background image

1

2

3

The

 

table

 

below

 

will show you the different causes of inverter stopping

The state<activated> or <deactivated> of the functions is indicated by the buzzer with a continuous push on the on/off key after a duration 

given for each function as per the table below:

Ÿ

single <beep> short=function activated

Ÿ

Double <beep> short = function deactivated

Function

Acoustic alarm

Bttery lifetime optimization
(B.L.O.)

Alarm by voltage flickering

Duration of impulse(onto on/off)

5 seconds

10 seconds

15 seconds

Default setting

Activated

Deactivated

Deactivated

The state is reversed if the on/off key is released within 2 seconds following the buzzer sound. 

To consult the state of functions without having any effect on them or changing their programming it is possible to main the on/off key pushed 

on. Beyond 20 seconds the buzzer will sound continuously to indicate the end of the sequence and willstop by the release of the key

 Safe

The inverter

 

is

 

electronically

 

protected

It

 

is

 

portected

 

against

 

reverse

 

polarity

 

by

 

an

 

internal

 

fuse

,

The

 

nxet

 

table

 

displays

 

the

 

various

 

possible

 

default

 

cases

 

and

 

their

 

cnosequences

Caution

the

 

inverter

 

is

 

not

 

protected

 

against

 

the

 

connection

 

of

 

an

 

AC

 

source

(

generator

 

or

 

grid

at

 

its

 

output

such

 

connection

 

wil

  

cause

 

a

 

major

 

failure

 

and

 

should

 

be

 

avoided

Battery

 

portection

 

by

 

LVD

-

low

 

voltage

 

disconnection

 

battery

 

protection

:

The

 

battery

 

is

 

protected

 

from

 

deep

 

discharge

 

by

 

stopping

 

the

 

inverter

 

if

 

the

 

battery

 

traches

 

a

 

voltage

 

lower

 

than

 0.87

Unom

.(10.5 

or

 21

V

)

during

 

more

 

than

 1 

minute

An

 

accoustic

 

signal

 

or

 

a

 

voltage

 

flickering

(

if

 

authorized

is

 

activated

 

during

 

1

minute

 

before

 

the

 

inverters

 

stops

the

 

inverter

 

must

 

then

 

be

 

restarted

 

manually

it

 

will

 

restart

 

antomatically

 

if

 

the

 

battery

 

voltage

 

is

 

back

 

to

 

a

 

value

 

higher

 

than

 1.04*

Unom

(12.5 

or

25

V

),

the

 

inverter

 

will

 

stop

 

immediately

(

with

 

no

 

delay

if

 

the

 

battery

 

voltage

 

is

 

lower

 

than

 0.75*

Unom

(9 

or

 18

V

).

CAUSE

CONSEQUENCE

SOLUTION

Low battery voltage
voltage<0.87*Unom

Deep discharged
battery voltaeg<0.75*Unom

Overheating

Battery overvoltage 1.33Unom

Short circuit at the output

Overload

Battery reverse polarity

inverter temporary stopped ,the green
 indicator blinks

Inverter stopped

Inverter temporary stopped the green
 indicator blinks

Inverter stopped

Inverter stopped

Inverter stopped

Internal fuse broken down

Automatic restart when the battery 
voltage rises at 1.04*Unom

The inverter should be manually restarted

Inverter should be manually restarted when
 the battery has reached=0.87*Unom

Automatic restart when the temperature
 reaches the normal range

Wait until the battery voltage reaches the correct level

Push the ON/OFF button to reactivate the
 inverter 1.2*Unom

Eliminate the short circuit

Push the ON/OFFbutton to reactivate 
the inverter

Use the inverter only in the range of its 
nominal power. Regular use in overload 
power diminishes the lifetime of the inverter
Push the ON/OFF button to reactivate the inverter

Back to manufacture for testing