background image

Vanta — Getting Started Guide

EN-5

Transportation of lithium-ion batteries is regulated by the United Nations under the United 
Nations Recommendations on the Transport of Dangerous Goods. It is expected that 
governments, intergovernmental organizations, and other international organizations shall 
conform to the principles laid down in these regulations, thus contributing to worldwide 
harmonization in this field. These international organizations include the International Civil 
Aviation organization (ICAO), the International Air Transport Association (IATA), the 
International Maritime Organization (IMO), the US Department of Transportation (USDOT), 
Transport Canada (TC), and others. Please contact the transporter and confirm current 
regulations before transportation of lithium-ion batteries.

For California (USA) only:
The CR battery contains perchlorate material, and special handling may be required. Refer to 
http://www.dtsc.ca.gov/hazardouswaste/perchlorate.

Do not open, crush, or perforate batteries; doing so could cause injury.

Do not incinerate batteries. Keep batteries away from fire and other sources of extreme heat. 
Exposing batteries to extreme heat (over 80 °C) could result in an explosion or personal injury.

Do not drop, hit, or otherwise abuse a battery, as doing so could expose the cell contents, which 
are corrosive and explosive.

Do not short-circuit the battery terminals. A short circuit could cause injury and severe damage 
to a battery making it unusable.

Do not expose a battery to moisture or rain; doing so could cause an electric shock.

Only use the Vanta analyzer or an external charger approved by Olympus to charge the batteries.

Only use batteries supplied by Olympus.

Do not store batteries that have less than 40 % remaining charge. Recharge batteries to between 
40 % and 80 % capacity before storing them.

During storage, keep the battery charge between 40 % and 80 %

Do not leave batteries in the Vanta analyzer during instrument storage.

Electrical Warnings

The instrument must only be connected to a power source corresponding to the type indicated on the 
rating label. 

If an unauthorized power supply cord is used to power the instrument or charge the batteries, 
Olympus cannot guarantee the electrical safety of the equipment. 

X-ray tubes and detectors in this instrument contain beryllium metal in the form of coated foil. In 
its as-supplied state, the beryllium poses no harm to the user. However, if a detector or tube is 
damaged, contact with small particles is possible if the instrument is breached (for example, a 
window is broken or during window replacement). Intact skin is sufficient protection against this 
situation and washing with soap and water will effectively remove any beryllium contamination. 
If granulated beryllium embeds in an open wound, seek medical attention. 

Instruments with a damaged detector or tube must be returned to your local distributor or the 
manufacturer. Care should be taken to limit the release of beryllium from the instrument.

Equipment Disposal

Before disposing of the Vanta analyzer, check your local laws, rules, and regulations, and follow them 
accordingly.

CAUTION

CAUTION

Содержание Vanta C Series

Страница 1: ...tion Safety Signal Word Indicates a potentially hazardous situation and calls attention to a procedure practice or the like which if not correctly performed or adhered to may result in minor or modera...

Страница 2: ...lled in the analyzer It is also used to power the docking station To Charge the Battery Plug the DC power plug of the AC power adaptor into the DC power socket of the Vanta analyzer The Vanta charges...

Страница 3: ...the handle 2 Pull the handle end out to remove the current battery 3 Align the contacts of a fully charged battery with the contacts in the Vanta handle and then insert the battery into the handle Th...

Страница 4: ...2 Read the radiation safety notice 3 In the password area four blank boxes tap the leftmost box to display the keypad 4 Enter the password to confirm that you are a certified user To Power Off the Ana...

Страница 5: ...e Do not expose a battery to moisture or rain doing so could cause an electric shock Only use the Vanta analyzer or an external charger approved by Olympus to charge the batteries Only use batteries s...

Страница 6: ...ltration using a 316 stainless steel target Note that these beam conditions do not represent typical use values or a combination of settings typically available from the factory To convert from Sv h t...

Страница 7: ...Page intentionally left blank...

Страница 8: ...Printed in the United States of America Copyright 2016 2019 2020 by Olympus All rights reserved International edition Part ID Q0200572 Q0200572 Printed on Rolland Hitech50 which contains 50 post consu...

Отзывы: