setting
start
SET
The controller user can modify:
1.
Boost voltage 2.
Load low-voltage protection point
3. Temperature units.
4.
Charging capacity cleared
SET
SET
Short push
Charging capacity cleared
SET
(twinkle)
temperature
units
SET
Technical Date
MODEL
S
NC50
S
N
C60
Max
.
solar
panel
current
50A 60A
Max. load current
50A 60A
Use voltage
12
V
/24
V
,
automatic
recognition
NO
-
load
current
10 mA
Overvoltage protection
15.5V/(12V
system
), 31V/(24V
system
)
Work
temperature range
: -35℃--+55℃
Boost
voltage
14.6V(12V
system
), 29.2V/(24V
system
) (
The default value,it can be set)
Equalization
voltage
14.8V(12V
system
), 29.6/(24V
system
)
Float voltage
13.8V(12V
system
), 27.6V/(24V
system
)
Recharge voltage
13.2V(12V
system
); 26.4/(24V
system
);
Temperature compensation
-5mv/℃/2V
Low-voltage
disconnect
11V(12V
system
); 22
V
/(24V
system)
; (
The default value,it can be set))
Load
reconnect
voltage
12.6V(12V
system
), 25.2
V
/(24V
system
);
Charge
control
mode PWM
diplay mode
LCD
When you are make setting operation, the related number will twinkle.
After you finish the setting, the twinkle will stop and the related number
will save.
hold
5
seconds
boost
voltage
(
)
twinkle
load
low
-
voltage
protection point
(twinkle)
Short push
charging
capacity
(twinkle)
Short push
Reduce
( reduce 0.01V)
the voltage value
increase the voltage value
( increase 0.01V)
Reduce
( reduce 0.01V)
the voltage value
increase the voltage value
( increase 0.01V)
Fahrenheit and Celsius cycle show