7 .
Charging parameters
Battery
type
GEL
Lead
-
acid
(14.4
V
)
AGM
(14.7
V
)
LiFePO4(13.9V)
LiFePO4(14.2V)
LiFePO4(14.4V)
LiFePO4(14.6V)
Lithium-ion(1
2.
6V)
Absorption
Float
14.3V
14.4V
14.7V
13.9V
14.2V
14.4V
14.6V
12.6V
13.8V
13.5V
13.5V
13.8V
13.8V
13.8V
13.8V
12.5V
Note: 24V charger, multiply all parameters by 2
8 .
Optional accessories
8.1
Temperature sensor
(
RTS
)
8.2 Monitor(MT-2)
Display battery voltage, charging current,
charging AH, charging WH
8.3
Bluetooth
dongle
Connect the mobile phone app (chargerconnect) to display the
battery in real timeVoltage, charging current, charging AH,
charging WH, and fault information
Specification: NTC 10K
measure the externalenvironment temperature, for lead-acid batteries
Temperature compensation for charging parameters,
compensation value; 18mV/
℃
(12V)
,
36mV/
℃
(24V)
Note: the temperature sensor is not connected, and the charging is
based on the default 25
℃
standard parameter