that is with stationary part locked by a special balancing
ring 210 - 230 (Fig. 23 - 24 - 25).
Содержание B Series
Страница 1: ...Installation operation and maintenance manual AUT N 810 EDIZ 07 01 ...
Страница 25: ...25 9 INSTRUCTIONS FOR ASSEMBLY AND DISASSEMBLY PUMP TYPE B6 Fig 16 Cross section type B660 B680 ...
Страница 26: ...26 9 INSTRUCTIONS FOR ASSEMBLY AND DISASSEMBLY PUMP TYPE B550 Fig 16 bis Cross sections type B550 ...
Страница 36: ...36 Fig 21 Safety valve and hand by pass 3 BY PASS SAFETY VALVE ON PUMP COVER ...
Страница 38: ...38 Fig 18 Pump type B105 B110 B115 ...
Страница 39: ...39 Fig 19 Pump type B215 B220 B325 B330 B430 B440 ...
Страница 40: ...40 Fig 20 Pump type B550 B660 B680 ...
Страница 43: ...43 ...
Страница 44: ...44 ...
Страница 45: ...45 ...
Страница 46: ...46 Fig 40 Cross section type B100 ...
Страница 47: ...47 Fig 41 Pump type B100 ...
Страница 50: ...50 ...
Страница 51: ...51 ...