7. Extract the stationary part of the seal from the support
fixed on seal flange.
8. Untighten the socket head screws on mechanical
seal.
9. Extract the rotating part of the seal from the shaft.
ROTOR CASE ASSEMBLY
10. IMPORTANT!
During the following operations, take care you don't
damage the lapped seal surfaces; don't lay them
on the bench and handle them with clean hands.
11. Clean carefully the shafts. Be sure the spacers for
the seals are set (295). Lubricate lightly the O-rings
and insert the rotating part of the seals on the shafts.
Exert pressure only with hands; avoid using metal
tools.
12. Be sure the mechanical seals stand on the shaft
shoulder and tighten by degrees the socket head
screws. We suggest you should use a thread locking
adhesive in order to avoid their untightening on
work.