Part Names

Operating

Radiator

Terminal Blocks

Button

LCD

shell

Temperature sensor

Charge indicator

load

 

indicator

charge indicator 

green

 

LED

 

ON

charging

 

OFF

no charging

 

ON

:  

Stop output

 

OFF

Output normal

SET

Parameter Browse

SET

SET

Ambient 
temperature

SET

Charging current

Charge capacity

Load current

Load voltage

capacity percent

start

Key Description

SET

Previous

Function key,  cycle display  main menu

Load ON/OFF  

Connecting

            1. Connect sequence 1. 

 --2.

 --3.

            2. Wier size:  50A:   Min10mm

                                   60A:   Min12mm

             3. Grounding the solar system: Be aware that the positive terminals 

               of the SNC controller are  connected internally and therefore have

               the same electrical potential. if any grounding is required ,always

               do this on the  positive wires.

             

loads

battey

 solar array

2

charge indicator 

Red 

 

LED

PV votage

Battery votage

Load  state

Back

Battery

Fuse

F

u

s

e

Fuse

REMARK: Mind the recommendations of your battery 

manufacturer, we strongly recommend connecting a fuse

directly to the battery to protect any short circuit at the battery

wiring. The fuse must take the charge controller nominal current:

SNC50 : 100A

SNC60:  120A